KM

lp -
Help for Webmasters « back to results for ""
Below is a cache of http://www.kmsystemsinc.com/DRAWINGS/1100/PDFs/1100-Specs.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
KM
KM
AUTOMATED ENTRANCE SYSTEMS
KM
SYSTEMS, INC.
4910 STARCREST DRIVE (28110)
P.O. BOX 3099
MONROE, NC 28111-3099 PH. 1-800-438-1937




3/03
AUTOMATIC SLIDING DOORS
ARCHITECTURAL SPECIFICATIONS
SERIES 1100 ULTRA-GLIDE
SLIDING ENTRANCES
11-3.01
PART 1: GENERAL

1.01 S
COPE

This specification details the requirements for the fabrication and installation of automatic sliding doors. Door
packages shall be complete including sliding door(s), sidelite(s) [filler tube(s) on surface mounted units], side
jambs, header with roller track, operator, bottom door guides, and activation devices. (Optional transom would
also be included with this package).
1.02 R
ELATED
W
ORK

The following exclusions are covered in Section(s) ___________:
1. Preparation of the plumb and square masonry opening
2. Floor preparation
3. Electrical supply and connection (dedicated 120 VAC, 15 amp circuit to each operator/header)
1.03 Q
UALITY
A
SSURANCE

Door packages to be provided by authorized distributor of
KM SYSTEMS, INC.
Provide automatic sliding door
package(s) that meet the requirements of the following standards:
ANSI/BHMA A156.10: American National Standard for Power Operated Doors
UL Standard 325: Standard for Electric Door, Drapery, Gate, Louver, and Window Operators and
Systems
1.04 S
UBMITTALS

Installing
KM SYSTEMS, INC.
distributor shall provide the following submittal information:
1. Product Data: Submit
KM SYSTEMS, INC.
product data and standard details.
2. Shop Drawings: Submit five prints and one reproducible shop drawing for fabrication and installation
approval.
3. Templates and diagrams: Submit templates, wiring diagrams, fabrication details, and other information
to providers of related work to coordinate the proper installation of the automatic doors.
1.05 W
ARRANTY

Door packages shall be warranted against defect in material and workmanship for a period of one year from the
date of installation.

PART 2: PRODUCT

2.01 M
ANUFACTURER

Series 1100 Ultra-Glide sliding door packages as detailed shall be supplied by
KM SYSTEMS, INC.
, Monroe,
NC.
2.02 D
ESIGN

A. SLIDING DOOR PACKAGE: Sliding door packages shall be complete including operator, sliding door(s),
sidelite(s)
[filler tube(s) on surface mounted units], side jambs, headers with roller track, bottom door
guides, and activation devices.
B. DOORS AND FRAMES: All structural aluminum sections shall be 6063-T5 alloy with exposed surfaces
anodized (painted) to matching architectural finish. Extruded aluminum header and cover shall conceal
continuous roller track, nylon polymer track cap, and anti-derail extrusion. Track and cap shall be
replaceable without replacing or removing header. Door carrier assemblies shall incorporate four steel,
precision, sealed ball bearing rollers and Grade 8 alloy steel hanger bolts. Concealed bottom door guides
shall provide stable movement of sliding panels. Narrow stile door and sidelite construction shall utilize 1¾
(44 mm) deep x 2 (51 mm) wide vertical profiles and 3½ (89 mm) bottom rails [medium stile door and
sidelite construction shall utilize 1¾ (44 mm) deep x 3½ (89 mm) wide vertical profiles and 6 (152 mm)
bottom rails]. Wool weather pile shall run full height at front of sliding door(s), back of sidelite(s), and
between the door(s) and sidelite(s) [filler tube(s) on surface mounted units]. Units shall be one of the
following configurations:

/CONTINUED

M
AUTOMATED ENTRANCE SYSTEMS
K
KM
SYSTEMS, INC.
4910 STARCREST DRIVE (28110)
P.O. BOX 3099
MONROE, NC 28111-3099 PH. 1-800-438-1937




3/03


AUTOMATIC SLIDING DOORS

ARCHITECTURAL SPECIFICATIONS


SERIES 1100 ULTRA-GLIDE
SLIDING ENTRANCES

11-3.01

2.02 D
ESIGN C
ONTINUED

NF (O-SX, SX-O, O-SX-SX-O)
NF TELESCOPE (O-X-SX, SX-X-O, O-X-SX-SX-X-O)
NP (SO-SX, SX-SO, SO-SX-SX-SO)
NP TELESCOPE (SO-SX-SX, SX-SX-SO, SO-SX-SX-SX-SX-SO)
SF (P-SX, SX-P, P-SX-SX-P)
SF TELESCOPE (P-X-SX, SX-X-P, P-X-SX-SX-X-P)
PP (SO/SO-SX, SX-O/SO, O/SO-SX-SX-SO/SO)
SA (P/SO-SX, SX-SO/P, P/SO-SX-SX-SO/P)
SR (P-SX, SX-P, P-SX-SX-P)
Side jambs and transom framing shall be 1¾ (44 mm) x 4½ (114 mm). Optional 1 (25 mm) x 4½ (114
mm) and 4½ (114 mm) x 4½ (114 mm) side jambs are also available.

C. O
PERATOR
:
Door movement shall be driven by a sealed, brushless DC gearmotor and nylon
reinforced drive belt. The multifunction microprocessor control shall provide fully adjustable open,
close, and check speeds. An adjustable hold open time delay (1-60 seconds) shall be provided. The
microprocessor shall provide a safety-first recycle/stop feature if closing/opening is obstructed. The
control shall provide self-monitor system that compensates each cycle for changes in temperature,
wind load, pressure and mechanical drag and checks for proper internal operation. The control shall
adjust motor speeds, checking action, and other operating characteristics. An ON/OFF switch and
resettable circuit breaker shall be provided. The system shall be provided with a reduced opening
feature that allows a field setting of the reduced opening width. The reduced opening can be constant
or as a function of traffic frequency. Selectable ratchet mode shall keep the door in the open position
until a second activation signal. After receipt of a second activation signal, the door shall close. The
operator shall allow the door to be opened manually in power off conditions. Optional battery pack
shall automatically either open or close the door(s) after power is lost.
D. E
MERGENCY
E
GRESS
Sliding door(s) and swing-out sidelites (on units so equipped) shall be capable of
being swung out to 90° from any position of slide movement (except for SR units) and require no more
than 50 lbf. (222 N) of force applied at the lock stile to open. Units with this emergency egress feature
comply with Chapter 5, Means of Egress, of the Code for Safety from Fire in Buildings and Structures,
ANSI/NFPA 101.
E. S
ECURITY
:
The sliding doors shall be fitted with a Maximum Security hookbolt deadlock. Biparting
units shall include a threshold bolt for two-point locking. Units with swing-out sidelites shall
incorporate mechanical interlocks between the sliding door(s) and sidelite(s) to guard against forced
entry when the unit is locked. (Option: Unit can be provided with either a fail-safe or fail-secure electric
lock concealed in the header and coordinated with the operator to electrically lock against slide.
Additionally, units with swing-out sidelites can be equipped with Adams Rite Series 8600 concealed
vertical rod exit devices on the doors to lock against swing. Surface applied units and units with fixed
sidelites can be equipped with Jackson Model 1085P paddle-type concealed vertical rod exit devices
on the doors to lock against swing, if allowed by local code authorities).
F. F
INISH
: All exposed surfaces shall be 204-R1 clear anodized or 313-R1 two-step, hard coat dark
bronze anodized for Class 1 architectural finish. Other painted or anodized colors as specified.
G. S
AFETY
A
ND
A
CTIVATING
D
EVICES
: Unit shall have two infrared safety beams installed at 24 and 48
from the finished floor. On single slide units, beams will be installed in the vertical stile of the sidelite
facing the door opening [in the filler tube on surface mount units] and the lock side jamb. On biparting
units, beams will be installed in the vertical stiles of the sidelites [in the filler tubes on surface mount
units]. The beams will not be active when the doors are fully closed.
Motion sensors shall be installed on both sides of the unit to detect traffic approaching the door from
either direction. For units intended for one-way traffic only, the motion sensor on the side not intended
for use shall not be active when the doors are fully closed.



M
AUTOMATED ENTRANCE SYSTEMS
K
KM
SYSTEMS, INC.
4910 STARCREST DRIVE (28110)
P.O. BOX 3099
MONROE, NC 28111-3099 PH. 1-800-438-1937




3/03


AUTOMATIC SLIDING DOORS

ARCHITECTURAL SPECIFICATIONS


SERIES 1100 ULTRA-GLIDE
SLIDING ENTRANCES

11-3.01


2.03 R
EQUIREMENTS
F
OR
W
ORK
S
PECIFIED
I
N
O
THER
S
ECTIONS

ELECTRICAL: The General Contractor or Electrical Contractor shall furnish and install all wiring to
operator. Provide 120VAC, 60 Hz, 1 phase, 15 amp service to each operator header on a separate,
dedicated circuit routed into the header.

PART 3: EXECUTION

3.01 I
NSPECTION