RS Chimney Fan for Gas & Oil Applications


« back to results for ""
Below is a cache of http://us.exhausto.com/files/pdf/InstallationManuals/3000270.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
RS Chimney Fan for Gas & Oil Applications
3000270 01.08
Installation & Operating Manual
USA
CAN
RS Chimney Fan
for Gas & Oil Applications

CM
INTERTEK
LISTED
C
US
EXHAUSTO Inc.
1200 Northmeadow Pkwy.
Suite 180
Roswell, GA 30076
P: 770.587.3238
F: 770.587.4731
T: 800.255.2923
info@exhausto.com
us.exhausto.com
Job Name:
Installer:
Installation Date:
Product Information
Mechanical Installation
Electrical Installation
Start Up and Configuration
Maintenance and Troubleshooting
........................ Chapter 1 + 2
......................... Chapter 3
............................. Chapter 4
.................. Chapter 5
...... Chapter 6 2
3000270 01.08
Symbol Legend:
The following terms are used throughout this manual to bring attention
to the presence of potential hazards or to important information
concerning the product.
Danger: Indicates an imminent hazardous situation
which, if not avoided, will result in death, serious injury or
substantial property damage.
1. Use this unit in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed on the front of the manual.
2. Before servicing or cleaning the unit, switch off at service panel
and lock service panel to prevent power from being switched on
accidentally.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with applicable codes and standards.
4. Follow the appliance manufacturers guidelines and safety
standards such as those published by the National Fire Protection
Associations (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the
local code authorities.
5. This unit must be grounded.
Caution: Indicates an imminent hazardous situation
which, if not avoided, may result in personal injury or
property damage.
How to use this manual
This installation manual does not contain any system design
documentation. System design documentation is available from any
authorized EXHAUSTO representative.
Accessories and controls are not covered by this manual. Please refer
to these components individual manuals.
1. Product Information


1.1 Function ...............................................................................................3


1.2 Shipping ...............................................................................................3


1.3 Warranty ...............................................................................................3
2. Specifications


2.1 Dimensions and Capacities ..................................................................4


2.2 Planning Ahead ....................................................................................5
3. Mechanical Installation


3.1 Transport Safety Device .......................................................................6


3.2 Single Fan on Steel Chimney ...............................................................6


3.3 Single Fan on Brick Chimney ...............................................................7


3.4 Multiple Fans on Steel Chimney ...........................................................8


3.5 Multiple Fans on Brick Chimney - Oversized Flue ...............................8


3.6 Installation for High Temperatures ........................................................8


3.7 Wall Mounting of Chimney Fan .............................................................9


3.8 Installation of Proven Draft Switch (PDSS) ..........................................9
4. Electrical Installation


4.1 General ..............................................................................................10


4.2 Wiring Diagram for Single Fan with FSC ...........................................10


4.3 Wiring Diagram for Two Fans with FSC ............................................. 11


4.4 Wiring Diagram for Single Fan with EBC10 ....................................... 11

5. Start-Up and Configuration


5.1 System Testing ...................................................................................12


5.2 Adjusting the Chimney Fan Speed .....................................................12


5.3 Adjusting the Proven Draft Switch Setting .........................................12
6. Maintenance & Troubleshooting


6.1 Prior to Cleaning ................................................................................13


6.2 Care and Cleaning .............................................................................13


6.3 Chimney Cleaning Intervals ..............................................................13


6.4 Troubleshooting .................................................................................14




!
!
TO REDUCE THE RISK OF FIRE, ELEC-
TRICAL SHOCK OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING: 3
3000270 01.08
Use
Code Compliance
Listing


1. Product Information
1.1 Function


EXHAUSTO model RS Chimney Fan is a chimney top mounted ventilator that is designed to provide large flue gas


volume capacities. It is designed and intended for use with residential gas or oil fired central space heating sys-


tems, for volume water heating or for combination space heating/volume water heating. It is also suitable for



use with gas-fired fireplaces, stoves, BBQs or residential pizza ovens.


This product is developed to prevent draft problems from occurring by creating a mechanical draft in venting



systems and thereby also increasing the capacity and efficiency of a venting system.


The use of the EXHAUSTO RS Chimney Fan is not restricted to any type of chimney, because the fan creates a


negative pressure (below atmospheric) in the chimney or vent.







Installations must conform to requirements of the authority having jurisdiction. Where required by the authority


having jurisdiction, the installation must also conform to the Standard for Draft Equipment and The National



Fuel Gas Code, ANSI Z223.1/NFPA 54.


All electrical wiring must be in accordance with the requirements of authority having jurisdiction or, in the absence of


such requirements, with the National Electrical Code, NFPA70.


EXHAUSTO Model RS is tested and listed to UL Standard 378, Standard for Draft Equipment. The fan is manufac-


tured at an ISO9001 certified plant and bears the European CE compliance label.


The chimney fan must be interlocked with the connected appliance(s) to insure proper combustions and to avoid


flue gas spillage.
1.2 Shipping


The packing list (attached to one of the packages) clearly lists all items in the shipment and each package has a


label showing the contents. Check the list against all materials on the job site for completeness.

1.3 Warranty


Complete warranty conditions are available from EXHAUSTO, Inc. 4
3000270 01.08
2. Specifications
2.1 Dimensions & Capacities
Capacity
Sound Data
1 Junction Box
2
Conduit/cord
3
Motor
4
Motor Housing
5
Cooling Plates
6
Bird Screen
7 Base Plate
8
Locking Nut
9
Inlet
10 Axial Vane
11 Hinges
12 Capacitor
(inside junction box)
Model
Lw dB (measured in accordance with ISO 3744)
Lp
dB(A)
125Hz 250Hz
500Hz 1000Hz 2000Hz 4000Hz 8000Hz
RS 009
54
50
47
43
38
31
25
21
RS 012
64
60
55
52
48
42
34
30
RS 014
75
69
65
62
57
51
44
41
RS 016
81
76
72
69
64
58
52
47
Model
RS 009
RS 012
RS 014
RS 016
Discharge
Horizontal
Fan Type
Axial Vane
Motor Type
Totally enclosed, Variable speed, Class H
Voltage
V AC
1x120
RPM
1600
CFM
0.0 Ps
450
950
1400
1950
Amperage
Amps
0.5
1.2
1.4
3.9
Motor Output
HP
1/30
1/10
1/7
1/3
kW
0.025
0.08
0.1
0.25
Weight
lbs
29
37
47
61
kg
13
17
21
28
Dimensions
A
in
10.0
11.0
13.2
16.0
mm
250
275
330
450
B x B
in
12.0
14.6
16.8
19.2
mm
300
365
420
480
C
in
11.4
14.0
15.8
18.0
mm
285
350
395
450
D
in
3.0
3.4
4.0
4.0
mm
75
85
100
100
E
in
8.0
11.0
12.0
14.0
mm
203
275
300
350
Temperature
Rating
Interm.
575癋/300癈
Cont.
482癋/250癈 5
3000270 01.08
2.2 Planning Ahead
1. Observe proper combustion air requirements.
2. Provide a firm support system for the chimney fan.
3. Determine the type of system involved.
4. Observe proper safety measures are taken to assure safe use of the wood burning appliances


Combustion Air Requirements: Provisions for combustion air must be in accordance with applicable local codes.


If the heating system is installed in an unconfied space, adequate air vill be available via normal infiltration.


If the heating system in installed in a confined space, (a space with a volume less than 50 cubic feet per



1,000 Btu/hr of inpu