‡ SIGNET 8900 Multi-Parameter Controller

.......................................................................................................... 4
4.
Specifications .......................................................................................................................................... 5
5.
Installation and Basic Functionality ...................................................................................................... 7
5.1
Unpacking ....................................................................................................................................................................... 7
5.2
Tools and Equipment Required: ................................................................................................................................... 7
5.3
Plug-in Modules ............................................................................................................................................................. 7
5.3.1
I/O Module ....................................................................................................................................................................... 8
5.3.2
Power Module .................................................................................................................................................................. 8
5.3.3
Output Module ................................................................................................................................................................. 9
5.3.4
Relay Module ................................................................................................................................................................... 9
5.3.5
External Relay Module ................................................................................................................................................... 10
5.4
Mounting the Base Unit ............................................................................................................................................... 11
5.4.1
Panel Mounting .............................................................................................................................................................. 11
5.4.2
Mounting Accessories .................................................................................................................................................... 12
6.
Wiring ..................................................................................................................................................... 13
6.1
I/O Module (3-8900.401-X) ........................................................................................................................................... 13
6.1.1
What is S
3
L? ............................................................................................................................................................... 13
6.1.2
Wiring Topologies ........................................................................................................................................................... 13
6.1.2.1 Point-to-point .................................................................................................................................................................. 13
6.1.2.2 Daisy-chain .................................................................................................................................................................... 13
6.1.2.3 Multi-drop ....................................................................................................................................................................... 14
6.1.2.4 Combinations ................................................................................................................................................................. 14
6.1.2.5 Accessory Junction Boxes ............................................................................................................................................. 14
6.1.3
Maximum Cable Lengths ............................................................................................................................................... 14
6.1.3.1 Signal Type: Frequency ................................................................................................................................................. 14
6.1.3.2 Signal Type: S
3
L ............................................................................................................................................................. 15
6.1.4
I/O Module (3-8900.401-X) Wiring Diagrams ................................................................................................................. 16
6.2
Power Module (3-8900.402-X) ..................................................................................................................................... 19
6.3
Output Module (3-8900.405-X) .................................................................................................................................... 19
6.4
RS232 Communication Module (3-8900.404-1) ......................................................................................................... 19
6.5
Relay
Module (3-8900.403-X) ....................................................................................................................................... 20
6.6
External Relay Module ................................................................................................................................................. 20
7.
Operational Overview ........................................................................................................................... 21
7.1
Keypad Functions ........................................................................................................................................................ 21
7.2
General Operation Flowchart ...................................................................................................................................... 21
7.3
View Mode .................................................................................................................................................................... 22
7.3.1
Channel Types ............................................................................................................................................................... 22
7.3.2
Measurement Display Screens ...................................................................................................................................... 22
7.3.3
Derived Functions .......................................................................................................................................................... 23
7.3.4
Analog Output Values .................................................................................................................................................... 23
7.3.5
Relay Status Indicators .................................................................................................................................................. 23
7.3.6
Memo ............................................................................................................................................................................. 23
7.3.7
System Configuration ..................................................................................................................................................... 24
7.3.8
Menu Directory ............................................................................................................................................................... 24 2
8900 Multi-Parameter Controller
SIGNET
Important Safety Information Read and understand instruction manual before using this product. This unit is designed to be connected to equipment which can be hazardous to persons and property if used incorrectly.
Read and understand all associated equipment manuals and safety warnings before using with this product. Do not remove rear panel slot shields if the modules are not installed. Remove power to unit before wiring input and output connections. Wiring connections to this product should only be performed by qualified personnel. Do not exceed published specifications in the use of this product. In case of communication error or loss of source signal:
Relays will be deactivated.
Current outputs will go to 22.1 mA.
Voltage outputs will go to 0 V.
3-8900.620
100 - 240VAC
50-60Hz, 24VA MAX
~
11 - 24 VDC
0.7 A MAX.
N
L
+
-
Power Connection
DO NOT attempt to connect both
AC and DC at the same time
C
NO
NC
NO
NC
C
Solid State Relays
Rating:
50 mA 30V
Mechanical Relays
Rating:
5A 250 VAC
5A 30 VDC
~
+
-
+
-
~
CAUTION
8.
Menus ..................................................................................................................................................... 25
8.1
General Guideline ........................................................................................................................................................ 25
8.1.1
Pre-configuration Guidelines .......................................................................................................................................... 26
8.1.2
Making Measurements after Pre-configuration .............................................................................................................. 26
8.2
System Setup ............................................................................................................................................................... 27
8.3
Channel Settings .......................................................................................................................................................... 28
8.3.1
Flow ............................................................................