Impulse 100P om1
o alert the user of the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the product.
C
CA
AU
UT
TIIO
ON
N:: Risk of electrical shock DO NOT OPEN!
C
CA
AU
UT
TIIO
ON
N:: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside.
Refer servicing to qualified service personnel.
W
WA
AR
RN
NIIN
NG
G:: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture.
Before using this appliance, read the operating guide for further warnings.
Este s韒bolo tiene el prop髎ito, de alertar al usuario de la presencia de (voltaje) peligroso sin
aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para
constituir riesgo de descarga el閏trica.
Este s韒bolo tiene el prop髎ito de alertar al usario de la presencia de instruccones importantes sobre la
operaci髇 y mantenimiento en la informaci髇 que viene con el producto.
P
PR
RE
EC
CA
AU
UC
CIIO
ON
N:: Riesgo de descarga el閏trica O ABRIR!
P
PR
RE
EC
CA
AU
UC
CIIO
ON
N:: Para disminu韗 el riesgo de descarga el閏trica, no abra la cubierta. No hay piezas 鷗iles
dentro. Deje todo mantenimiento en manos del personal t閏nico cualificado.
A
AD
DV
VE
ER
RT
TE
EN
NC
CIIA
A:: Para evitar descargas el閏tricas o peligro de incendio, no deje expuesto a la lluvia o
humedad este aparato Antes de usar este aparato, Iea m醩 advertencias en la gu韆 de operaci髇.
Ce symbole est utilis dans ce manuel pour indiquer lutilisateur la pr閟ence dune tension dangereuse
pouvant 阾re damplitude suffisante pour constituer un risque de choc 閘ectrique.
Ce symbole est utilis dans ce manuel pour indiquer lutilisateur quil ou quelle trouvera dimportantes
instructions concernant lutilisation et lentretien de lappareil dans le paragraphe signal.
A
AT
TT
TE
EN
NT
TIIO
ON
N:: Risques de choc 閘ectrique NE PAS OUVRIR!
A
AT
TT
TE
EN
NT
TIIO
ON
N:: Afin de r閐uire le risque de choc 閘ectrique, ne pas enlever le couvercle. Il ne se trouve
lint閞ieur aucune pi鑓e pouvant 阾re repar閑 par lutilisateur. Confiez Ientretien et la r閜aration de
lappareil un r閜arateur Peavey agr殚.
A
AV
VE
ER
RT
TIIS
SS
SE
EM
ME
EN
NT
T: Afin de pr関enir les risques de d閏harge 閘ectrique ou de feu, nexposez pas cet
appareil la pluie ou lhumidit. Avant dutiliser cet appareil, lisez attentivement les avertissements
suppl閙entaires de ce manuel.
Dieses Symbol soll den Anwender vor unisolierten gef鋒rlichen Spannungen innerhalb des Geh鋟ses
warnen, die von Ausreichender St鋜ke sind, um einen elektrischen Schlag verursachen zu k鰊nen.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam
machen, die Handhabung und Wartung des Produkts betreffen.
V
VO
OR
RS
SIIC
CH
HT
T:: Risiko Elektrischer Schlag! Nicht 鰂fnen!
V
VO
OR
RS
SIIC
CH
HT
T:: Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es
befinden sich keine Teile darin, die vom Anwender repariert werden k鰊nten. Reparaturen nur von
qualifiziertem Fachpersonal durchf黨ren lassen.
A
AC
CH
HT
TU
UN
NG
G:: Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Ger鋞 nicht dem
Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
3
I
IM
MP
PO
OR
RT
TA
AN
NT
T S
SA
AF
FE
ET
TY
Y IIN
NS
ST
TR
RU
UC
CT
TIIO
ON
NS
S
W
WA
AR
RN
NIIN
NG
G:: When using electrical products, basic cautions should always be followed, including the following:
1.
Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
Do not use this apparatus near water.
6.
Clean only with a dry cloth.
7.
Do not block any of the ventilation openings. Install in accordance with manufacturers instructions.
8.
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including
amplifiers) that produce heat.
9.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third
prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10.
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the
point they exit from the apparatus.
11.
Only use attachments/accessories provided by the manufacturer.
12.
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When
a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13.
Unplug this apparatus during lightning storms or when unused for long periods of time.
14.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in
any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15.
Never break off the ground pin. Write for our free booklet Shock Hazard and Grounding. Connect only to a power
supply of the type marked on the unit adjacent to the power supply cord.
16.
If this product is to be mounted in an equipment rack, rear support should be provided.
17.
Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in
susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently
intense noise for a sufficient time. The U.S. Governments Occupational and Health Administration (OSHA) has
specified the following permissible noise level exposures:
Sound Duration Per Day In Hours
Sound Level dBA, Slow Response
8
90
6
92
4
95
3
97
2
100
1 1/2
102
1
105
1/2
110
1/4 or less
115
According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors to the
ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if exposure
is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is
recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be
protected by hearing protectors while this unit is in operation.
S
SA
AV
VE
E T
TH
HE
ES
SE
E IIN
NS
ST
TR
RU
UC
CT
TIIO
ON
NS
S!!
4
I
In
nttrro
od
du
uccttiio
on
n
Thank you for purchasing the powered version of the Impulse
100. The 100P features a biamped power
section that provides 200 Watts peak dynamic power for the woofer, and 70 Watts peak dynamic power
for the compression driver tweeter, both with Peaveys DDT
compression. Offering a 10" heavy-duty, long-
throw woofer and the 14XT
compression driver, the 100P provides line-level balanced inputs with volume
control and loop-thru jacks.
I
Im
mp
pu
ulls
se
e 110
00
0P
P
Bi-amplified powered system with 200 W total power
Both power amps have DDT compression
10" premium heavy-duty, long throw woofer
14XT 1.4" titanium compression driver
Peak SPL in excess of 120 dB with music!
1/4" TRS and M/F XLR line-level balanced inputs
Molded-in horn has exceptionally smooth response and pattern control
Loop Out/In jacks allow link-up of multiple units
Top handgrip
E
EN
NG
GL
LIIS
SH
H
5
P
PA
AN
NE
EL
L D
DE
ES
SC
CR
RIIP
PT
TIIO
ON
N
(
(11)) FFU
US
SE
E
The unit is AC power line fuse protected from
overloads and fault conditions with an ABC-type
fast-blow 5 Amp fuse. In the rare event of a fuse
blowing: first make sure the unit is unplugged
and the power switch is in the OFF position, then
replace the blown fuse ONLY with a fast-blow 5
Amp 250V AC rated fuse. Be sure to fully seat and
close the replacement fuse and fuse holder cap.
Reconnect the unit to the AC power line, and with
the volume turned completely down (fully CCW),
turn on the power switch. If the unit blows the
fresh fuse, DO NOT continue to replace fuses, but
have the unit checked by a qualified service
technician.
(
(2
2)) IIE
EC
C P
PO
OW
WE
ER
R C
CO
OR
RD
D C
CO
ON
NN
NE
EC
CT
TIIO
ON
N
The removable AC power cord plugs into this
socket to supply AC line voltage to the power
switch.
(
(3
3)) O
ON
N--O
OFFFF S
SW
WIIT
TC
CH
H
This switch supplies AC power to the system
electronics when switched to the ON position.
(
(4
4)) P
PO
OW
WE
ER
R LLE
ED
D
Illuminates when the preamp electronics receive
power, and should illuminate when the On-Off
Switch is in the ON position and the AC power
cord is connected and plugged in to the wall
outlet.
(
(5
5)) P
PR
RIIM
MA
AR
RY
Y IIN
NP
PU
UT
TS
S//O
OU
UT
TP
PU
UT
TS
S
The input and output jacks are in parallel to allow
the audio input signal to be daisy-chained to
other devices. The output level is the same as
the input level and there is no isolation
between the various jacks. The input is of the
medium impedance balanced type. Jack (5a) is a
combo female XLR and 1/4" RTS connector, and
jack (5b) is a male XLR.
(
(6
6)) V
VO
OLLU
UM
ME
E
Controls the gain (level) of the Impulse
100P
system. When used with the Primary Input In/Out
jacks (5), it is used to directly set the system
output level
1
3
2
4
6
5
7
R
RE
EA
AR
R
F
FR
RO
ON
NT
T
6
(
(7
7)) L
LO
OO
OP
P--T
TH
HR
RU
U JJA
AC
CK
KS
S
Loop Out takes the signal after the balanced i