ROME TELEPHONE POWER CABLE, 600 VOLTS

SPEC 7060
January 1, 2002 ROME TELEPHONE POWER CABLE, 600 VOLTS
HYPALON® Insulation, Cotton Braid, Gray Saturant and Finish Type RHH or RHW, VW-1, Oil Res ll, Sun Res For CT Use APPLICATION: General purpose wiring in telephone central office power plants in raceway or on racks or trays where the gray finish harmonizes with the color of other telephone equipment. Cables are rated 90oC in dry locations, 75oC in wet locations at a maximum circuit voltage of 600 volts. STANDARDS: 1. Listed by UL as Type RHH or RHW per Standard 44. 2. Cables pass UL and IEEE-383 ribbon burner flame test and are UL listed Sunlight Resistant For CT Use (1/0 AWG and larger). 3. All sizes UL listed as VW-1. 4. Insulation UL listed as Oil Resistant ll. 5. Listed by CSA as 105oC AWM, 600V, FT1 and FT4 (4 AWG and larger). 6. Insulation and treated cotton braid have LOI of 28% minimum per ASTM D-2863. 7. Cable complies with Bellcore Spec GR-347-CORE. CONSTRUCTION: Annealed tinned copper conductor, separator, black HYPALON® (chlorosulfonated polyethylene) insulation, polyester tape, cotton braid, gray saturant and finish, surface printed. Cotton Braid with Gray Saturant and Finish Hypalon Insulation Polyester Tape(3) Tinned Copper Conductor Insulation Thickness Size AWG or kcmil No. of Strands Mils mm Nominal Diameter Inches mm Approx. Net Weight lb/1000 Ft. kg/km Ampacity* RHH 90 C Dry RHW 75 C Wet/Dry 14 12 10 8 6 4 2 1/0 2/0 4/0 350 500 750 7 7 7 7 7 7 7 19 19 19 37 37 61 45 45 45 60 60 60 60 80 80 80 95 95 110 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.41 2.41 2.79 .21 .23 .26 .31 .35 .40 .46 .58 .62 .73 .93 1.05 1.26 5.3 5.8 6.6 7.9 8.9 10.2 11.7 14.7 15.8 18.5 23.6 26.7 32.0 29 40 56 87 124 180 265 425 520 785 1270 1770 2645 43.2 59.5 83.3 130 185 268 394 632 774 1168 1890 2634 3936 25t 30t 40t 55 75 95 130 170 195 260 350 430 535 20t 25t 35t 50 65 85 115 150 175 230 310 380 475 *AMPACITY in accordance with NEC for not more than three conductors in raceway at the temperature indicated, 30oC ambient temperature.
t The over current protection shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG and 30 amperes for 10 AWG. 1. 2. 3. 4. Stocking colors are gray and green. Other colors available upon request. HYPALON® is a DuPont synthetic rubber. Size 6AWG and larger. This cable also referred to as CK-5482-H. NOTES: Information on this sheet subject to change without notice. SPEC 7060
1-1-02 Specification ROME TELEPHONE POWER CABLE, 600 VOLTS HYPALON® Insulation, Cotton Braid, Gray Saturant and Finish Type RHH or RHW, VW-1, Oil Res ll, Sun Res For CT Use
1. SCOPE 1.1 This specification describes a single conductor HYPALON® (chlorosulfonated polyethylene) insulated, cotton braided Telephone Power Cable suitable for general purpose wiring in telephone central office power plants. Cables may be installed in raceways, on racks or trays, or internally in equipment where the gray finish on the cable harmonizes with the color of other telephone equipment. Cables may also be supplied with a green finish to denote usage as a grounding conductor. Cables are listed by UL as Type RHH or RHW for general purpose building wire applications in circuits not exceeding 600 volts at a maximum continuous conductor temperature of 90oC in dry locations or 75oC in wet locations. Cables are listed by UL as VW-1 and Oil Resistant ll. Sizes 1/0 AWG and larger may be used in cable tray in accordance with Article 336 of the NEC. Cables are also listed by CSA as 105oC AWM and have FT-1 (all sizes) and FT4 (4 AWG and larger) flame ratings. 2. APPLICABLE STANDARDS 2.1 The following standards form a part of this specification to the extent specified herein: 2.1.1 Underwriters Laboratories Standard 44 for Rubber Insulated Wires and Cables. 2.1.2 Canadian Standards Association Standard C22.2 No. 210.2 for Appliance Wiring Material. 2.1.3 ASTM D-2863, latest issue - Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics. 2.1.4 Bellcore Spec GR-347-CORE Generic Requirements for Central Office Power Wire. 3. CONDUCTORS 3.1 Conductors shall be Class B stranded annealed tinned copper per UL Standard 44. 4. SEPARATOR 4.1 An opaque polyester separator tape shall be applied between the conductor and the insulation. 5. INSULATION 5.1 Each conductor shall be insulated with Rome-HYPALON, a black chlorosulfonated polyethylene rubber compound complying with the physical and electrical requirements of UL Standard 44 for Type RHH or RHW and 105oC AWM requirements of CSA C22.2 No. 210.2. The insulation shall have a minimum LOI of 28% when tested in accordance with ASTM D-2863. 5.2 The average thickness of insulation shall be as specified in UL Standard 44 for Type RHH or RHW. The minimum thickness at any point shall be not less than 90% of the specified average thickness. The insulation shall be applied tightly to the conductor and shall be free stripping. 6. TAPE 6.1 On sizes 6 AWG and larger, the insulation shall be covered with a wrapped opaque polyester tape. 7. BRAID 7.1 A close-weave cotton braid shall be applied over each cable. The braid shall comply with the requirements of UL Standard 44. 8. SATURANT / FINISH 8.1 The cotton braid shall be saturated with a heat, moisture and flame-retardant compound complying with requirements of UL Standard 44. Color of the saturant compound shall be gray. 8.2 The saturated cotton braid shall be coated with a lacquer paint to provide a gray or green color. 8.3 The saturated lacquered cotton braid forming the external finish shall present a uniform external appearance, shall be smooth, dry and free from irregularities and shall not flake-off. 8.4 The saturated, finished cotton braid shall have a minimum LOI of 28% when tested in accordance with ASTM D-2863. 9. SURFACE MARKING 9.1 An ink print legend shall be applied to each cable indicating manufacturer, size, voltage, UL and CSA designations. 10. TESTS 10.1 Completed cables shall be tested in accordance with the applicable requirements of UL Standard 44, CSA Standard C22.2 No. 210.2 and Bellcore Spec GR-347-CORE.