Model 60010-2 Series 255 SL

2 Series
255 SL
Model 60010-2 Series
REMOTE CONTROL
SEARCHLIGHT
FEATURES
Two High Output Sealed Beam Lamps
Sleek Design
Rugged Construction
Full 360° Rotation
Remote Control and 25 ft. Cable Included
Tough Polyurethane Finish
SPECIFICATIONS
Voltage:
12 Vdc, 24 Vdc
Amps:
8(12 V), 4(24 V)
Elevation Angle
(degrees):
Up: 30°, Down: 30°
Housing Material:
Thermoset Plastic
Candle Power:
200,000
Model
Bulb
Weight
Standard
Number
Voltage
Amps
Type
lb (kg)
Carton
60010-2012
12 Vdc
8
SPOT/SPOT
11 (5)
1
60010-2024
24 Vdc
4
SPOT/SPOT
11 (5)
1
APPLICATION
Ideal for larger boatslocate buoys, moorings, channel
markers, etc. Ideal for larger motorhomes and bus
conversionspinpoint road signs, campsites, or use as
backup light.
INSTALLATION INSTRUCTIONS
LIGHT MOUNTING
Select a location for the light which will allow clear beam
projection forward and as far aft as possible. Searchlight
base should be mounted on a level, flat surface. A
mounting block between the searchlight base and
mounting surface can be used. The block should be
contoured to fit the deck so the searchlight base is level.
See mounting template attached for plug and cable
required clearance.
1.
Mount light with front of base towards the direction of
most intended use (front of circular base is marked
"front") with gasket under light base.
2.
Feed wire through hole and secure light in place.
NOTE: cable connectors are provided for easy wiring
connections.
Mounting hardware is provided:
4
1/4-20 x 2" (6.5mm x 50mm) bolts
4
lockwashers
4
flatwashers OPTIONAL SECONDARY
CONTROL MOUNTING
If an additional control station is desired use control kit
numbers 43670-0004 (12 volt) or 18753-0335 (24 volt).
Mount secondary control in same manner as main
control. Mount station selector panel near the main
control (flybridge or lower).
1.
Cut a 2" x 1-3/8" (51mm x 35mm) opening for station
selector panel within a 1 foot radius of the control.
2.
Route secondary control cable from station selector
panel to secondary control location (cable acquired
separately - see cable listing).
3.
Insert
station selector panel thru mounting hole and
attach connectors to mating connectors from control
and search-light. The connector marked "flybridge"
to go to flybridge control and the connector marked
"lower" to lower control. The connector to the nearest
control can be plugged directly into the control. See
diagram.
4.
Use bedding compound or sealant to waterproof
station selector panel mounting.
5.
Secure panel with self-tapping screws provided.
CIRCUIT PROTECTION
Two (2) automotive blade type fuses are included in the
control. One (10 amp) protects the bulb circuit, the other
(3 amp) protects the motor circuit. In the event that it
should be necessary to replace a fuse simply pull off the
protective cover and slide the fuse out.
TROUBLESHOOTING
All lights are thoroughly inspected before shipping and are warranted to operate within specifications. If light does not operate
correctly, CHECK FUSES, AND WIRE HARNESS CONNECTIONS BEFORE PROCEEDING WITH THIS TROUBLESHOOTING.
PROBLEM
Control lever works in reverse in all directions.
Light moves in only three of the possible four directions.
Dim light (low voltage)
Bulb operates - no light movement
or
Light moves - bulb does not operate.
SOLUTION
See wiring instructions.
A. Check connectors.
B. Replace control.
C. If problem persists, return light & control for service.
A. Check voltage at power source.
B. Refer to cable listing for proper wire gage and length.
A. Check fuses on front of control.
B. Check bulb.
3 Amp
Fuse
10 Amp
Fuse
CONTROLS (INCLUDED)
43670-0003 12 V
60070-0000 24 V PARTS LIST
Part
Key
Description
Number
1
Upper Housing
60016-1000
2
Lower Housing
60017-1000
3
Base with Gasket
60088-1000
4
Lens with Gasket
60015-1000
5
Bulb (2 Req'd)
18753-0336
6
Bulb Housing
60018-1000
7
Cable Assembly
60063-1000
8
Motor Kit Vertical (Upper)
18753-0458
9
Motor Kit Horizontal (Lower)
18753-0350
10
Drive Arm/Gear
18753-0457
11
Bulb Clip Kit
18753-0459
12
Screws
18753-0471
BULB REPLACEMENT
1.
Disconnect wires, noting location on bulb.
2.
Loosen the screws on the bulb retaining clips.
3.
Remove bulb from bulb housing.
4.
Install new bulb making certain that the boss
on the bulb edge is in the H shaped locating
clip in the center of the bulb housing.
5.
Tighten screws on the bulb clips.
6.
Reconnect wires in previous positions.
WIRING DIAGRAM
RED
BLACK
ORANGE
BLACK
GRA
Y
BLACK
ORANGE
BLACK
GRA
Y
12 VOLT SPOT/SPOT 24 VOLT SPOT/SPOT
BULB REPLACEMENT REFERENCE
Model No.
Bulb
60010-0012
12V
18753-0336
60010-0024
24V
18753-0336
DUAL STATION KIT
Model
Kit
60010-0012
12V
43670-0004
60010-0024
24V
18753-0335
*NOTE: A 25' wiring cable is provided with each light.
Additional lengths may be ordered. Duel station kits
require additional cables (see wiring diagram). Order
cable length required from table below.
ACCESSORY CABLE LISTING
Part Number
Description
43990-0013
10' Cable Assembly
43990-0014
15' Cable Assembly
43990-0015
25' Cable Assembly
43990-0016
35' Cable Assembly
67294-0000
50' Bulk Cable
NOTE: Secure cable with nylon clips or equivalent.
Protect installation at points of stress, and leave
adequate slack where cable must be flexible. U.S.A.
Jabsco
1485 Dale Way, P.O. Box 2158
Costa Mesa, CA 92628-2158
Tel:
714.545.8251
Fax: 714.957.0609
UNITED KINGDOM
Jabsco
Bingley Road, Hoddesdon
Hertfordsire EN11 OBU
Tel:
+44 (0) 1992 450145
Fax: +44 (0) 1992 467132
CANADA
Fluid Products Canada
55 Royal Road
Guelph, Ontario N1H 1T1
Tel:
(519) 821.1900
Fax: (519) 821.2569
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
Tel:
045.475.8906
Fax: 045.475.8908
GERMANY
Jabsco GmbH
Oststrasse 28
22840 Norderstedt
Tel:
+49-40-53 43 73 -0
Fax: +49-40-53 53 73 -11
THE PRODUCTS DESCRIBED HEREIN ARE
SUBJECT TO THE JABSCO ONE YEAR LIMITED
WARRANTY, WHICH IS AVAILABLE FOR YOUR
INSPECTION UPON REQUEST.
© Copyright 2001, ITT Industries Printed in U.S.A.
All Rights Reserved
Form: 43000-0525
Rev. 1/2001
12 VOLT POWER
INPUT LEADS SUPPLIED
BY CUSTOMER (16 GA.)
12 VOLT POWER
INPUT LEADS SUPPLIED
BY CUSTOMER (16 GA.)
MAIN CONTROL
STATION SELECTOR
PANEL
SECONDARY
CONTROL
CABLE MUST
BE ACQUIRED
SEPARATELY
(SEE CABLE
LISTING)
SECONDARY CONTROL
KIT NO. 43670-0004 12V; 18753-0335 24V
WIRING DIAGRAM,
OPTIONAL SECONDARY REMOTE CONTROL
12 VOLT POWER
INPUT LEADS SUPPLIED
BY CUSTOMER (16 GA.)
WIRING DIAGRAM SINGLE CONTROL
25' CONTROL CABLE INCLUDED
FOR ADDITIONAL CABLES
SEE CABLE LISTING
CONTROL
5-3/8"
(136mm)
1/4"
(6mm)
6-1/8"
(156mm)
8-13/16"
(224mm)
10-1/2"
(267mm)
10-15/16"
(227mm)
5"
(127mm)
6-5/8"
(168mm)
30
°
(Bulb only)
30
°
(Bulb only)
STATION
SELECTOR
PANEL
DRAWING
1-1/2"
(38mm)
2-1/4"
(57mm)
REMOTE CONTROL
MOUNTING DIMENSIONS
1-1/2"
(38mm)
3-1/2"
(89mm)
2-5/8"
(67mm) 3-1/8"
(79mm)
3-3/4"
(95mm)
3-5/16"
(84mm)
DIMENSIONAL DRAWING
Inches (Millimeters) FRONT
1" (25mm) DIA
HOLE
FOR CABLE
MOUNTING HOLE
FOR 1/4" (6.5mm) BOL
T
(EQUALL
Y
SP
ACED-ON
5-3/4" (146mm) DIA
B.C.)
60010-Series
60080-Series
MOUNTING TEMPLA
TE
43000-0525 and 43000-0568 Rev
. 1/95