F-04 to 44 Forced Air Final
or=ccccff>
« back to results for ""
Below is a cache of http://www.chromalox.com/catalog/resources/dra.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive.
Yahoo! is not affiliated with the authors of this page or responsible for its content.
F-04 to 44 Forced Air Final
Comfort
F-30
7.5 to 30 kW
25,590 to 102,360 BTUH
208, 240, 480 and 600 Volts
Single and Three Phase
No Assembly Required
Built-in Controls
Description
The Chromalox DRA Dragon is a rugged
industrial grade, self contained, highly mobile,
electric blower heater. The DRA can be left
unattended without the threat of poisoning
from combustion by-products associated with
fuel fired heaters. The built in safety features
include an adjustable thermostat to control the
outlet air temperature, auto-reset cutouts for
the fan motor and heating elements. The
thermostat provides settings for full off, fan
only and temperature control in the heating
setting. Dragon heaters feature a large, easily
accessible control and wiring compartment
containing a magnetic contactor; additional
safety is provided by a 120 volt control voltage
transformer and motor starter on 480 and 600
volt units. The bright red polyester powder
coated heating cylinder is highly visible and
can be rotated to direct heat or fan driven air
movement where it is needed. For assured
safety, all standard units meet the require-
ments of UL (File No. E7061) and CSA (File
No. LR40859).
Construction
Heating Cylinder
A structural frame consisting of 2 spun steel
rings and 2 formed steel channels support a
20 gauge steel cylinder phosphate coated for
corrosion resistance, and finished in red
polyester powder coat paint. The heating
cylinder pivots vertically to direct air flow.
DRA
Portable Spot Industrial
Salamander Blower Heater
Leg Assembly
Each side consists of a one piece, 12 gauge,
formed steel member, which accepts a steel
tubular handle, held in place with a 1 1/2" long
x 1/4" bolt on each side. The handle can be
raised from the shipping position if desired.
The rubber, pneumatic wheels are 10"
diameter and 3 1/2 wide to provide ease of
transporting the heater on irregular and gravel
surfaces. The large wheels make it easy to roll
up stairways without damage to decorative
step surfaces.
Fan Assembly
The self-centering fan assembly consists of a
totally enclosed, permanently lubricated motor
and a dynamically balanced aluminum fan
blade for smooth, quiet operation.
Controls
A thermostat, with a temperature range of
40°F to 100°F is included, with a full off
position, a fan only position and an adjustable
range of temperature settings in the heating
mode position. Each unit includes a 3 pole
magnetic contactor and auto-reset thermal
cutout. 480 volt and 600 volt units also
include a motor relay and 120 volt control
voltage transformer for personnel safety.
Safety Guards
Front and rear grills are 10 gauge, finished in
black polyester powder coat and are designed
to meet OSHA safety requirements.
Heating Assembly
The patented metal sheath Fintube
®
heating
elements consist of steel fins furnace brazed
on industrial grade .475 diameter steel sheath
tubular heaters for maximum heat transfer.
The elements are held in place with steel
bulkhead fittings for durability. The elements
feature a high temperature finish for corrosive
protection.
Applications
For Best Results Use in Enclosed Area with
Ceiling Heights Below 15'
Any Commercial or Industrial Application
Needing Instant Fan Forced Heat
Building Construction
Curing Plaster and Concrete
Warming Workers
Thawing Frozen Pipes
Thawing Railroad Cars
Heating Large Tents
Non-Hazardous Areas
Dimensions (Inches)
(27-11/16)
(Handle Fully
Extend 34-1/4)
(18-1/2 O.D.)
(16-1/2 I.D.)
(23-7/16)
(20-9/16)
Comfort
FORCED AIR
F-31
DRA
Portable Spot Industrial
Salamander Blower
Heater
(contd.)
Cable packages include 25 feet Type SO
cable, with either 3-conductors or 4-conduc-
tors, depending on the heater requirements.
Each cable assembly includes the proper
cord (connector). Plugs are not included. All
models are factory wired for 3-phase, but
can be field wired for single phase, select plug
and cord accordingly.
SO = Hard Service Cord, 600V.
Length = 25 Feet
Cable Kits for Chromalox DRA Series Portable Blower Heaters
PLC-2514-4
15kW 600V 3PH
14/4 SO
15
90°C
3/4
S
295427
7
PLC-2512-4
7.5kW 240V 3PH
12/4 SO
20
90°C
1
S
295435
9
15kW 480V 3PH
20kW 600V 3PH
PLC-2510-3
15kW 600V 1PH
10/3 SO
30
90°C
1
S
295443
9
PLC-2510-4
7.5kW 208V 3PH
10/4 SO
25
90°C
1
S
295451
11
9.75kW 240V 3PH
20kW 480V 3PH
PLC-2508-3
7.5kW 208V 1PH
8/3 SO
40
90°C
1
S
295460
12
7.5kW 240V 1PH
15kW 480V 1PH
20kW 600V 1PH
PLC-2508-4
9.75kW 208V 3PH
8/4 SO
35
90°C
1
S
295478
15
30kW 600V 3PH
PLC-2506-3
9.75kW 208V 1PH
6/3 SO
55
90°C
1
S
295486
16
9.75kW 240V 1PH
20kW 480V 1PH
PLC-2506-4
15kW 240V 3PH
6/4 SO
45
90°C
1
S
295494
17
30kW 480V 3PH
PLC-2504-4
19.5kW 240V 3PH
4/4 SO
60
90°C
1 1/4
S
295515
25
Cord
Cable Specifications
Connector
Max.
Temp.
Wt.
Model No.
Used on Heater
Size/Type
Amp Ratings
NPT
Stock
PCN
(Lbs.)
Stock Status:
S = stock
AS = assembly stock
NS = non-stock
To OrderSpecify model, PCN, kW, volts, phase and quantity.
1. Includes motor amps
See back page for control, thermostat and fan options.
2. Temperature rise at 240V operation
All units are factory wired for 3 phase operation.
3. 208V amperage is 86% of 240V value
Models designated 1 and 3 phase can be field wired for single phase operation.
Specifications And Ordering Information
7.5
208
1 and 3
36.3/21.0
25,590
0.06
1070
23
DRA-07-83
NS
295523
65
7.5/5.6
240/208
1 and 3
31.5/18.3
3
25,590
0.06
1070
23
DRA-07-23
S
295531
65
9.75
208
1 and 3
47.1/27.3
33,267
0.06
1070
31
DRA-10-83
S
295540
65
10/7.5
240/208
1 and 3
40.8/23.7
3
33,267
0.06
1070
31
DRA-10-23
S
295558
65
15
208
3
41.8
51,180
0.06
1070
46
DRA-15-83
NS
295566
65
15/11.2
240/208
3
36.3
3
51,180
0.06
1070
46
DRA-15-23
S
295574
65
15
480
1 and 3
31.4/18.2
51,180
0.06
1070
46
DRA-15-43
S
295582
65
15
600
1 and 3
25.2/14.6
51,180
0.06
1070
46
DRA-15-93
NS
295596
65
19.5/15
240/208
3
47.1
3
66,534
0.06
1070
61
DRA-20-23
S
295603
75
20
480
1 and 3
42.0/24.4
68,240
0.06
1070
62
DRA-20-43
S
295611
75
20
600
1 and 3
33.5/19.4
68,240
0.06
1070
62
DRA-20-93
NS
295620
75
30
480
3
36.3
102,360
0.06
1070
92
DRA-30-43
S
295638
75
30
600
3
29.1
102,360
0.06
1070
92
DRA-30-93
NS
295646
75
Temp.
Wt.
kW
Volts
Phase
Amps
1
BTU/H
HP
CFM
Rise °F
2
Model
Stock
PCN
(Lbs.)
Comfort
F-32
LOCKING
PGL-15-20
3 Pole, 4 Wire
250
20
L15-20
C73.85
.385-.780
ST
338845
0.5
LOCKING
PGL-15-30
3 Pole, 4 Wire
250
30
L15-30
C73.86
.385-.780
ST
338853
0.5
LOCKING
PGL-16-30
3 Pole, 4 Wire
480
30
L16-30
C73.88
.595-1.150
ST
338861
0.5
LOCKING
PGL-17-30
3 Pole, 4 Wire
600
30
L17-30
C73.89
.595-1.150
ST
338870
0.5
LOCKING
PGL-3763C
2 Pole, 3 Wire
600
50
.750"-1.125"
ST
338917
0.5
LOCKING
PGL-3765C
3 Pole, 4 Wire
600
50
.750"-1.125"
ST
338925
0.5
NON
PGN-6-50
2 Pole, 3 Wire
250
50
6-50
C73.53 .625-1.187
ST
338888
0.5
LOCKING
NON
PGN-15-20
3 Pole, 4 Wire
250
20
15-20
C73.59
.390-.775
ST
338896
0.5
LOCKING
NON
PGN-15-50
3 Pole, 4 Wire
250
50
15-50
C73.61 .750-1.250
ST
338909
0.5
LOCKING
Plug Kits
Fits
Wt.
Plug Type
Catalog Number
Description
Volts
Amps
Configuration
NEMA#
ANSI#
Cable Dia.
Stock
PCN
(Lbs.)
G
W
X
Z
G
W
X
Z
G
X
G
Y
Z
X
G
Y
Z
X
G
Y
Z
X
G
Y
Z
Y
G
X
X
Y
Z
DRA
Portable Spot Industrial
Salamander Blower
Heater
(contd.)