FP90 Wood Fireplace

Y FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free
enjoyment. This product has been certi ed by the Environmental Protection Agency of the United
States. This means that it meets the strictest standards in providing you with the latest in clean
burning technology and ef ciency. Speci cations may vary widely. Consult with your FPI Dealer
for local considerations.
Keep those REGENCY FIRES burning. FPI FP90 Wood Fireplace
3
TABLE OF CONTENTS
SAFETY LABEL
Safety
Label For FP90 ..................................................4
INSTALLATION
Product Details ..............................................................5
EPA Certi ed ..........................................................5
Options ..................................................................5
Read Before You Install .................................................6
Dimensions And Speci cations .....................................6
Clearances And Height Requirements ..........................7
Installation Of Nailing Strips ..........................................8
Fireplace Enclosure Framing ........................................8
Framing Details .............................................................9
Location Of Fireplace ....................................................9
Hearth Extension ...........................................................9
How To Determine If Alternate Floor Protection
Materials Are Acceptable .......................................9
Chimney System Considerations ................................10
Chimney Height ...................................................10
Chase Enclosure .................................................10
Before You Start ........................................................10
Installation Components ......................................10
Installation Measurements/framing Details ................. 11
Assembly Steps ...........................................................12
Installing The Stand-offs ..............................................12
Set The Regency FP90 Into Position ..........................12
Installing The Chimney System ...................................12
Offset Chimney Installation ..................................13
Required Firestop, Radiation Shield, Or
Attic Insulation Shield (Table 1) ...................................14
Minimum Recommended Flue Height In Feet
(Table 2) ......................................................................14
Installing The Outside Air Kit .......................................14
Wiring The FP90 ..........................................................15
Installing The Blower Systems ....................................15
Internal
Blower with Thermo-Disc ........................15
Gravity Air Feed Kit Option ..........................................15
Finishing The Regency FP90 ......................................16
Completing The Facing ........................................16
Non-self Supporting, Thin Veneer Facades
Installation ............................................................16
Masonry Retainer Kit Option ................................17
Finishing Details ..................................................17
Completing The Mantle ...............................................18
Masonry Liner / Bricks .................................................18
Louvers ........................................................................18
Glass Installation .........................................................18
Secondary Air Tube Installation ..................................18
Ash Drawer Kit Option ................................................19
Safety Precautions ...............................................19
Ash Drawer Kit Installation ...................................19
Ash Drawer Operating Guideline .........................19
OPERATING INSTRUCTIONS
Operating Instructions .................................................20
Draft Control ........................................................20
First Fire ......................................................................20
Safety Guidelines ........................................................20
MAINTENANCE
Plated Finishes ............................................................21
Door Gasket ................................................................21
Door Hinges ...............................................................21
Glass Cleaning ............................................................21
Glass Removal /Replacement .....................................21
Chimney Cleaning .......................................................21
PARTS LIST
Parts List- Firebox & Body ...........................................22
Parts List- Baf es, Door, Options ................................23
WARRANTY
The Warranty: Lifetime ...............................................24 FPI FP90 Wood Fireplace
4
SAFETY LABEL
SAFETY LABEL FOR FP90
This is a copy of the label that accompanies each Regency Fireplace.
It is located inside the lower louver opening on the left side. We have
printed a copy of the contents here for your review.
SAFETY LABEL
NOTE: Regency units are constantly being improved. Check the label
on the unit and if there is a difference, the label on the unit is the correct
one. FPI FP90 Wood Fireplace
5
INST
ALLA
TION
INSTALLATION
EPA Certi ed


Emissions
:
3.72
g/hr


Ef
ciency
(EPA)
: 63%

BTU/HR
(EPA)
: 11,720
(Lo)
to
42,400
(Hi)


Flue Size

:
8" (203mm) Diameter


Log
Size

:
20"
(508mm)

Shipping
Weight
:
612
lbs
(278kg)




Stripped
Weight
: 570
lbs
(259kg)



Options
Ashdrawer R90/EX90
Fan R90/EX90
Surround Black EX90
Surround Polished Gold EX90
Surround Antique Nickel EX90
Louver Flush Black R90
Louver Flush Black/Gold R90
Louver Flush Black/Steel R90
Surround Accent Gold Excalibur EX90
Surround Accent Brush Nickel Excalibur EX90
Wood Screen R90/EX90
Finishing Trim R90
Masonry Retainer Kit R90
Gravity Vent Kit R90
Air Cool Pipe Adaptor R90/EX90
1" Unit Base Standoffs
PRODUCT DETAILS FPI FP90 Wood Fireplace
6
INST
ALLA
TION
INSTALLATION
8) NEVER use gasoline, gasoline-type lantern
fuel, kerosene, charcoal lighter uid, or any
liquid to start or freshen up a re in this
replace. Keep any ammable liquid a safe
distance from the replace.
9) Ashes should be placed in a metal
container with a tight- tting lid. The closed
container of ashes should be placed on a
non-combustible oor or on the ground,
well away from all combustible materials,
pending nal disposal. If the ashes are
disposed of by burial in soil or otherwise
locally dispersed, they should be retained
in the closed container until all cinders have
thoroughly cooled.
10) WARNING: Only operate replace with
doors fully open when optional re screen
is used.
11) NEVER leave children unattended when
there is a re burning in the replace.
12) Allow the replace to cool before servicing.
Always shut-off any electricity to the replace
while working on it. This will prevent any
possible electrical shock.
13) Regency is not responsible for any
smoking or related problems that
may result from the lack of adequate
combustion air. It is the responsibility
of the installer to ensure that adequate
combustion air has been provided for
the replace.
14) FPI Fireplace Products International Ltd.
does not warranty smoke-free operation
nor are we responsible for inadequate
system draft caused by mechanical systems,
general construction conditions, inadequate
chimney heights, adverse wind conditions
and/or unusual environmental factors or
conditions beyond our control.
READ BEFORE YOU INSTALL
THE REGENCY HIGH
EFFICIENCY EPA CERTIFIED
FIREPLACE
This installation manual will enable you to make
a safe, ef cient and dependable installation of
your replace and chimney system. Please
read and understand these instructions before
beginning your installation.
Do not alter or modify the replace or its
components under any circumstances. Any
modi cation or alteration of the replace system,
including but not limited to the replace, chimney
components and accessories, may void the
warranty, listing and approvals of this system
and could result in an unsafe and potentially
dangerous installation.

PLEASE RETAIN THIS MANUAL FOR
FUTURE REFERENCE.
IMPORTANT: Please read and follow these
rules for safety.

1) Before starting your replace installation,
read these installation instructions carefully
to be sure you understand them in their
entirety. Failure to follow them could cause
a replace malfunction resulting in serious
injury and/or property damage.
2) Always check with your local building
department, fire department and local
authorities prior to installation to determine
the need to obtain a permit.
3) This model replace must be installed with
one of the chimney systems listed in the
Chimney Section in this manual. These
systems are intended for use as a residential
type appliance. The chimney must always
vent to the outside of the building.
4) WARNING: THIS FIREPLACE HAS NOT
BEEN TESTED WITH AN UNVENTED
GAS LOG SET. TO REDUCE RISK OF
FIRE OR INJURY, DO NOT INSTALL AN
UNVENTED GAS LOG SET INTO THE
FIREPLACE.
5) To ensure a safe replace system and to
prevent the build-up of soot and creosote,
inspect and clean the repla