LIT-385RevA
IMMS-SI
®
Installation Instructions
Communications Site Interface
Earth Ground
Drain wires here
Diagnostic Connector
IMMS
Site
Interface
To SmartPort
REM
SI 3
CI 3
AC
SI 1
CI 1
SEN
Ground
CI 4
SI 4
Sensor 2
Sensor 3
Sensor
Common
T
o
Con
troll
e
r
Fr
om CCC
F
r
o
m
S
e
n
s
o
r
s
24 VAC
24 VAC
T
o
F
i
r
s
t
C
I
SEN
AC
Sensor 1
Fr
om
T
r
an
sf
orm
er
Telephone
CI 2
SI 2
POWER
Controller
Comm.
A
B
TABLE OF CONTENTS .............................................................................................................
Mount the Cabinet ..................................................................................................................................................................... 1
Connect AC power ..................................................................................................................................................................... 2
Connect Interface to Controller ..................................................................................................................................................3
Connect Interface to ICC ............................................................................................................................................................ 3
Connect Interface to Pro-C and SRC ...........................................................................................................................................4
IMMS-SI Communications Connections ......................................................................................................................................5
Hardwire connection (IMMS-SI-HW) ..........................................................................................................................................5
Telephone Modem connection (IMMS-SI-MOD) ...........................................................................................................................6
Wireless Connection .................................................................................................................................................................. 6
Earth Grounding ........................................................................................................................................................................ 7
Power and Test .......................................................................................................................................................................... 7
A & B Buttons ........................................................................................................................................................................... 8
To Address Controller Interfaces ................................................................................................................................................8
Site Interface Reset ............................................................................................................................................................8
Diagnostics ............................................................................................................................................................................... 9
Additional Connections .............................................................................................................................................................. 9
Connections to Other Interfaces ............................................................................................................................................... 10
Connection to optional Clik sensors ......................................................................................................................................... 10
Powered sensors ..................................................................................................................................................................... 11
Wireless Rain-Clik ................................................................................................................................................................ 11
Flow-Clik IMMS ....................................................................................................................................................................... 12
Connection to optional remote receiver (SRR or ICR) ................................................................................................................ 13
GCBL ...................................................................................................................................................................................... 13
5 conductor sprinkler wire ....................................................................................................................................................... 14
RJ-11 Telephone cable ............................................................................................................................................................. 14
Earth Ground
Drain wires here
Diagnostic Connector
IMMS
Site
Interface
To SmartPort
REM
SI 3
CI 3
AC
SI 1
CI 1
SEN
Ground
CI 4
SI 4
Sensor 2
Sensor 3
Sensor
Common
T
o
Contr
oller
Fr
om CCC
F
r
o
m
S
e
n
s
o
r
s
24 VAC
24 VAC
T
o
F
i
r
s
t
C
I
SEN
AC
Sensor 1
Fr
om
T
r
ansformer
Telephone
CI 2
SI 2
POWER
A
B
1
Choose a dry, flat location on a suitable indoor or outdoor wall,
which will not receive spray from sprinklers. Telephone modem Site
Interfaces (IMMS-SI-MOD) must be located within 6 ft. (2 m) of the
telephone jack. Drive self-tapping screws through recessed holes in
plastic cabinet back into solid surface. Ambient operating temperature
must not exceed 120°F (50°C).
MOUNT THE CABINET ............................................................................................................
A
B
2
1. Verify that AC power is switched OFF at the power source
before beginning.
2. Remove the junction box cover (two screws).
3. Use appropriate electrical conduit and fittings to route AC power
wire into the junction box. Run high voltage power wiring in separate
conduit from low voltage signal wiring.
4. Connect the power wires to the transformer wires with wire nuts
(see color code chart), and replace junction box cover.
5. Installer is responsible for local electrical codes and wiring.
Transformer
Hot
Neutral
Safety Ground (required)
North America (115VAC)
Black
White
Green
International (230VAC)
Brown
Blue
Green with yellow stripe
CONNECT AC POWER .............................................................................................................
Earth Ground
Drain wires here
Diagnostic Connector
IMMS
Site
Interface
To SmartPort
REM
SI 3
CI 3
AC
SI 1
CI 1
SEN
Ground
CI 4
SI 4
Sensor 2
Sensor 3
Sensor
Common
T
o
Contr
olle
r
Fr
om CCC
F
r
o
m
S
e
n
s
o
r
s
24 VAC
24 VAC
T
o
F
i
r
s
t
C
I
SEN
AC
Sensor 1
Fr
om
T
r
ansformer
Telephone
CI 2
SI 2
POWER
A
B
Earth Ground
Drain wires here
Diagnostic Connector
IMMS
Site
Interface
T
o SmartPort
REM
SI 3
CI 3
AC
SI 1
CI 1
SEN
Ground
CI 4
SI 4
Sensor 2
Sensor 3
Sensor
Common
T
o
Contr
oller
Fr
om CCC
F
r
o
m
S
e
n
s
o
r
s
24 VAC
24 VAC
T
o
F
i
r
s
t
C
I
SEN
AC
Sensor 1
Fr
om
T
r
ansformer
T
elephone
CI 2
SI 2
POWER
A
B
3
1. Use approximately 6 ft. (2 m) of 18 AWG (1 mm) 5-conductor
sprinkler wire to connect interface to the controller.
2. Strip wires approximately
3
16
" (4.5 mm) and attach to interface, by
color, at the To Controller section of the terminal strips.
3. Route wire (in separate conduit from AC power) to the controller.
With controller power OFF, strip wire ends approximately ¼" (6 mm)
and connect by color code to the ICC power module
terminals as shown.
CONNECT INTERFACE TO CONTROLLER ............................................................................
CONNECT INTERFACE TO ICC ...............................................................................................
Earth Ground
Drain wires here
Diagnostic Connector
IMMS
Site
Interface
To SmartPort
REM
SI 3
CI 3
AC
SI 1
CI 1
SEN
Ground
CI 4
SI 4
Sensor 2
Sensor 3
Sensor
Common
T
o
Contr
olle
r
Fr
om CCC
F
r
o
m
S
e
n
s
o
r
s
24 VAC
24 VAC
T
o
F
i
r
s
t
C
I
SEN
AC
Sensor 1
Fr
om
T
r
ansformer
Telephone
CI 2
SI 2
POWER
A
B
Earth Ground
D
rain wires here
Diagnostic Connector
IMMS
Site
Interface
T
o SmartPort
REM
SI 3
CI 3
A
C
SI 1
CI 1
SEN
Ground
CI 4
SI 4
Sensor 2
Sensor 3
Sensor
Common
T
o
Contr
oller
Fr
om CCC
F
r
o
m
S
e
n