LVD MEASUREMENT AND TEST REPORT
t=1>
Yahoo! is not affiliated with the authors of this page or responsible for its content.
LVD MEASUREMENT AND TEST REPORT
LVD MEASUREMENT AND TEST REPORT
For
Certificate
Holder:
EVERTOP HARDWARE INDUSTRIAL CO.,
LIMITED
Address:
Hardware Technology Zone, Yongkang,
Zhejiang, China
Manufacturer:
EVERTOP HARDWARE INDUSTRIAL CO.,
LIMITED
Address:
Hardware Technology Zone, Yongkang,
Zhejiang, China
Equipment
Model:
ETF001C
Equipment Type:
Fit Massage
Test Standards:
EN 60335-1: 2002
EN 60335-2-32: 2003
Test Engineer:
Peter Deng
Test Date:
August 28, 2007
Issuance Date:
September 5, 2007
Reviewed By:
Oliver Deng - Vice-General Manager
Prepared By:
West (Sichuan) Ceprei Electronic Compliance Co., Ltd.
Room 1-27-06 Greenwich Building, No.1 Wangjiang
Road, Chengdu, Sichuan, P.R.China
Note:
This report may not be duplicated without prior written consent of
West (Sichuan) Ceprei Electronic Compliance Co., Ltd.
EN 60335
Clause
Requirement - Test
Result - Remark
Verdict
Certificate No.: EU 02 031729 01 Test Report No.:
252335150
Page 2 of 22
Test item
Description :
Fit
Massage
Trademark :
EVERTOP
Model and/or type reference
:
ETF001C
Multi-models are difference figure
from model ETF001C only
ETF002C, ETF003C, ETF004C, ETF005C
Manufacturer :
EVERTOP HARDWARE INDUSTRIAL CO., LIMITED
Rating(s)
:
220~240V AC 50Hz, 200W
Marking Plate
Fit Massage
Model: ETF001C
Rated Voltage: 220~240V AC
Rated Frequency: 50Hz
Power: 200W
EVERTOP HARDWARE INDUSTRIAL CO., LIMITED
EN 60335
Clause
Requirement - Test
Result - Remark
Verdict
Certificate No.: EU 02 031729 01 Test Report No.:
252335150
Page 3 of 22
3
GENERAL REQUIREMENTS
P
Appliances shall cause no danger to persons or
surroundings in normal use.
Compliance is checked by
carrying out all the relevant
tests
P
4
GENERAL CONDITIONS FOR THE TESTS
P
4.6
Appliances for a.c. only are tested with a.c. at
rated frequency.
a.c. power supply, 50Hz
P
6
CLASSIFICATION
P
6.1
Stationary appliances shall be of Class I, Class II,
Class III.
Ordinary appliance, Class I
P
7
MARKING AND INSTRUCTIONS
P
7.1
Appliance shall be marked with:
-rated voltage(s) or rated voltage range(s), in volts. refer to the marking plate
P
-rated input, if greater than 25W, in watts or
kilowatts
refer to the marking plate
P
-makers or responsible vendors name,
trade-mark or identification mark
refer to the marking plate
P
-makers model or type reference
refer to the marking plate
P
7.7
Terminals intended exclusively for the neutral
conductor shall be indicated by the letter N,
earthing terminals shall be indicated by the symbol
P
7.13
Instruction sheets and other texts shall be written
in the official language(s) of the country in which
the appliance is to be sold
Refer to users manual
P
7.24
Marking shall be easily legible and durable
After rubbing the marking
with water and petroleum
spirit, the marking is still
easily legible
P
8
PROTECTION AGAINST ACCESS TO LIVE PARTS
P
EN 60335
Clause
Requirement - Test
Result - Remark
Verdict
Certificate No.: EU 02 031729 01 Test Report No.:
252335150
Page 4 of 22
8.1
Appliances should be so constructed and
enclosed that there is adequate protection against
accidental contact with live parts
Compliance is checked by
inspection
P
8.9
Appliances intended to be connected to the supply
by means of a plug shall be so designed that in
normal use there is no risk of electric shock from
charged capacitors when touching the pins of the
plug
One second after
disconnection, the voltage
between the pins of the plug
< 34V
P
9
STARTING OF MOTOR-OPERATED APPLIANCES
N
10
POWER INPUT AND CURRENT
N
11
HEATING
P
11.1
Appliances and their surroundings shall not attain
excessive temperatures in normal use.
Temperature rises not
exceeding specified values
P
11.8
Temperature rise of various parts shall not exceed
the value in table 3.
Temperatures were not
exceeded.
P
13
LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING
TEMPERATURE
P
13.1
The electrical insulation at operating temperature
shall be adequate and the leakage current in
normal use shall not be excessive
See 13.2 and 13.3
P
13.2
The leakage current is measured between any
pole of the supply and the accessible metal parts
for single-phase appliance.
leakage current<0.75mA
P
13.3
Electrical insulation:
1000V for basic insulation
2750V for supplementary insulation
3750V for reinforced insulation
The test voltages is applied
between live parts.
P
15
MOISTURE RESISTANCE
EUT is for in-home use
N
EN 60335
Clause
Requirement - Test
Result - Remark
Verdict
Certificate No.: EU 02 031729 01 Test Report No.:
252335150
Page 5 of 22
16
LEAKAGE CURRENT AND ELECTRIC STRENGTH
P
16.1
The insulation and electric strength of appliances
shall be adequate
Refer to 16.2, 16.3
P
16.2
The leakage current is measured between any
pole of the supply and the accessible metal parts
for single-phase appliance with the 1.06 times
rated voltage power supply.
leakage current<0.75mA
P
16.3
The insulation resistance should have the
adequate value with a d.c. voltage of 500V
P
-between live parts and the body for basic
insulation
> 2 M
P
-between live parts and the body for reinforced
insulation
> 7 M
P
17
OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED
CIRCUITS
P
17.1
Excessive temperature do not occur in the
transformer or in the associated circuits when
there is short circuits in normal use
P
18
ENDURANCE
EUT is short-time operation
appliance
N
19
ABNORMAL OPERATION
Its impossible for EUT has a
abnormal or careless
operation
N
20
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ............... :
Apparatus with a mass more
than 7kg.
P
Apparatus intended to be fastened in place
suitable instructions
Not a apparatus intended to
be fastened in place.
N
20.1
Test on a plane, inclined at 10
o
to the horizontal
The apparatus is of a stable
mechanical construction and
did not overbalance when
placed on a plane which
inclined at an angle at 10
degrees.
P
100 N force applied vertically downwards
The apparatus did not tipped
over.
P
EN 60335
Clause
Requirement - Test
Result - Remark
Verdict
Certificate No.: EU 02 031729 01 Test Report No.:
252335150
Page 6 of 22
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
P
20.2
Edges or corners not hazardous
Edges and corners of the
enclosure are rounded.
P
21
MECHANICAL STRENGTH
N
22
CONSTRUCTIONS
P
22.1
Appliance shall be of Class I, Class II, Class III
Class I
P
22.2
Appliance shall have degree against moisture
For in-home use
N
23
INTERNAL WIRING
P
23.1
Wire way shall be smooth and free from sharp
edges
P
23.2
Internal wiring and electrical connections between
different parts of the appliance shall be adequately
protected or enclosed
P
24
COMPONENTS
P
24.3
Inductors and windings
Test with appliance
P
24.3.1
Transformers and inductors marked with
manufacturer's name and type ............................ :
The transformer is marked
the manufacturer and type.
P
Transformers and inductors separately approved : The transformer has been
tested within this report.
N
24.3.2
General
See 24.3.3, 24.3.4 and
24.3.5.
P
24.3.3
Constructional requirements
See below.
P
24.3.3.1
Clearances and creepage distances comply with
clause 29
See appended table 29.3 and
29.4.
P
24.3.3.2
Transformers meet the constructional
requirements
Compliance.
P
24.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
Min 2 layers of insulation
tapes between the
transformer primary and
secondary winding .
P
Coil formers and partition walls > 0,4 mm
P
24.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
24.3.4.2 are met
Class II construction
N
EN 60335
Clause
Requirement - Test
Result - Remark
Verdict
Certificate No.: EU 02 031729 01 Test Report No.:
252335150
Page 7 of 22
24.3.4.3 Separating transformers with at least basic
insulation
No separating transformer.
N
24.3.5.1
Class II transformers have adequate insulat