PORTABLE MODULAR DC HIPOTS

les. Each module is rated for 5 mA and is air insulated. Cooling
AN (AirNatural, Convection). Both models offer reversible polarity.
Each model consists of a base with casters, corona rings, a control cabinet, a regu-
lator cabinet, and the required number of modules to reach the desired voltage.
FEATURES
1. Control Power Switch
2. Main Power Indicator
3. Security Circuit Indicator Lamp
4. High Voltage On Pushbutton
5. High Voltage Off Pushbutton
6. Raise Output Voltage Pushbutton
7. Regulator Off Zero Indicator
8. Lower Output Voltage Pushbutton
9. Speed Adjust
10. Overload Reset
11. Overload Adjust (10110%)
12. Current Measurement Modes
13. Current Meter Range Selector
14. Output Current Meter (mA DC)
15. Negative Polarity Indicator
16. Positive Polarity Indicator
17. Number of Modules Stacked
18. Output Voltage Meter (kV DC)
19. Emergency Off

Easily stackable modules utilizing unique stacker plate design

No cumbersome interconnecting wires between modules

Modular construction, lightweight, rugged, and portable

Expandable from 60 kV DC to 360 kV DC or 100 kV DC to 600 kV DC

Reversible polarity

Zero-start interlock

External interlock provision

Motorized control of output voltage

Standard digital metering

Standard guard circuit to eliminate stray leakage current from specimen
under test

Ripple <0.2% per mA

Grounding stick

Interconnecting cables
Model 4180-5ST-60
CONTROLS AND INDICATORS
Hipot testing of:

Generators

Motors

Electrical Switchgear

Cables

Other Electrical Apparatus
APPLICATION * Based on our commitment to continual research and development, PHENIX Technologies reserves the right to update product specifications without notice.
** 30 Minutes ON / 60 Minutes OFF duty cycle applies for capacitive loads. 5 mA resistive load current duty cycle is 5 Minutes ON / 15 Minutes OFF.
MODEL NUMBER:
460-5ST-60
4120-5ST-60
4180-5ST-60
4240-5ST-60
4300-5ST-60
4360-5ST-60
INPUT: Voltage:
208-240 VAC
Current:
2.5 AAC
5 AAC
7.5 AAC
10 AAC
12.5 AAC
15 AAC
OUTPUT: Power:

Duty Cycle:

Voltage:

Current:

Polarity:

Ripple:
300 W
600 W
900 W
1200 W
1500 W
1800 W
30 Minutes ON / 60 Minutes OFF **
60 kV DC
120 kV DC
180 kV DC
240 kV DC
300 kV DC
360 kV DC
5 mA
POS / NEG
<0.2% per mA
METERING ACCURACY:
+1% F.S.
VOLTMETER RANGE:
0-60 kV DC
0-120 kV DC
0-180 kV DC
0-240 kV DC
0-300 kV DC
0-360 kV DC
AMMETER RANGE:
0 - 200 / 2000 / 10,000

DIMENSIONS/WEIGHT:
WIDTH
DEPTH
HEIGHT
WEIGHT

CONTROLS:
20/508 mm
14.5/370 mm
11/280 mm
42 lbs/19 kg
SINGLE HV MODULE:
15.75/400 mm
15.75/400 mm
21.6/550 mm
75 lbs/34 kg
REGULATOR:
22/560 mm
16/406 mm
19/485 mm
165 lbs/75 kg
BASE:
36/915 mm
36/915 mm
9/230 mm
115 lbs/52 kg
CABLES:
All necessary interconnect power and control cables are supplied by PHENIX Technologies.
MODEL NUMBER:
4100-5ST-100
4200-5ST-100
4300-5ST-100
4400-5ST-100
4500-5ST-100
4600-5ST-100
INPUT: Voltage:
208-240 VAC
Current:
2.75 AAC
5.5 AAC
8.25 AAC
11 AAC
13.75 AAC
16.5 AAC
OUTPUT: Power:

Duty Cycle:

Voltage:

Current:

Polarity:

Ripple:
500 W
1000 W
1500 W
2000 W
2500 W
3000 W
30 Minutes ON / 60 Minutes OFF **
100 kV DC
200 kV DC
300 kV DC
400 kV DC
500 kV DC
600 kV DC
5 mA
POS / NEG
<0.2% per mA
METERING ACCURACY:
+1% F.S.
VOLTMETER RANGE:
0-100 kV DC
0-200 kV DC
0-300 kV DC
0-400 kV DC
0-500 kV DC
0-600 kV DC
AMMETER RANGE:
0 - 200 / 2000 / 10,000

DIMENSIONS/WEIGHT:
WIDTH
DEPTH
HEIGHT
WEIGHT

CONTROLS:
20/508 mm
14.5/370 mm
11/280 mm
42 lbs/19 kg
SINGLE HV MODULE:
16.5/420 mm
16.5/420 mm
27/686 mm
110 lbs/50 kg
REGULATOR:
22/560 mm
16/406 mm
26/660 mm
165 lbs/75 kg
BASE:
36/915 mm
36/915 mm
9/230 mm
115 lbs/52 kg
CABLES:
All necessary interconnect power and control cables are supplied by PHENIX Technologies.
SPECIFICATIONS*
Your Local Representative is:
75 Speicher Drive
Accident, MD 21520 USA
Tel: 301-746-8118
Fax: 301-895-5570
e-mail: info@phenixtech.com
Http://www.phenixtech.com
12/04