Rental Power
1500 kW
Description
This Cummins Power Generation rental package is a fully
integrated mobile power generation system, providing
optimum performance, reliability, and versatility for
standby and prime power applications
.
Features
Cummins diesel engines
Rugged 4-cycle industrial diesel delivers reliable power
and fast response to load changes.
Equipped with heavy duty air cleaners, bypass-type oil
filters, and additional fuel filtration.
Includes jacket water heaters for more reliable
operation in emergency standby applications.
Control system
The most advanced, reliable, and capable generator set
control system available in the market today.
Integrated generator set providing precise frequency
and voltage regulation, alarm and status message
display in one easy-to-operate customer interface.
Remote monitoring and operation ready.
Auto shutdown at fault detection.
Stamford alternators
Designed and built by Cummins Power Generation.
Voltage (480/277 VAC).
Oversized alternators for improved motor starting and
low temperature rise in prime and continuous
applications.
Permanent magnet excitation for improved
performance in cyclic and non-linear load applications.
Rental package enclosure
Designed for serviceability access.
Optimized fuel capacity.
Fluid containment design for greater environmental
protection.
Sound attenuated to minimize impact on local
environment.
Vertical cooling air and engine exhaust path to
minimize sound level adjacent to the container.
Equipped with 120 VAC and 24 VDC lighting.
Standby rating
Prime rating
Model
60 Hz
kW (kVA)
50 Hz
kW (kVA)
60 Hz
kW (kVA)
50 Hz
kW (kVA)
Engine model
Alternator
model
C1500D6R 1500
(1875)
1250 (1563)
KTA50-G9 P734-D1
Our energy working for you.
www.cumminspower.com
©2007|Cummins Power Generation|Specifications Subject to Change Without Notice
Cummins and PowerCommand are registered trademarks of Cummins Inc. AmpSentry is a trademark of Cummins Inc.
S-1545 (2/07)
Engine specifications
Engine model
KTA50-G9
Alternator data sheet
P734-D1
Engine data sheet
DS-6244
EPA Nonroad
Tier I (TPEM)
Design
4 cycle, V-block, turbocharged and low temperature after-cooled
Bore
158.8 mm (6.25 in.)
Stroke
158.8 mm (6.25 in.)
Displacement
50.3 liters (3067 in
3
)
Cylinder block
Cast iron, 60
o
V 16 cylinder
Battery capacity
8D (qty: 4) 1250 CCA @ 0° F and 1500 CCA @ 32° F
Battery charging alternator
24 volt 35 amp Delco Remy
Starting voltage
24 volt, negative ground
Fuel system
Direct injection: number 2 diesel fuel
Fuel filter
Dual element, 10 micron filtration, spin on fuel filters with water
separator. Additional Fleetguard Industrial Pro pre-filters
Air cleaner type
2-stage dry replaceable element with dust ejector
Lube oil filter type(s)
Five spin on element oil filter and 2 element bypass filter
Standard cooling system
45° C (113° F) @ 100 % prime and 40° C (104° F) @ 100 % standby
Alternator specifications
Design
Brushless, 4-pole, revolving field
Stator
Double layer lap 2/3 pitch
Rotor
Salient Pole, single bearing
Insulation system
Class F per NEMA MG1-1.65 and BS2757
Standard temperature rise
105/40
o
C standby
Exciter type
Brushless
Phase rotation
A (U), B (V), C (W)
Alternator cooling
Air Cooled-ICO1
AC waveform total harmonic distortion
Non distorting bal linear load <5%
Telephone influence factor (TIF)
<50 per NEMA MG1-22.43
Telephone harmonic factor (THF)
<3
Power capability specifications
Standby
rating
240 V, 1 phase Amps
208 V, 3 phase Amps
480 V, 3 phase Amps
600 V, 3 phase Amps
C1500D6R
N/A N/A 2255
amp
N/A
Electrical power panel specifications
Model voltage
120 V duplex
receptacles
240 V twist
Load lug connection
(stud diameter)
Load lug circuit
breakers
480 V
N/A
N/A
6 x 1/2 inch
2500 Amp
Site derating factors
Standby application: The engine may be operated at 1800 rpm up to 3400 ft (1036 m) and 104 °F (40 °C) without power
deration. For sustained operation above the conditions, derate by 4.5% per 1000 ft (300 m) and 10% per 18 °F (10 °C).
Our energy working for you.
www.cumminspower.com
©2007|Cummins Power Generation|Specifications Subject to Change Without Notice
Cummins and PowerCommand are registered trademarks of Cummins Inc. AmpSentry is a trademark of Cummins Inc.
S-1545 (2/07)
Standard protection functions
Voltmeter/ammeter phase selector
Warnings
High Coolant Temperature
High DC Voltage
Low Coolant Temperature
Low DC Voltage
Low Oil Pressure
Over Current
Overload Load Shed Contacts
Up to Four Customer Fault Inputs
Weak Battery
Overflow
Shutdowns
Emergency Stop
Fail to Crank
High AC Voltage
High Coolant Temperature
Low Coolant Level
Low AC Voltage
Low Oil Pressure
Overcurrent
Overspeed
Short Circuit
Underfrequency
Control system
PowerCommand control with AmpSentry
protection
Integrated automatic voltage regulator and engine
speed governor
AmpSentry protection guards the electrical integrity of
the alternator and power system from the effects of
overcurrent, over/under voltage, under frequency and
overload conditions
Control components designed to withstand the
vibration levels typical in generator sets
Standard control description
Analog % of current meter (amps)
Analog AC frequency meter
Analog AC voltage meter
Analog % of load meter (kW)
Cycle cranking control
Digital display panel
Emergency stop switch
Idle mode control
Menu switch
Panel backlighting
Remote starting, 12 volt, 2 wire
Reset switch
Run-Off-Auto switch
Sealed front panel, gasketed door
Self diagnostics
Voltmeter/Ammeter phase selector switch
Standard performance data warnings
High Coolant Temperature
High DC Voltage
Low Coolant Temperature
Low DC Voltage
Low Oil Pressure
Over Current
Overload Load Shed Contacts
Up to Four Customer Fault Inputs
Weak Battery
Overflow
Overspeed
Short Circuit
Underfrequency
Optional Features Shown
Our energy working for you.
www.cumminspower.com
©2007|Cummins Power Generation|Specifications Subject to Change Without Notice
Cummins and PowerCommand are registered trademarks of Cummins Inc. AmpSentry is a trademark of Cummins Inc.
S-1545 (2/07)
Ratings definitions
Standby:
Applicable for supplying emergency power for the
duration of normal power interruption. No sustained
overload capability is available for this rating.(Equivalent
to Fuel Stop Power in accordance with ISO3046,
AS2789, DIN6271 and BS5514). Nominally rated.
Prime (unlimited running time):
Applicable for supplying power in lieu of commercially
purchased power. Prime power is the maximum power
available at a variable load for an unlimited number of
hours. A 10% overload capability is available for limited
time. (Equivalent to Prime Power in accordance with
ISO8528 and Overload Power in accordance with
ISO3046, AS2789, DIN6271, and BS5514).
Dimensions
Model
Dim A
mm (in.)
Dim B
mm (in.)
Dim C
mm (in.)
Weight w/o fuel
kg (lbs)
Weight with fuel
kg (lbs)
Fuel capacity
liters (gal)
C1500D6R 12192
(480)
2438 (96)
2896 (114)
28000 (61729)
32008 (70565)
4800 (1268)
Specifications
Model
KW rating
Sound level
Tier rating
Hours of operation (75% load)
Standby
Prime
dB(A) @ 7 m
Standby
Standby
Prime
C1500D6R
1500
1250
88
Tier I (TPEM)
16
18
This generator set is designed in facilities
certified to ISO9001 and manufactured in
facilities certified to ISO9001 or ISO9002.
The Prototype Test Support (PTS) program
verifies the performance integrity of the
generator set design. Cummins Power
Generation products bearing the PTS symbol
meet the prototype test requirements of NFPA
110 for Level 1 systems.
Cummins Power Generation
1400 73
rd
Avenue N.E.
Minneapolis, MN 55432 USA
Telephone: 1 763 574-5000
USA Toll-free: 1 877 769 7669
Fax: 1 763 574-5298
C
A
B