RDC SERIES FlatPak
The FlatPak
TM
Series includes 28 VDC and 400 Hz con vert ers
designed for installation where space is limited. The units mount
at against a wall, and offer the smallest size to power-rating
ratio in the industry.
The output power rating for the 28 VDC FlatPak
TM
Power Sys tem
is 600 amps continuous and 2000 amps start current. The unit is
equipped with automatic line drop compensation to allow the use
of cables up to 60 feet in length without reducing the voltage at
the cable head. In addition, the FlatPak
TM
power sys tem meets
all Na tion al Elec tric Code (NEC) requirements for op er a tion with in
a hangar en vi ron ment.
In addition to xed equipment, Unitron offers 400 Hz, 28 VDC and
com bi na tion AC/DC units in mobile and towable con g u ra tions.
RDC SERIES FlatPak
TM
28 VDC POWER SYSTEM
STANDARD FEATURES:
MIL-STD-704E, ARP 5015, DFS 400 and
ISO 6858 Compliant
Indoor/Outdoor (Hangar/Ramp) Use
Automatic Input Line Monitoring
Automatic Line Drop Compensation
(ALDC)
Emergency Mushroom OFF Switch
Automatic Plug Head Regulation up to 60
Feet
Built-in Maintenance Diagnostics
Analog Control Panel
Current Limit Adjust
Output Voltage Meter and Ammeter
Internal Elapsed Time Meter
Front Panel Summary Fault Indicators
OPTIONS:
Alternate Input Voltages Available (specify)
Input Frequency 50 Hz
DC Output Power Cable with Plug (available in 30 or 60
foot lengths)
Front Panel Voltage Adjust (
±
15%)
Automatic Aircraft Safety Disconnect
Dual Output with Individual Safety Disconnect from Aircraft
Alternate Mounting Con gurations Available
WALL MOUNTED CONFIGURATION
Registered to ISO 9001:2000
GENERAL SPECIFICATIONS
INPUT:
Voltage
480 volts, ± 10%, 3Ø, 3 wire
plus
ground
Frequency
60 Hz ± 10%
Phase Rotation
Any
Protection
Over/undervoltage, loss of
phase,
overcurrent,
short
circuit
Inrush Current
No greater than 100% of full
load
current
MECHANICAL:
Size:
Depth: 16 in. (406 mm.)
Width:
25
in.
(635
mm.)
Height:
49
in.
(1245
mm.)
Weight:
360
lbs.
(163
kgs.)
Construction:
Indoor/Outdoor
Cooling: Forced
Convection
ENVIRONMENTAL:
Acoustical Noise
65 dBA maximum at 5 feet
Temperature Range
-40°C to +55°C
EMI/RFI
Compatible with aircraft
systems
OUTPUT:
Full Rated Load
600 amps continuous
Overload
125% for 7 minutes at
10%
duty
cycle
Engine Start Capacity
Adjustable up to 2000 amps for
20 seconds at 10% duty cycle
Voltage
28 VDC
Voltage Regulation
100% continuous
rat ed load and
± 10% in put voltage ± 0.05%
No load to rated
load
with
nominal
in put voltage
IAW ISO 6858
Overload with
nom i nal
input
volt
age
See start mode literature for
Model RDC-620
Voltage Adjust
28 VDC ± 15%
Current Limit Adjust
200 to 2000 amps
Protection
Overload, short circuit, and
over/undervoltage
REV. E
FIGURE 1
RDC SERIES FlatPak
TM
WALL MOUNTED
POWER SYSTEM
REV NC
*Analog Control Panel Shown