Y.MG325/452
A)
Exposue value B (mA*min)
100
300
0
100
150
200
250 300 350 400 450 kV
0
20
10
50
70
30
40
60
0
20
40
60
50
10
30
70
80
90
3,5
3
2,5
2
1,5
1
0,5
0
3,5
3
2,5
2
1,5
1
0,5
0
Fe (mm)
Fe (mm)
WPS (%)
WPS (%)
Radioscopic wire penetrameter sensitivity (WPS)
for Fe [%]
MG325 with Y.TU/ 320-D01,
focal spot: 1.9 mm acc. EN 12543 (0.8 acc. IEC336);
Distance focal spot - image intensifier: FDD = 800 mm;
Distance focal spot - object: FOD = 400 mm;
XRS 232: 7" size
Radioscopic wire penetrameter sensitivity (WPS)
for Fe [%]
MG452 with Y.TU/ 450-D02,
focal spot: 2.5 mm acc. EN 12543 (1.2 acc. IEC336);
Distance focal spot - image intensifier: FDD = 800 mm;
Distance focal spot - object: FOD = 500 mm;
XRS 232: 7" size
YXLON International X-Ray GmbH,
Essener Str. 99, Geb. 227, D-22419 Hamburg, Phone: +49 40 527 29 - 0,
Fax: +49 40 527 29 -170, E-mail: yxlon@hbg.yxlon.com, http://www.yxlon.com
®
Technical Data
Y.MU
2000
Technical Data
Y.MG325/452
YXLON.
The reason why
Y.MG325/452
YXLON.MG325/452
Universal Bipolar Constant Potential
X-Ray Systems
+T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnica
l Data +
The high energy and high dose rates of the bipolar
4.5 kW systems detailed below can be used for a wide
variety of applications ranging from light alloys and
thin walled materials of low density to thick walled
materials of high density such as 115 mm iron.
The bipolar 40 kHz X-ray systems feature very high
output stability, precise energy setting and extremely
fast change over to any selected new value. Any
fluctuation or deviation of set values is controlled and
corrected within microseconds.
These features make the system an excellent candidate
not only for radiographic and radioscopic applications
but also for scanning methods like tomography and
even in the field of dosimetry.
In addition these features reduce inspection times
considerably, an important economic aspect.
The wide range of use calls for a universal, easy to use
control system realized in the MGC41. The setup
modes are menu driven. All signals, operating mode
and fault diagnosis of internal or external errors are
displayed in clear text which can be easily displayed
in a number of optional languages. Additional error
indications are given by numerical codes. Furthermore,
100 technique programs can be stored for future use,
and when connected through the serial port interface,
an infinite number of programs may be stored on the
host computer.
All system components are protected against the
influence of dust and water. H.V Generators and Power
supplies meet the requirements of IP54.
YXLON. The reason why.
MG325 with
range selector
MG452 with
range selector
MG325
MG452
10
15
20
25
30
35
40
45
50
5
0
Live image
Integration
2 frames
Integration
64 frames
4
4,5
Live image
Integration
2 frames
Integration
64 frames
High output stability
Short inspection times
High reliability
Easy to use
Safety provisions
General
Two independent, independently monitored
safety-circuits (fail-safe, 24 V)
Continuous system functional monitoring with fully
automated system shut-down and failure indication
Automated filament post-heating H.V. capacitor
discharge upon termination
X-ray ON warning lamp monitoring provided (fail-safe)
Provided connections for:
External safety circuit for automated systems (24 V)
H.V. primary circuit interruption
for CDRH switch [US-Standard]
Monitored door lock feature
External coolant monitoring
Data subject to change without notice. Printed in Germany. 9499.211.00110.ED01
Our experience is available
for your specific inspection needs today!
MG325-E3 30.04.2004 11:58 Uhr Seite 1
YXLON-SYSTEM MG325
MG452
Max. Power:
4,500 W
High voltage:
Adjustment range (four-digit LED display)
15-320 kV
20-450 kV
Adjustment increments (minimum step)
0.2 kV / step
Accuracy
± 1 % of demand value ± 0.2 kV
Reproducibility
± 0.01 % of maximum kV-value at a constant temperature
H.V. ripple (with 10 m H.V. cable)
10 V/mA, min. 40 V
Temperature
induced drift
80 ppm/°C based on demand value
with compensation*
40 ppm/°C based on demand value (on request 30 ppm/°C possible)
Tube current:
Adjustment range (four-digit LED display)
0-22.5 mA
0-15 mA
Adjustment: Standard range
in 0.05 mA steps from 0.5 mA to maximum value
High resolution range (recommended)
in 0.01 mA steps from 0.0 mA to maximum value
Accuracy (at constant temperature)
± 0.2 % of demand value ± 0.01 mA
Reproducibility (at constant temperature)
± 2 µA
Temperature drift
50 ppm/°C of demand value (on request: 30 ppm/°C possible)
Focal spot selection:
Keypad selected: selection indicated by large and small symbols on display panel
Individual components:
Control unit:
Dimensions (WxHxD); Weight
MGC41: 483 mm x 133 mm x 300 mm; 12.5 kg
Power supply:
Dimensions (WxHxD); Weight
MGP41: 340 mm x 350 mm x 628 mm; 45 kg
H.V. generator (oil insulated)
MGG42 (-) / MGG43 (+)
MGG46 (-) / MGG47 (+)
Dimensions (WxHxD)
375 mm x 335 mm x 625 mm
514 mm x 364 mm x 624 mm
Weight
80 kg
125 kg
Metal-ceramic tube head (recommended)
Y.TU/320-D01, Y.TU/320-D03
Y.TU/450-D02, Y.TU/450-F02
Oil cooler:
oil to air heat exchanging system
OL4502: Dimensions (WxHxD) : 770 mm x 535 mm x 340 mm; Weight: 60.3 kg
oil to water heat exchanging system*
OW4500: Dimensions (WxHxD) : 621 mm x 560 mm x 350 mm; Weight: 65 kg
Chiller*
OLK50: Dimensions (WxHxD) : 1120 mm x 980 mm x 750 mm; Weight: approx. 191 kg
Additional components
High voltage cable and cooling hoses: standard length: 5 m, optional 10 m / 15 m / 20 m
* optional
+T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnical Data +++ T
echnica
l Data +
Operation
Constant potential with Isowatt-feature fully automated
monitoring of power limits and tube head specifications
Menu-driven system information input
Language selection:
English, German, French, Spanish
Serial interface
Tube head selection
Prewarning time
Display contrast
Hour counter
Service menu
History register (last 99 cycles)
Mains supply (single-phase)
230 V +10 %-15 %, 50/60 Hz
Protection MGP 41: 50 A
Exposure timer (four-digit LED display)
Input range
Special
setting for radioscopic application
In 1 second steps up to 10 minutes
In 10 second steps up to 99 minutes and 50 seconds
Pre-warning
Adjustable from 1 to 30 seconds
Menu-driven selection
Input through touch keypad
Tube head selection
Menu-driven through keypad entry
(see table for recommended tube head)
Programmed operation
100 technique capacity
(kV, mA, time, focal spot, programmable through
numeric keypad)
3-level program for automated tube conditioning
Environment
Duty cycle: 100 % at +40 °C max. ambient temperature in
non-convective air
Operation temperature: 0 °C to +40 °C,
relative humidity 90 % at +40 °C, non-condensing
Storage temperature: -25 °C to +70 °C,
relative humidity 95 % at +40 °C, non-condensing
Additional components
RS232C serial port for MGC41
MGC41 PC-Software
Range selector: MG452: 30 mA
MG352: 45 mA
Mobile tripod
Beam centering devices and sets of diaphragms
Tube mount
Additional options available on request
Compliance
YXLON International products are manufactured according to
strict safety and quality standards and in compliance with the
following standards:
DIN 54113 (radiation shielding and safety circuits)
EN 12543 (focal spot measurement standards)
German radiation regulations of 2002
DIN EN 60204/DIN EN 50178
EN 50082-2/EN 55011
USA: 21 CFR § 1020.40
47 CFR § 15 (FCC)
The quality management system of YXLON International
X-Ray GmbH is certified to DIN EN ISO 9001.
Minus
High voltage
generator
Mains
230 V
50/60 Hz
H. V. Cable
L. V. cable
Oil hose
Control unit
Power supply
Plus
High voltage
generator
X-ray tube
Oil cooler
Block diagramm for
bipolar constant potential
X-ray systems
MG325-E3 30.04.2004 11:58 Uhr Seite 3