b1750-11
page or responsible for its content.
b1750-11
Special
features
- Digital amplifier for industrial
automation tasks and
production process monitoring
- 600 Hz CF measurement
technology with TEDS sensor
recognition for SG full bridges
- Accuracy class, typically 0.05%
- Modular mounting on a DIN EN
50022 type DIN rail
- System bus with real-time
capability for up to 99 modules
- Standardized CANopen CiA
fieldbus coupling for
parameterization and backup
DF30CAN
digiCLIP
Data sheet
Address-
switch
(rotary)
LED
STATUS
LED BUS
Plug terminals: transducer
CANBUS plug terminal /
supply voltage
Amplifier modulel DF30CAN
Accessories: Connection module DF002
B1750-1.1 en
Specifications
DigiClip
Accuracy class (at U
B
= 2.5 V)
0.05, typically
0.1 in an industrial environment as per EN 61326, Annex A
Power supply
Supply voltage,
Overvoltage and reverse polarity protection
V
DC
24
Isolation voltage
Potential separation between the supply bus
and the transducer connection, functional sep-
aration, must not be used for safety consider-
ations
V
500
Permissible supply voltage range
V
18 ... 30
Influence of supply voltage when there are
changes in the specified range
%/V
< 0.001
Power consumption, max.; incl. transducer
W
1.5
Amplifier
Carrier frequency, square
Hz
600 (591.9 Hz "100 ppm)
Synchronization
when several interconnected modules are used, the carrier frequency is
synchronized automatically
Bridge excitation voltage UB,
Peak-to-peak ("10%)
V
2.5
1.0
Measuring range
mV/V
"4
"10
Connectable transducers
SG full bridge
ohms
80 ... 5000
Connection technique
4 and 6-wire circuitry with single-wire open-circuit monitoring
Permissible cable length between transducer
and amplifier, max.
m
100
Input resistance
MOhm
u5
Measurement frequency range, adjustable
(-3dB) (see filter table)
Hz
0.05 ... 225
Filter characteristics
Bessel, 4th order
Noise voltage relative to input, for UB = 2.5 V,
typical
礦/V
1.0 (at 100 Hz filter frequency)
0.05 (at 1 Hz filter frequency)
Influence of ambient temperature for change
of 10 K
on the zero point (TK0)
on sensitivity (TKC)
礦/V
%
0.1
0.05 f.s.
Linearity deviation
% f.s.
0.005
Long-term drift, without AutoCal
%
<0.001 (within 48 h)
Communication interface
Number of devices on the bus, max.
Address settings
Protocol
Hardware bus link
Baud rate
Max. line length
Baud rate selection
PDO transfer
Cycle time for time-driven triggering,
Possibly restricted by chosen data types and
filter frequency
1)
CAN connection
kBits/s
m
ms
99
1 to 99 via rotary switch on front
CAN 2.0B, CANopen-compatible, CiA DS301, DS404
Two-wire, as per ISO 11898
1000
500
250
125
100
50
25
100
250
500
600
1000
Automatic recognition after change of address
Triggered by sampling rate, timing control or SYNC message
0.85 ... 25000
Plug terminal on the side: potential separation from power supply and
measurement ground. Option: DF001: 9-pin sub-D (DIN 19245)
Signal conditioning
A/D converter
Delta-Sigma, 24-bit
Scaling accuracy
bits
32
Sampling rate
1/s
1184
1)
Floating point: 2 measured values at 0.85 ms; integers: 4 measured values at 0.85 ms; filters: see table overleaf
B1750-1.1 en
HBM
2
Input of characteristic curve
TEDS, calibration, editing
Zero balance
over the entire measuring range
Tare balance
over the entire measuring range
Duration of balancing
ms
< 2
AutoCal
ms
< 300
Parameter memory
1 set as per CiA DS404, protected in the EEPROM
Limit value switches
Definition
Number
Functions
Signal source (user-selectable)
Hysteresis
Update
as per CiA DS404, ALARM block
4
Switching threshold, hysteresis (2-point control), greater than, less than
gross, net, max, min, peak-to-peak
adjustable over the entire measuring range
at each measured value
Peak-value memory
Number
Function
Update
Clearing peak-value memory
Retaining the current measured value/peak
value
Current-value memory
ms
ms
3
min., max., peak-to-peak
at each measured value
< 2
< 2
Run /Hold
Ambient conditions
Nominal temperature range
o
C
0 ... +50
Operating temperature range
o
C
-10 ... +60
Storage temperature range
o
C
-20 ... + 70
Permissible rel. humidity, non-condensing
%
10 ... 90
Housing
Material
Polyamide PA 6.6
Dimensions (WxHxD)
without connections
mm
23 x 100 x 114
Weight, approx.
g
150
Mounting
Support rail, DIN EN 50022
Connection
Plug-in terminals
Degree of protection
IP20
Reliability
MTTF (MIL-HDBK-217F, Feb. 1995)
hours
125000
EMC conformance
as per EN 61326
*)
in an industrial environment
* With measurement per EN 61326, May 2004 edition, Annex F, burst to shielding of the transducer or bus line, the class accuracy of 0.1 is
complied with when using filter frequencies up to 2 Hz. When a filter frequency of 100 Hz is used, the measurement variation can be as much
as 1.3%.
Filter data and sampling rate
Desired
frequency
-1 dB (Hz)
-3 dB (Hz)
-20dB (Hz)
Phase delay
(ms)
Sampling rate
(s
-1
)
Min. cycle time (ms)
100 Hz
130
225
560
2.3
1184
0.85
50 Hz
48
82
220
4.6
1184
0.85
20 Hz
20
34
100
9.5
1184
0.85
10 Hz
10.5
18.6
56
16.6
1184
0.85
5 Hz
5.2
9.3
28
31
592
1.7
2 Hz
2.1
3.7
11.2
70
237
4.2
1 Hz
1.05
1.8
5.6
140
118
8.4
0.5 Hz
0.52
0.9
2.8
280
59
16.9
0.2 Hz
0.21
0.36
1.1
700
24
42.2
0.1 Hz
0.105
0.18
0.56
1400
12
84.5
0.05 Hz
0.052
0.09
0.28
2800
6
168.9
B1750-1.1 en
HBM
3
Block diagram
礟
A D
Intelligent signal
conditioning
Address switch
01 ... 99
CF transducer
excitation with
sense leads
Status
bus
LED
display
CANopen
interface
Supply voltage
18 - 30 VDC
electrically
isolated
TEDS
RAM /
EEPROM
Calibration
Linearization
Parameter memory
Zero balance
Min./Max. memory
Limit value switches
AutoCal
electrically
isolated
Dimensions
Dimensions (in mm)
22.6
29.2
107
93.1
30.55
99
6.6
Scope of supply
:
digiCLIP module
Order no.: 1-DF30CAN
Coded connectors for sensor connection (2 pieces)
Order no.: 3-3312.0404
Plug terminal for CANBUS and supply voltage
Accessories
(not included in the scope of supply):
Setup toolkit for digiCLIP (USB-to-CAN interface converter, connection cable, free setup software)
digiCLIP Assistant) (a free, updated version of the Assistant can be download at
http://www.hbm.com/support)
Order no.: 1-DIGICLIP-SETUP
Connector set for digiCLIP modules
(needed for two-tier installation in the control cabinet)
Order no.: 1-digiCLIP-ST
Connection module for frontal assignment of the
rear terminal strip (bus and voltage supply)
Order no.: 1-DF002
Hottinger Baldwin Messtechnik GmbH
Postfach 10 01 51, D-64201 Darmstadt, Germany
Im Tiefen See 45, D-64293 Darmstadt, Germany
Tel.: +49 61 51/ 8 03-0; Fax: +49 61 51/ 8039100
E-mail:
support@hbm.com
www.hbm.com
Modifications reserved.
All details describe our products in general form only. They
are not to be understood as express warranty and do not
constitute any liability whatsoever.
B1750-1.0 en