Differential Pressure Transducers

ential
Pressure Transducer for
PLUGSYS Amplifier
Specifications
Pressure Range
±100 cmH
2
O (±100 mbar)
Sensitivity
0.3 to 0.8 mV/mbar, excitation of 5 V
Linearity
±1.5%
Thermal Zero Shift
5 mbar (0° to 85°C)
Input Resistance
400 to 550 Output Resistance
600 to 1000 Offset Voltage
1 mV maximum
Excitation Voltage
0 to 5 VDC or AC
Overpressure
±1000 mbar (750 mmHg)
Inlet/Outlet Nozzle
2.0 x 4.7 x 9.0 mm, ID x OD x L
Housing Size, H x W x D
24 x 42 x 36 mm (0.9 x 1.7 x 1.4 in)
Weight
190 g (6.7 oz)
Application
Only for dry air
Catalog No.
$
Product
BS4 73-0064
387.00
Differential Pressure Transducer MPX,
for PLUGSYS
BS4 73-3108
500.00
Differential Pressure Transducer MPX,
for Harvard Apparatus
BS4 73-3109
609.00
Differential Pressure Transducer MPX,
for Grass
BS4 73-3110
500.00
Differential Pressure Transducer MPX,
for Gould 6600
BS4 73-3111
655.00
Differential Pressure Transducer MPX,
for Gould 4600
Specifications
Ranges
DP 45-14 ±2 cm H
2
0
(PTM and FLEISCH
tube)
Volumetric displacement 0.006 mm
3
FS
Natural frequency
< than 600 Hz
Measuring System
Half bridge inductance
(2 x 20 mH nominal)
Pressure cavity volume 6.5 mm
3
Excitation voltage
5 V at 5 kHz
Thermal zero shift
0.2%/10°K (25°C
±40°K)
Sensitivity
25 mV/V FS nominal
Accuracy
±0.25% FS
Size, OD x Width
57 x 20.5 mm
Weight
0.6 kg Ideal for measuring esophageal pressure with
air-filled catheter, mouth pressures and transdi-
aphragmatic pressures For use with most research animals
This differential pressure transducer is mainly used for
measuring esophageal pressure using air filled catheter.
It is ideal for use with mouse, hamster, rat, guinea pig,
rabbit, ferret, cat and dog.
This Differential Pressure Transducers is for
very low differential pressure measurements.
They are especially suitable for applications in
plethysmography and pneumotachography.
This Transducer has very small internal vol-
ume and volumetric displacement to achieve
high frequency response. It is highly resistant
to mechanical shock and over-pressure. A
diaphragm of magnetically permeable materi-
al clamped between two symmetrical assem-
blies completes a magnetic circuit with each E-
core. Application of pressure causes
diaphragm deflection, increasing the gap in
the magnetic flux path of one core and
decreasing the gap equally in the other core.
The magnetic reluctance varies with the size of
the gap, changing the inductance ratio. The
inductance ratio is then measured by an
Carrier Frequency bridge amplifier in which
an output voltage proportional to pressure is obtained. The CFBA Amplifier for the
PLUGSYS or a regular bridge amplfier in combination with the Carrier Frequency
Adapter Box on can be used.
All
exposed parts of these Transducers are made from 410 stainless steel to prevent
corrosion. They have a 3.1 m (10 ft) cable and are supplied individually with two
pieces of 4.8 mm (0.31 in) ID hose for connection to a Pneumotachometer, see
pages F40 to F41. Interchangeable Replacement Diaphragms are offered separately
to change the Transducers operating pressure range. For very low differential
pressure measurements Suitable for applications
in plethysmography,
pneumotachography Highly resistant to mechani-
cal shock and overpressure All exposed parts made
from 410 stainless steel to
prevent corrosion For connection to
pneumotachometer
FLEISCH or HSE - PTM or
plethysmograph box Range
±
2 cm H
2
0 Inductive system, needs
CF-bridge Amplifier (or
CFAB with DC-bridge
amplifier)
BS4 73-0064
.
Differential Pressure Transducer
MPX, for PLUGSYS Amplifier
Catalog No.
$
Product
BS4 73-0838
1,492.00
Differential Pressure Transducer Validyne Type 45-14
BS4 73-0500
140.00
Stand with Triangular Plate
HSE-HA Differential
Pressure Transducer
Interchangeable Replacement Diaphragms
to BS4 73-0838 are offered separately
to change the Transducers
operating pressure range.