30003000

sults for ""
Below is a cache of http://lib.store.yahoo.net/lib/aaaremotes/AGS3000.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
30003000 pg
1 pg 2
General Information.................................................................................................................3
Features...................................................................................................................................5
Parts Identification...................................................................................................................6
Installation................................................................................................................................8
Pg.
Contents
Master and Slave...................................................................................................................18
Wiring Diagrams....................................................................................................................19
Fine Tuning............................................................................................................................17
Electrical................................................................................................................................13
Alternate Installation..............................................................................................................12
Options..................................................................................................................................23
Safety Edge...........................................................................................................................21
Maintenance and Safety........................................................................................................25
Trouble Shooting....................................................................................................................26
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING-To reduce the risk of severe injury or death:
1) READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2) Make sure that the gate is properly installed. An improperly installed door could cause severe
injury. Have a qualified service person make repairs to the gate and other hardware before installing
the opener.
3) Do not connect the opener to source of power until unstructed to do so.
4) Locate the control button: (a) within sight of the door, (b) at a minimum hight of 5 feet so small
children cannot reach it, and (c) away from all moving parts of the door. pg 3
General Information
m
m
m
m
m
OVERALL DIMENSIONS:
Height: 21" (53 cm) Length: 12" (30 cm) Width: 17" (43 cm)
m
m
m
m
m
SHIPPING WEIGHT:
140 pounds (64 kg)

l
Options:
Steel Mounting Stand: 23 pounds (10 kg)
m
m
m
m
m
POWER REQUIREMENT:
Dedicated 115 Volt AC (+/- 10V), 5 AMP Power Circuit
m
m
m
m
m
APPLICATIONS:
l
Maximum Gate Weight:
1,500 pounds (680 kg)
l
Maximum Gate Length:
40 feet (12 m)
l
Maximum Gate Speed:
10in/sec (12in/sec also available)
m
m
m
m
m
INCLUDED WITH OPERATOR:
l

40-Feet of # 41 Roller Chain
l

2-Master Links # 41
l

2-Zinc Plated Chain Bolts
l

2-Chain Brackets, Right and Left
l

2-U-Bolts, Round (for chain brackets)
l

2-U-Bolts, Square (for chain brackets)
l

1-Caution Safety Sign
l

1-Hex Wrench 5/16"
l

1-Instruction Manual
l

1-Flexible Conduit End Fitting 1/2"
l

4-Sleeve Anchor Bolts (red heads) 3/8" X 3"
l

1-Hex Bolt with Nut, 1/4"-20
l

1-Self Tapping Screw, 1/4"-20
BASE PLATE HOLE PATTERN pg 4
m
m
m
m
m
CIRCUIT BOARD:
The AGS 3000 uses the Full Systems Capability circuit board, a powerful
control system which is used on many other AGS gate operators. This circuit board operates on 12 ~
18 Volts and can deliver power to the motor through high power external switching. The limit switch
input terminals require the use of normally open type limit switches. These switches are used to
accurately stop the gate operator in the open and closed positions. To safeguard the operator from
damage that could result from limit switch or gate sensitivity failure, the Full Systems Capability circuit
board has a built-in maximum run timer which will allow the operator to run for approximately 40
seconds and then shut off automatically. The Full Systems Capability circuit board has an adjustable
gate sensitivity feature which will stop or reverse the gate if the gate is pushing harder than normal
because of an obstruction.
m
m
m
m
m
GATE SENSITIVITY:
The AGS 3000 Full Systems Capability circuit board has a built-in safety
feature which when adjusted properly will deliver only enough power to the motor to overcome the
resistance of the gate. The amount of power that the circuit board will deliver can be adjusted for both
directions of travel to accommodate the various gate weights that the AGS 3000 operator is
recommended for. (See Applications Pg. 3)
m
m
m
m
m
PERIPHERALS:
POWER SUPPLY: There is 12 VDC available on terminals 8 and 12 which is used to supply
power to a radio receiver.
OPEN INPUT: Normally open devices are connected to terminals 5 and 6, Open Input to
cause the gate operator to open and/or hold open the gate. This input is also used to close the gate
when the AUTO CLOSE TIMER switch is OFF, (See OPERATION).
PULSE OPEN INPUT: Normally open devices are connected to terminals 6 and 7 Pulse Open
Input to cause the gate operator to open the gate. This input functions identical to the Open Input with
the exception that if the input remains present, the Auto Close Timer will still close the gate. (See
AUTO CLOSE TIMER) The Pulse Open Input cannot be used in Push-To-Open/Push-To-Close
mode (timer off), it will not close the gate. These normally open devices that are used on the Open
Input or the Pulse Open Input can be push buttons, radio receivers, key switches, loop detectors,
photo electric beams, 24 hour timers, etc.
SAFETY INPUT: Normally open devices are connected to terminals 4 and 8 on the AGS 3000
Full Systems Capability circuit board to cause the gate operator to reverse and/or hold the gate open
in any position except the fully closed position. Normally open safety input devices that can be used
are push buttons, radio receivers, key switches, loop detectors, photo electric beams, 24 hour timers,
etc.
STOP INPUT: Normally closed devices are connected to terminals 8 and 9 on the AGS 3000
Full Systems Capability circuit board to cause the gate operator to stop in any position. This stop
input can be used as a simple safety device for pedestrian doors which may interfere with the gate's
operation. When the stop input is used, the operator will stop and remain stopped until the stop circuit
has been re-closed and until given an open input on terminals 5 and 6. Normally closed stop input
devices that can be used are push buttons, key switches, loop detectors, photo electric beams, 24
hour timers, etc.
CLOSE INPUT: Normally open devices are connected to terminals 8 and 10 on the AGS 3000 Full
Systems Capability circuit board to cause the gate operator to close the gate when in any position.
Normally open input devices that can be used are push buttons, radio receivers, key switches, loop
detectors, photo electric beams, 24 hour timers, etc.
General Information continued... pg 5
Features
m
m
m
m
m
OPERATION
The AGS 3000 Full Systems Capability can operate in a AUTO CLOSE TIMER (TIMER ON) or
a PUSH-TO-OPEN/PUSH-TO-CLOSE (TIMER OFF) mode of operation. In the AUTO CLOSE TIMER
mode of operation the operator is given a command to open the gate and hold it open until the input
is released and until the auto close timer has elapsed at which point the operator will close the gate
automatically. In the PUSH-TO-OPEN/PUSH-TO-CLOSE mode of operation each time a signal is
sent to the operator, it will cause it to do the opposite of what it did before. (i.e., If the gate is closed, it
will start opening, if it is open, it will start closing: If it is closing, it will REVERSE TO OPEN, if it is
opening, it will REVERSE TO CLOSE.)
m
m
m
m
m
CONTROLS
The AGS 3000 Full Systems Capability works with the following control devices: Radio
transmitters and their receiver (specified by and available from the manufacturer). Key switches,
Push buttons (separate or intercom), numerical key pads and any peripheral equipment which can
supply normally open or normally closed contacts. These contacts can be connected to the operator
input terminals to perform the opening, close, safety, or the stop functions.
m
m
m
m
m
AUTO CLOSE TIMER
The operator comes factory preset with the auto close timer turned OFF. The auto close timer
will close the gate automatically after a specific amount of time has elapsed. The amount of time can
be easily adjusted between 0 and 45 seconds by turning a small "pot" located on the right edge of the
circuit board (See page 12). The timer can be disabled or activated by flipping a single switch located
on th