SYNTHESIS

r> Yahoo! is not affiliated with the authors of this page or responsible for its content.
SYNTHESIS
SYNTHESIS
SINGLE PHASE
115 V 0.2 - 0.4
K
W
230 V 0.2 - 2.2
K
W
THREE PHASE
400 V 0.75 - 2.2
K
W
MANAGEMENT SER
VICE
UNI EN ISO 9001
Certificato n
°
50 100 0125
ISO 14001
N990 SPECIFICATION
Mounting dimensions
Inverter SYN10
S 115 and S 220 AF 01/03/05
S 220 AF 07/09
S 400 AF 05/07/09
IP65 NEMA 4 Version
S 220 AF 01/03/05 with switch
S 220 AF 01/03/05 without switch
W
W1
H
H1
D
72
118
141
141
61
108
124
124
131
143
216
216
116
127.5
199
199
118
172
183
170
Braking resistor selection
Inverter model
SYN10 S 220 07/09 AF
SYN10 T 400 05 AF
SYN10 T 400 07 AF
SYN10 T 400 09 AF
Braking mod. built-in
Yes
Yes
Yes
Yes
Braking resistor
SR-0.75-S
SR-0.75-T
SR-1.5-T
SR-2.2-T
Class B EMI filter book size mounting
Inverter model
SYN10 S 220 01 AF
SYN10 S 220 03 AF
SYN10 S 220 05 AF
SYN10 S 220 07 AF
SYN10 S 220 09 AF
SYN10 T 400 05 AF
SYN10 T 400 07 AF
SYN10 T 400 09 AF
FT1000-0.4-S
FT1000-0.75-S
FT1000-2.2-S
FT1000-0.75-T
FT1000-2.2-T
Filter model
Dim. (mm) LxAxP Curr. (A)
36x189x71
36x191x110
41x191x174
41x191x110
41x191x110
6.5
18
29
5
10
SYN10
S
Inverter series
220
05
AF
IP65
S
Input phases
Power voltage
Rated power
EMC
filter
Protection degree Input main switch
S = single phase
T = three phase
115 = 115V
220 = 220V
400 = 400V
01 = 0.2 kW
03 = 0.4 kW
05 = 0.75 kW
07 = 1.5 kW
09 = 2.2 kW
AF = class A filter
_ = IP20
IP65 = IP65
_ = without
switch
S = with switch
(IP65 only)
Sample model identification
IP20
IP65
W
H
H1
hole
center
distance
D
W1
hole center
distance Functional specifications
SYNTHESIS
Protection functions
Suitable Motor Power Rating (kW)
Motor (HP)
Output Current (A)
Capacity (KVA)
Weight (Kg)
Input Voltage Max.
Output Voltage Max.
Dimensions LxAxP (mm)
EMC specification
Input Signal Type
Control Method
Freq. Range
Resolution Setting
Keyboard Setting
External Signal Setting
Other function
Carrier frequency
Accelerate/Decelerate time
V/F Pattern
Torque control
Multi-Functional input
Multi-Functional output
Braking Torque
Other function
Display
Operating temperature
Humidity
Vibration
EMC specification
UL
Overload protection
Over-voltage
Under voltage
Momentary Power-loss
Stall Prevention
Output Short-circuit
Grounding fault
Other function
Installation
72x132x118
118x143x172
01
0.2
1/4
1.4
0.53
0.7
03
0.4
1/2
2.3
0.88
0.72
01 AF
0.2
0.25
1.4
0.53
0.76
03 AF
0.4
0.5
2.3
0.88
0.77
05 AF
0.75
1
4.2
1.6
0.8
07 AF
1.5
2
7.5
2.9
1.66
09 AF
2.2
3
10.5
4.0
1.76
05
AF
0.75
1
2.3
1.7
1.6
Single phase
100-120V
Single/Three phases
200-240V
Three phases
380 - 460V
Three phases 200 - 240V
Class A (built in three phase filter)
PNP type (SOURCE) input (External 24VDC Input allowed)
Sinusoidal wave PWM control
1~200 Hz
Digital: 0.1 Hz (1 ~ 99.9 Hz); 1 Hz (100 ~ 200 Hz); Analog: 1Hz/ 60 Hz
Directly setup by and buttons.
0~10V, 4 ~ 20mA, 0 ~ 20mA
Frequency
upper and lower limit
4~16KHz
0.1~ 999 Sec
6 Patterns
Torque boost level adjustable (manual torque boost)
2 point, to be used as multi-speed 1(Sp.1) / multi-speed 2(Sp.2) / Jog /
External emergency stop / External bb / Reset
1a Relay terminal, to be setup as Fault / Running / Frequency.
S220 01 and 03: about 20%; S220 05, 07, 09 and T400: 20%~100% built-in braking transistor
Decelerate or free run stop, Auto reset, DC braking frequency / Voltage /
Time can be setup by constants.
Three digital LED display frequency / inverter parameter / fault record / program version.
-10 ~ +40
°
C (with cover removed: -10OC ~ +50OC)
0~95% RH non-condensing.
Under 1 G (9.8 m/s
2
)
EN5008-1, EN5008-2, EN50082-1, EN50082-2, EN50178
UL508C
150% for 1 min.
DC voltage > 410V(200 series); DC voltage > 800V(400 series)
DC voltage < 200V(200 series); DC voltage < 400V(400 series)
0 ~ 2 sec: The inverter can be restarted using speed search feature.
During Acceleration / Deceleration/ Constant speed
Electronic circuitry protection
Electronic circuitry protection
Heat sink overheat protection, Current limit
Mounting screw or DIN rail (Option).
SYN10
S115
S220
T400
07 AF
1.5
2
3.8
2.9
1.62
09 AF
2.2
3
5.2
4.0
1.68
Single phase
200-240V
Variations: voltage (+10%, -15%), frequency 50/60 Hz (+/-5%)
Three phases 380 - 460V
Proportional to input voltage
Main features
Freq. control COD. VEC 112 R0
VECTRON Elektronik Gmbh
Europark Fichtenhain A 6 47807 Krefeld - Germany
Tel. (0 21 51) 83 96-30 - Fax (0 21 51) 83 96-99
www.vectron.net
e-mail: info@vectron.net
Bonfiglioli Riduttori SpA
Via Giovanni XXIII, 7/A - 40012 Lippo di Calderara di Reno - Bologna (Italy)
Tel. (+39) 051 6473111 - Fax (+39) 051 6473126
www.bonfiglioli.com - e-mail: bonfiglioli@bonfiglioli.com
Accel. Time
Decel. Time
Operation mode
Motor rotation direction
V/F Pattern
Frequency upper/lower limit
SPI frequency
JOG frequency
Start / Stop Control
Frequency Control
Carrier frequency control
Torque compensation
Stop method
DC braking setting
Electronic thermal
Overload protection
Multifunction input
connection point
Multi-function output
Reverse Lock-Out
Momentary power loss
Auto restart
Factory setting
SP2 frequency
SP3 frequency
Direct start
Software version
Fault Log
Function
F_
Function description
Unit
Range
Factory setting
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Factory Adjustment
Acceleration time
Deceleration time
0: Forward / Stop, Reverse / Stop
1:Run/Stop, Forward / Reverse
0: Forward
1: Reverse
V/F pattern setting
Frequency upper limit
Frequency lower limit
SP1 frequency
JOG frequency
0: Keypad
1: Terminal (TM2)
0: Keypad
1: Terminal (0~10v / 0~20mA)
2: Terminal (4~20mA)
Carrier Frequency Setting
Torque compensation gain
0:controlled deceleration stop
1:free run to stop
DC braking time
DC braking injection frequency
DC braking level
Protection base on motor rated current
Multifunction input terminal 1 (SP1) function
Multifunction input terminal 2 (RESET) function
Multifunction output terminal
0: REV run
1: REV run Lock-Out
0: enabled
1: disabled
Number of Auto-restart times
010: Constants initialization to 50Hz system
020: Constants initialization to 60Hz system
SP2 frequency
SP3 frequency
0:enable
1:disable
CPU program version
Fault log for three faults
0.1Sec
0.1Sec
1
1
1
0.1Hz
0.1Hz
0.1Hz
0.1Hz
1
1
1 khz
0.1%
1
0.1S
0.1Hz
0.1%
1%
1: Jog
2: Sp1
3: Quick stop
4: External Base Block
5: Reset
6: SP2
1: Operating
2: Frequency reached
3: Fault
1
1
1
0.1Hz
0.1Hz
1
0
5.0
5.0
0
0
1/4
50/60Hz
0.0Hz
10Hz
6Hz
0
0
5
0.0%
0
0.5S
1.5Hz
8.0%
100%
2
5
3
0
0
0
20
30
1
0.1 ~ 999 S
0.1 ~ 999 S
0 ~ 1
0 ~ 1
1 ~ 6
1.0 ~ 200Hz
0.0 ~ 200Hz
1.0 ~ 200Hz
1.0 ~ 200Hz
0 ~ 1
0 ~ 2
1 ~ 10
0.0 ~ 10.0%
0 ~ 1
0.0 ~ 25.5S
1 ~ 10Hz
0.0 ~ 20.0%
0 ~ 200%
0 ~ 1
0 ~ 1
0 ~ 5
1.0~200Hz
1.0~200Hz
0 ~ 1
Parameter list 1000 Worldwide Boulevard Hebron, KY 41048-8632
859-334-3333 Fax: 859-334-8888 www.bonfiglioliusa.com