Relay Timer Types Energy Efficient Lighting Management with CAT-5 Connectivity
Relay Timer Types
General Notes
Any Timer may control any or all Relay Outputs
Timers may cause Relay Outputs to be turned ON or OFF
Any Timer may control any or all Group(s) of Relay Outputs
Timers may cause Group(s) of Relays Outputs to be turned ON or OFF
Timer may cause any Preset(s) to be activated
HID Delay:
The relays designated as HID
Delay Timer operation will
observe the blink alert
waiting period and an
override without blinking
(turning OFF and ON) the
HID fixture
OFF: The OFF Timer Function will Turn OFF Relay Outputs
assigned to a specific Timer.
Alarm ON:
Relays are capable of
performing a momentary ON
function. Relays programmed
for this function will turn ON for
a programmed duration
(1 to 99 seconds) and then
return to the OFF state.
Application: Mechanically
Latching Contactor
Alarm Pulsed ON:
During the ON pulse period
(1 to 99 seconds program-
mable) the relay is cycled
ON and OFF at 1 second
intervals). Relay returns to
OFF state when complete.
Application: Alarm or buzzer
signal applications, class-
room bell systems. Used in
conjunction with HID appli-
cations for settable blink
alert operation.
Alarm OFF:
Relays
are capable of
performing a momentary OFF
function. Relays programmed
for this function will turn OFF
for a programmed duration
(1 to 99 seconds) and then
return to the ON state.
Application: Sentry Switch or
The Watt Stopper
®
AS-110
Automatic Control Switch
compatible
Alarm Pulsed OFF:
During the OFF pulse period (1
to 99 seconds programmable)
the relay is cycled OFF and
ON at 1 second intervals).
Relay returns to ON state
when complete.
Application: Settable blink
alert operation.
Open/Closed Time Control:
Relay Groups or Timers may
be controlled in relation to
OPEN/CLOSE times of the
facility. The open/closed
times may vary for different
days per day of the week
and may be programmed
for each day of the year if
necessary.
Power-Up State:
Relays may be configured
to provide one of the fol-
lowing functions at power-
up of the controller ON, OFF,
ON if Input 1 closed, OFF if
input 1 closed or NO
ACTION. (Input 1 may be
wired to a security or fire
alarm system as an output
override)
ON: The ON Timer Function will Turn ON Relay Outputs
assigned to a specific Timer.
OFF with Blink: Each relay output within the LightMaster may
be individually programmable to blink (OFF/ON) prior to being
turned OFF by a Timer. This will warn occupants of the upcom-
ing OFF event. The time window from the blink alert to the
scheduled OFF time are adjustable between 2 and 99 minutes
in 1-minute increments. If an ON command is received during
the blink alert time the relay output will be overridden and left
ON for the override time. Override times are adjustable from 5
to 999 minutes in 1-minute increments.
Special Application Timer/Relay Types:
Standard Timer/Relay Types:
After Hour Timer OFF Sweeps:
To minimize the programming
of after hours OFF sweeps, the
user may specify a after Close
and before Open time win-
dow, and OFF sweeps will
occur every 1, 2 or 3 hours
automatically
CS0002_revB