AKR-1
B. MEAD BOND - SIZE: 7.000 X 4.750 - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
CONTENTS
PRODUCT DESCRIPTION
Linears AKR-1 is a digital keyless entry system with a built-in radio receiver
designed for access control applications. The keypad is housed in a rugged, cast
aluminum enclosure that can be mounted to a pedestal or bolted directly to a wall.
The die-cast keys have bright, easy-to-read yellow graphics.
Up to 480 entry codes, from 1 to 6 digits in length, can be programmed. They
can activate either, or both, of the relay outputs. Relay #1 has a 5 Amp capacity.
Relay #2 has a 1 Amp capacity.
Up to four sets of block coded MegaCode
®
transmitters (up to 480 transmitters
total) can be used to gain access through the AKR-1s built-in radio receiver.
Each transmitter can be individually suspended or re-activated. Four facility codes
can be programmed to identify each block of transmitters. A Radio Test Mode is
provided for testing transmitters and detecting radio interference. Programming of
individual (non-block coded) transmitters is not supported by the AKR-1.
Linears Model MGT safety edge transmitter is compatible with the AKR-1. This
supervised transmitter is used to detect and transmit obstacle events to the AKR-1
receiver. Obstacle signals from an MGT transmitter will activate Relay #2.
Two indicators show the status of the entry system. The left indicator lights red to
indicate power, then turns green when access is granted. The right indicator lights
yellow when the keypad is in lockout condition (from too many incorrect code
entries). The keypads courtesy light illuminates the keys for two minutes after any
key is pressed. An internal sounder beeps when each key is pressed and when a
transmitter is granted access. An internal jumper sets the sounder volume high or
low.
The DOOR SENSE/INHIBIT input can be used two ways. If programmed for
door sense, a switch on the door detects forced entry or door ajar situations. If
programmed for inhibit, the input can be wired to a service switch or automatic
timer that will disable the Relay #1 when required.
The REQUEST-TO-ENTER input can be wired to a pushbutton or re access
keyswitch to provide codeless entry for authorized personnel.
The anti-passback feature prevents using the same code or the same transmitter
again before the programmed time elapses.
The ALARM SHUNT output activates when access is granted. This output can be
wired to shunt alarm contacts on the access door/gate to prevent triggering of an
alarm when authorized access occurs.
Two solid state outputs, capable of switching 100 mA to common, are programmable
to signal forced entry, door ajar, lockout, alarm circuit shunting, request-to-enter,
and keypad active conditions.
The AKR-1 is powered from a 12-24 Volt AC or DC source. Power can be obtained
from the access device or a separate power supply. The EEPROM memory retains
all entry codes, transmitter information, and programming, even without power. An
internal jumper is provided to reset the master code.
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COMPONENT LOCATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FACTORY DEFAULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
BASIC PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
PROGRAMMING OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RADIO PROGRAMMING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AKR-1 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
MGT OBSTACLE TRANSMITTER OPERATION . . . . . . . . . . . . . . . . . . 16
RADIO TEST MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LINEAR LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
IMPORTANT !!! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
FCC NOTICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
217350 D IMAGE 2
1
FEATURES
KEYPAD PROGRAMMABLE
480 ENTRY CODE CAPACITY
480 TRANSMITTER CAPACITY
SUPPORTS 4 BLOCKS OF TRANSMITTERS WITH 4 FACILITY CODES
WEATHER-PROOF, TAMPER-RESISTANT RADIO ANTENNA
SUPPORTS 1 MODEL MGT SAFETY EDGE TRANSMITTER
1-6 DIGIT ENTRY CODE LENGTH
4 INDEPENDENT OUTPUTS (TIMED/TOGGLED)
4 INDEPENDENT TIMERS
EACH ENTRY CODE CAN BE PROGRAMMED TO ACTIVATE EITHER OR BOTH RELAYS
RELAY CONTACTS ARE FORM C (N.O. & N.C)
SOLID STATE OUTPUTS ARE OPEN COLLECTOR (SWITCH-TO-COMMON)
TWO STATUS INDICATORS
COURTESY LAMP
PIEZO SOUNDER
TIMED ANTI-PASSBACK (LAST 3 VALID ENTRIES)
KEYPAD LOCKOUT
TACTILE KEY FEEL
DOOR SENSE INPUT
INHIBIT INPUT
REQUEST-TO-ENTER INPUT
INSTALLATION
To avoid damage to the unit from static discharges, connect the
EARTH GROUND terminal to a good earth grounding point. Suggested
wiring size is 18 AWG for earth ground and power (up to 500 feet
of 18 AWG wire can be run for power, use larger wire for longer
runs). Use 22 AWG or larger (depending on the load) for all other
connections.
CAUTION: If the unit is AC powered, and one side of
the power transformer secondary is connected to earth
ground, connect the grounded side to the - power
terminal of the unit.
Select a location for the keypad. For door access control installations,
mount the keypad near the controlled door. For gate control
installations, mount the keypad in clear view of the gate, but far
enough from the gate so the user cannot touch the gate from the
keypad.
WARNING: TO AVOID SERIOUS INJURY OR DEATH,
MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM
THE GATE SO THAT THE USER CANNOT TOUCH THE
GATE WHILE OPERATING THE KEYPAD. HOWEVER,
THE GATE MUST BE FULLY VISIBLE FROM THE
KEYPAD.
217350 D IMAGE 3
2
COMPONENT LOCATIONS
RED/GREEN
POWER/ACCESS
INDICATOR
NIGHT
LIGHT
TACTILE
KEYPAD
YELLOW
"LOCKOUT"
INDICATOR
KEYLOCK
JUMPER JP1
REMOVE TO
REDUCE
BEEPER SOUND
JUMPER JP2
REMOVE
TO RESET
MASTER CODE
TERMINAL
BLOCK
ANTENNA
(HIDDEN)
Figure 1. Component Locations
217350 D IMAGE 4
3
WIRING DIAGRAM
1
2
3
4
5
6
7
8
9
DC OR AC POWER
INHIBIT
COMMON
REQUEST-TO-ENTER
EARTH GROUND
N.O.
COMMON
N.C.
OUTPUT #3
OUTPUT #4
N.O.
COMMON
N.C.
COMMON
10
11
12
13
14
15
AKR-1 TERMINALS
MAIN
RELAY
AUXILIARY
RELAY
1
2
3
4
5
6
7
8
9
DC OR AC POWER
DOOR SENSE
COMMON
REQUEST-TO-ENTER
EARTH GROUND
N.O.
COMMON
N.C.
OUTPUT #3
OUTPUT #4
N.O.
COMMON
N.C.
COMMON
10
11
12
13
14
15
MAIN
RELAY
AUXILIARY
RELAY
AKR-1 TERMINALS
GATE
OPERATOR
INHIBIT
TIMER
OPEN
FIRE
ACCESS
ELECTRIC
DOOR
STRIKE
DOOR
SWITCH
ALARM
CONTACT
OPTIONAL WIRING
REQUIRED WIRING
TO ALARM
SYSTEM
TRANSFORMER
ISOLATED
AUXILIARY
POWER
CAUTION
IF THE UNIT IS AC POWERED,
AND ONE SIDE OF THE POWER TRANSFORMER SECONDARY
IS CONNECTED TO EARTH GROUND, CONNECT THE GROUNDED
SIDE TO THE "-" POWER TERMINAL OF THE UNIT.
POWER
SUPPLY
OPTIONAL WIRING
REQUIRED WIRING
OTHER WIRING
GROUND
STAKE
GROUND
STAKE
NOTES:
1. ALARM SHUNT SET FOR AUXILIARY RELAY
2. TERMINAL 14 SET FOR DOOR SENSE
NOTE:
TERMINAL 14 SET FOR INHIBIT
TYPICAL DOOR INSTALLATION WIRING
TYPICAL GATE INSTALLATION WIRING
217350 D IMAGE 5
4
Pedestal Mounting
The AKR-1 keypad can be mounted on a standard pedestal.
Use four security bolts and locking nuts to secure the
keypads backplate to the pedestal (see Figure 3).
Wall Mounting
The AKR-1 keypad can be mounted directly to a wall or at
surface.
Use the appropriate fasteners to secure the keypads
backplate to the mounting surface.
When mounting the keypad to a concrete wall, use concrete
wedge anchors or molly anchors (see Figure 4).
USE CONCRETE
WEDGE ANCHORS
OR MOLLY ANCHORS
WALL MOUNTING
Figure 4. Wall Mounting Keypad Backplate
Figure 3. Pedestal Mounting Keypad Backplate
PEDESTAL
MOUNT BACKPLATE WITH
SECURITY BOLTS AND LOCKNUTS
217350 D IMAGE 6
5
Gate Control
Refer to Figure 5 for an outline of a typical gate installation.
Route four wires between the gate and the keypad (two for
power, two for control).
Connect the gate operators auxiliary or radio power output
terminals to the keypads POWER input terminals (observe
wiring polarity).
Connect the gate operators OPEN terminals to the keypads
Relay #1 COMMON & N.O. terminals.
NOTE: For operator wiring speci cs, refer to the gate
operators wiring diagram.
If a request-to-enter pushbutton or re access keyswitch is
going to be used, route two wires from the keypad to the
normally open switch. Connect the wires to the normally
open switch and to the keypads REQUEST-TO-ENTER and
COMMON terminals.
If an inhibit switch or timer is going to be used, route two
wires from the keypad to the inhibit switch or timer relay.
Connect the inhibit switch/timer terminals to the keypads
INHIBIT and COMMON terminals.
NOTE: If the INHIBIT input is going to be used, it must be
programmed to select that input type. See the Programming
Options section of this manual
AKR-1
KEYPAD
FIRE
ACCESS
KEYSWITCH
2 WIRES FROM OPERATOR
FOR AKR-1 POWER
GATE
OPERATOR
(BEHI