CHX-SC2

font color=blue>
CHX-SC2
PHOT
OELECTRIC SENSORS
SS-A5
Sensor Checker
CHX-SC2
SU-7/SH
Amplifier-separated
414
Convenient for beam alignment
Since the optical axis of a thru-beam type photoelectric sensor can be checked,
beam alignment is easy.
Suitable for all sensors
This product can be used with infrared,
as well as, red beam type of thru-beam
type photoelectric sensors.
Compact and light weight
Since the sensor checker has a
compact size (W100
H60
D23 mm
W3.937
H2.362
D0.906 in
), it can
be conveniently carried to the place of
use.
(Power supply: 9 V dry cell)
Light and sound indicate optimum position
When the emitter of the thru-beam
type photoelectric sensor and
CHX-SC2 face each other along a
straight line and their optical axes
match, the number of LEDs which light
up in the level indicator, as well as, the
sound tone increases.
Since the sound tone can also be
heard with an earphone, the sensor
checker can be used in a noisy place.
Thru-beam type photoelectric sensor
emitter
Sensor checker
CHX-SC2
LEVEL
POWER
C HX-SC2
LEVEL
POWER
C H X - S C 2
Level indicator
CHX-SC2
Sensor Checker
Extremely useful for
beam alignment of
thru-beam type
photoelectric sensors PHOT
OELECTRIC SENSORS
SS-A5
Sensor Checker
CHX-SC2
SU-7/SH
Amplifier-separated
Infrared beam type or red beam type of thru-beam type photoelectric sensor
9 V (006P dry cell)
Red LED (lights up when the power is ON)
Red LED
5 (light up, successively, according to the incident light intensity)
Audio confirmation with an earphone (frequency increases with light intensity)
Variable adjuster
0 to
40 癈
32 to
104 癋
, Storage: 0 to
40 癈
32 to
104 癋
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure base: ABS, Top cover: ABS
95 g approx.
Applicable sensor
Supply voltage
Power indicator
Light intensity monitor
Sensitivity adjuster
Ambient temperature
Ambient humidity
Material
Weight
CHX-SC2
Model No.
Item
Appearance
Model No.
CHX-SC2
LEVEL
POWER
C HX-SC2
CHX-SC2
415
ORDER GUIDE
SPECIFICATIONS PHOT
OELECTRIC SENSORS
SS-A5
Sensor Checker
CHX-SC2
SU-7/SH
Amplifier-separated
It adjusts the optical sensitivity of CHX-SC2.
Earphones can be connected.
Please separately arrange for earphones having 8 input impedance and
"
3.5 mm
"
0.138 in
plug.
They are used for fitting a strap. Please arrange the
strap separately.
It receives light from the photoelectric sensor.
The sound tone varies with the incident light intensity.
Incident light intensity:
Low
High
Sound tone:
Low
High
Lights up when the power is ON.
The LEDs light up, successively, according to the
incident light intensity from the photoelectric sensor.
Sensitivity adjuster
Earphone jack
Power supply switch
Holes for strap
Receiver section
Buzzer
Power indicator
(Red LED)
Level indicator
(Red LED
5)
1
2
3
4
5
6
7
8
CHX-SC2
416
PRECAUTIONS FOR PROPER USE
This product does not possess control functions
needed for accident prevention or safety maintenance.
Functional description
POWER
LEVEL
POWER
VOL
ON
C H X - S C 2
1
6
7
8
5
2
3
4
Description
Function
Method of use
1
Set the power supply switch ON. At this time, the buzzer
may sound even if light is not incident. However, if the
sensitivity adjuster has been set to min., the buzzer will not
sound.
2
Set the sensitivity adjuster to max.
3
Make the emitter and CHX-SC2 face each other along a
straight line.
4
When light from the emitter is incident, the level indicator
LEDs light up and the sound tone increase. The buzzer starts
sounding when 3 or 4 LEDs of the level indicator light up.
5
By turning the sensitivity adjuster, adjust the sensitivity
such that about 3 LEDs of the level indicator light up.
6
Move CHX-SC2 up, down, right and left to determine the
optimum position where the maximum No. of LEDs of
the level indicator light up and the buzzer sound tone is
the highest.
At this time, if the sensitivity has been set too high,
although a part of the level indicator may light up even in
the beam interrupted condition, it does not indicate any
abnormality.
7
If the sensor checker is being used in a noisy
environment and it is difficult to hear the buzzer, use by
connecting earphones. In this case, the buzzer does not
sound.
Others This product is suitable for use with infrared beam and red
beam type of thru-beam type photoelectric sensors. Use 6F22 (S-006P) type 9 V dry cell (1 pc.) for the power
supply. Since the 9 V dry cell is not supplied as accessory,
please arrange it separately. Make sure that the power supply switch of CHX-SC2 is
OFF when the dry cell is installed or replaced. Switch off the power supply when not using the sensor
checker. Further, if the sensor checker is not used for a
long time, remove the dry cell from the sensor checker
and keep it separately. Take care that the sensor is not directly exposed to
fluorescent light from a rapid-starter lamp or a high
frequency lighting device, as it may affect the beam
alignment.
Emitter
Sensor checker
CHX-SC2
LEVEL
POWER
C HX-SC2
LEVEL
POWER
C H X - S C 2
(
)
n
n
n
n PHOT
OELECTRIC SENSORS
SS-A5
Sensor Checker
CHX-SC2
SU-7/SH
Amplifier-separated
CHX-SC2
417
DIMENSIONS (Unit: mm
in
)
POWER
LEVEL
POWER
VOL
ON
C H X - S C 2
100
3.937
23
0.906
Beam-receiving part
14
0.551
9
0.354
60
2.362