1
Remove the access panel on the back of the stove.
1/4" Nutdriver
2
Insert the wiring harness, with strain relief plate attached, through the hole on the back of the stove. Then attach the
strain relief plate to the back plate with the included screws.
1/4" Nutdriver
Wiring Harness
Strain Relief Plate
NOTE: the wiring harness should be
directed inwards, through an access hole
near the back of the gas control valve.
NOTE: The grounding
wire is attached to the
strain relief plate.
Blower Sweet Dreams
SKU # 99000158
Page 2 of 4
10850 117th Place N.E. Kirkland, WA 98033
Printed February 19, 2004
3
Attach the blower wires and grommets following the directions below.
Insert the bushings
into the 4 grommets.
Slide the 4 grommets onto
the blower mounting plate.
Attach the two wires
labeled "BLOWER" to
the blower.
a
BLOWER
b
c
Blower
Mounting
Plate
4
Attach the blower (with blower plate) following the directions below.
Secure the blower to the stove with the 4 nuts (and washers)
included with the blower.
11/32" Nutdriver
5
Replace the access panel (see step # 1 above).
Blower Sweet Dreams
SKU # 99000158
Page 3 of 4
10850 117th Place N.E. Kirkland, WA 98033
Printed February 19, 2004
6
Remove the control cover and discard the on/off wires following the directions below.
Phillips
Screwdriver
Back of on/off
switch
Gas Control Valve
a
b
Remove the control cover
and place it in front of the
stove.
Remove and discard the wires
leading from the gas control valve
to the on/off switch.
7
Install the rheostat onto the control cover.
1/2"
Wrench
NOTE: this tab fits
into the hole on the
control cover.
Attach the rheostat to the control cover
with the included nut and star washer.
Attach
the knob.
LOW
OFF
BLOWER
c
HI
Blower Sweet Dreams
SKU # 99000158
Page 4 of 4
10850 117th Place N.E. Kirkland, WA 98033
Printed February 19, 2004
8
Attach the wiring harness to the gas control valve, on/off switch, rheostat, and snap disc switch following the directions
below.
Back of
on/off switch
Gas Control Valve
LOW
OFF
HI
BLOWER
Rheostat
Wires
VALVE
RHEOSTAT
SNAP DISC
Snap Disc
9
Position the wiring harness under the burner and re-attach the control cover (see step # 6 above). Make sure the
wiring harness does not contact the burner or blower.
10 Turn on the appliance and check operation (the blower will not turn on until the stove is at full temperature 15
minutes on high).