Installation Instructions

ck>Yahoo! is not affiliated with the authors of this page or responsible for its content.
Installation Instructions Systems Inc., 284 Broadway, Huntington Station, NY 11746 631.421.1230 FAX 631.421.1274
Model 2035 Series II Deluxe Automation Instructions
The Kelmar Deluxe Custom Automation System is comprised of a Basic System with OPTIONAL features so that it
can be suited to all applications.
System Configurations:
1. Basic System
2. 060 Minute Show Start Timer Option
3. Built in SYNC Operation Option
ANY OR ALL OPTIONS CAN BE ADDED TO THE BASIC SYSTEM.
*
BASIS SYSTEM FEATURES CONTROL OF:
* Projector Drive Motor
* Xenon Lamphouse
* Changeover Dowser
* Exciter Lamp
* Dolby Audio System (or similar)
* House Light Dimmer
* Stage Light Dimmer
* Screen Curtain
* NonSync (dry and 120 VAC Output)
* Lights up early for House Light Dimmer
* Built in Alarm
* Full Remote Control Capability
* Curtain Slide Projector
**
MANUAL CONTROL SWITCHES PROVIDED FOR:
* Projector Drive Motor
* Xenon Lamp
* Exciter Lamp
* Changeover Dowser
* House Light Dimmer
* Stage Light Dimmer
* Curtain Projector
* Lens/Masking Switch
BASIC SYSTEM SEQUENCE OF OPERATIONS
A. SHOW START: (Start Button or Clock Option)
1. Changeover CLOSE
2. Motor & Lamp ON
3. Non-Sync OFF
4. House Lights [MID] or DOWN
5. Stage Lights OFF
6. Changeover OPEN, Exciter ON
7. Dolby MONO
B. CROSS FRAME CUE:
1. House Light Dimmer DOWN
2. Lens/Masking SCOPE or FLAT Pre-Select
3. Audio System MONO or STEREO Pre-select Page 2
SEQUENCE OF OPERATIONS (continued)
C. INBOARD CUE:
1. House Light Dimmer [MID] or UP
D. OUTBOARD CUE:
1. House Light Dimmer [UP]
2. Stage Light Dimmer UP
3. Changeover CLOSE, Exciter OFF
4. Motor & Lamp OFF (Selectable, as C.O. Closes or as Film Runs thru)
5. Non-Sync ON
6. Dolby Non-Sync
****OPTIONAL SHOW START CLOCK:
0-60
Minute Clock Timer can be Preset to Start the show after selected interval.
*****OPTIONAL SYNC OPERATION PACKAGE:
Provides SYNC [interlok operation with 2 Automation Systems, Additional Module installs in main cabinet, plugs
into chassis, has control button on panel.
For Multiple Auditoriums a Sync Selector Unit is available to SYNC 4 Automations in any of 4 different combina-
tions. The Sync Selector Units may be ganged together for 8, 12, or 16 Auditoriums, permitting any 4 SYNC operations
at once.
I DENOTES DIMMER POSITION WITH KELMAR H Series DIMMER
CONTACT:
Kelmar Systems Inc.
284 Broadway
Huntington Station, New York 11746
Phone (631) 4211230 Page 3
The Kelmar Deluxe Automation is contained in one steel enclosure with dimensions as follows:
WIDTH 16 1/4
HEIGHT -17 5/8
DEPTH -6 1/2
The Deluxe Automation Cabinet should be mounted on the FRONT WALL of the Projection Room, Below the Observation
Port, with the TOP of the cabinet 3-6 A.F.F. (Above Finished Floor).
Refer to Riser Diagram (Drawing No. 1309), for the wires required between the Deluxe Automation and the various
devices to be controlled. Verify the devices to be controlled, for example: is there a Curtain and a Masking motor?
Verify if the Automations will be INTERLOKED or not, if they are to be interloked, verify how many and where the SYNC
SELECTOR MODULE(S) should be located. Refer to Instructions included with the SYNC MODULE and the SYNC
SELECTOR MODULE for Installation Details.
Verify what kind and type of REMOTE control system will be
installed. The Kelmar Deluxe Automation can be used with the
Kelmar Deluxe Automation Remote Control or with the Kelmar Remote
Status System.
The Kelmar Deluxe Automation Remote Control provides Remote operation of the: START and STOP buttons, Mode,
ALARM light and buzzer, Run Light, Fault Light, Stop light.
The Kelmar Remote Status System is available in 4, 6, and 8 Auditorium Modules, with or without an Alarm latch, and
provides PROJ. RUN, FAULT, and ALARM LIGHT and BUZZER for each Automation, and a RESET button for the latch
module.
Since the Kelmar Deluxe Automation can be used with a variety of Projectors, Audio Systems, Xenon Lamps, Dimmers
etc. Consult the instructions furnished with the device for terminations. The Kelmar Dimmers include an interface
schedule for the automation terminations.
ALL CONTROL CIRCUITS (except the 120 VAC Non-Sync term. 19,20) ARE DRY SWITCH CONTROL CIRCUITS.
For assistance with terminations CONTACT:
Kelmar Systems Inc.
284 Broadway
Huntington Station, New York 11746
Phone (631) 421-1230 Page 4
KELMAR DELUXE AUTOMATION- TERMINATION SCHEDULE
Term. No. Term. No.
1.
OUTBOARD CUE ROLLER
26.
120 VAC INPUT AUTOMATION FEED *
2.
INBOARD CUE ROLLER
27.
120 VAC NEUTRAL AUTO. FEED
3.
FAILSAFE MICRO SWITCH
28.
GROUND (SWITCHING COMMON)
4.
GROUND (SWITCHING COM.)
29.
MOTOR FEED
5.
REMOTE START
30.
MOTOR
6.
REMOTE C.O. CLOSE [I/L]
31.
XENON LAMP
7.
REMOTE STOP BUTTON
32.
XENON LAMP
8.
REMOTE PROJ. RUN PL(12v)
33.
C.O. FEED
9.
REMOTE PROJ. STOP PL(12v)
34.
C.O. OPEN
10.
REMOTE FAULT PL(12v)
35.
C.O. CLOSE
11.
REMOTE ALARM OUT 12 VAC
36.
C.O. CLOSE [N.C.] (CINEMECCANICA)
12.
HOLD FOR INTERLOK
37.
EXCITER INPUT (EXCITER SUPPLY +)
13.
12 VAC OUTPUT
38.
EXCITER LAMP (+)
14.
GROUND (SWITCHING COM.)
39.
HOUSE DIMMER CONTROL FEED
(STRAP,REMOVE FOR I/L)
15.
C.O. CLOSE (LOGIC)
40.
HOUSE DIMMER SHOW START OUT
16.
LENS/MASKING FEED
41.
HOUSE DIMMER FEATURE CUE (CROSS)
17.
LENS/MASKING FLAT
42.
HOUSE DIMMER INBOARD CUE
18.
LENS/MASKING SCOPE
43.
HOUSE DIMMER SHOW END
19.
LINE
44.
STAGE DIMMER FEED
120 VAC NON-SYNC
20.
NEUTRAL
45.
STAGE DIMMER UP
21.
AUDIO SWITCHING FEED
46.
STAGE DIMMER DOWN
22.
AUDIO SWITCHING MONO
47.
SCREEN PROJECTOR FEED
23.
AUDIO SWITCHING STEREO
48.
SCREEN PROJECTOR OUTPUT
24.
AUDIO SWITCHING NON-SYNC 49.
NON-SYNC DRY INPUT
25.
50. NON-SYNC DRY OUTPUT
*
FOR SYNC (INTERLOK) ALL INTERLOKED AUTOMATIONS MUST BE POWERED FROM THE SAME PHASE Page 5
**
KELMAR DELUXE AUTOMATION-TERMINATION SCHEDULE Page 2 **
51.
CROSS FRAME CUE ROLLER
52.
START LOGIC OUTPUT
(STRAP, REMOVE ONLY FOR AUD. DELUXE MODULE)
53.
START CIRCUIT INPUT
54.
CURTAIN CONTROL FEED
55.
CURTAIN CONTROL OPEN
56.
CURTAIN CONTROL CLOSE
57.
THIRD DIMMER FEED (OPTIONAL)
58.
THIRD DIMMER LOWER (OPTIONAL)
59.
THIRD DIMMER RAISE (OPTIONAL)
60.
61.
62. Page 6
AUTOMATION CONTROL SWITCHES:
SW
FUNCTION
S1
AUDIO FEATURE PRE-SELECT (CROSS CUE) Pre-set to MONO or STEREO for Feature Format. activated
by CROSS CUE, or S4.
F1
MAIN FUSE
S2
POWER ON-OFF SWITCH Turns Power to Automation Unit ON or OFF.
PL-1
Feature Mode L.E.D. Lights after CROSS CUE has been detected or Manually advanced by S4.
S3
LENS/MASKING FEATURE PRE- SELECT (CROSS CUE) Pre-set to SCOPE or FLAT for FEATURE Format
activated by CROSS CUE, or S4.
PB-1
AUTOMATION START BUTTON, press to START show with Automation. Button lights to indicate that
PROJ. is running. PLEASE NOTE: Automation WILL NOT START WITH FAILSAFE DOWN.
PL-2
TIMER CYCLE LIGHT- Indicates that cam Timer is in CYCLE. Will light after start button is pressed or
OUTBOARD CUE has been detected.
PB-2
AUTOMATION STOP/RESET BUTTON, press to STOP show while running Automation. Top light
indicates that PROJ. is NOT Running, Bottom Light indicates that the FAILSAFE is DOWN (FAULT). The
Automation WILL NOT START if the Fault Light is ON. The STOP Button also functions as a RESET for
the Interval Show Start Timer (OPTIONAL) After the Timer has been started with S6, it can be turned OFF
by pressing STOP.
S4MANUAL CUE SWITCH-Used to MANUALLY provide an INBOARD or CROSS CUE. INBOARD position
provides House Dimmer MID Output, CROSS position provides FEATURE preselects of 51 and S3. Use to
RE-START the Show after a Film Break, or special showings.
PB-3
ALARM CANCEL PUSHBUTTON -used to turn off the ALARM Buzzer.
S5
SHOW END MODE used to select the Function of the OUTBOARD CUE to either NORMAL, the projector
shuts off after the Tail runs through, or AUTO-STOP (Mid-Platter Intermission) the projector shuts off as the
C.O. Closes.
OPTIONAL START TIMER SWITCH:
S6
INTERVAL TIMER MODE * [CLOCK OPTION] Used to START the Interval TIMER start Clock. 3 position
toggle switch. NORMAL Position center. To START Interval Timer, Press to RIGHT. For a PRE-SET MID-
PLATTER INTERMISSION (Clock Starts Automatically) set S6 to INTER. START (LEFT) and SHOW END
MODE SWITCH S5 to AUTO-STOP. TIMER will START as Projector shuts OFF. IF MID-PLATTER Inter. is
used, Reset S5 or S6 prior to end of show or timer will Re-start.
NOTE: S8 Will NOT CLOSE C.O. if a NORMALLY CLOSED, energized while OPEN C.O. is used (term
#36). A Normally Closed C.O. will function properly with Automation. Page 7
AUTOMATION CONTROL SWITCHES:
SW
FUNCTION
S7
MANUAL MOTOR, Turns Projector Motor ON or OFF Manually. Leave in AUTO position for Automation
Operation.
S8
MANUAL C.O., Opens or Closes CHANGEOVER Manually, PLEASE NOTE: S8 willNOT CLOSE C.O. if a
NORMALLY CLOSED, energizedwhile OPEN C.O. is used (term #36). A Normallly Closed C.O. will
function properly with Automation.
S9
MANUAL LENS/MASKING SWITCH, Manually controls LENS Changer or MASKING connected to
terminals 16, 17, 18.
S10
MANUAL LAMP SWITCH, Turns Xenon Lamp ON or OFF Manually. Leave in AUTO position for
Automation Operation.
S11
MANUAL HOUSE DIMMER, Controls DIMMER manually, Connected to Terminals 39, 41, 43.
S12
SYNC SELECTOR* [SYNC OPTION] used to select SYNC operation.
Refer to instructions with SYNC OPTION.
S13
MANUAL EXCITER SWITCH, used to turn EXCITER LAMP On or OFF Manually.
Leave in AUTO position for Automation Operat