Touch Time

g=10 cellspacing=0 width=100%>Yahoo! is not affiliated with the authors of this page or responsible for its content.
Touch Time SH5370.1
P L U M B I N G F I X T U R E S
T E C H N I C A L
D A T A
P.O. Box 309, Menomonee Falls, WI 53052-0309
Phone 1-800-BRADLEY FAX 262-251-5817
http://www.bradleycorp.com
Document No. 5370
This information is subject to change without formal notice.
10-11-2005 (2 Pages Total)
Touch Time Electronic Control
Reliable Metering of Water for Showers
Electronically-Controlled Metering Cycle
Safe Low Voltage
Easy to Install/Electronics Built into Push-Button
ADA Compliant
Operation
Touch Time equipped fixtures control water flow at each
station through the use of solid state, digital circuitry. When
the push-button* is pressed, a signal is sent through its built-in
circuitry controlling the opening and closing of solenoid
valves. The system operates directly on 24 volt power or 110
volt with the use of an optional transformer. Timing is
electronically controlled at 60 or 180 seconds.
Standard Equipment
Specifications
Push-button with integral circuitry
The push-button with self-contained integral circuitry is a
digital solid state "brain" that electronically controls the
timing of one solenoid valve. Individual and group fixtures
are prewired and preassembled.
Solenoid
24V, 50/60Hz, 1/2 amp, 1/4"NPT. The electrically
activated solenoid valve provides reliable performance since
there are few moving parts and its operation is unaffected
by most chemicals and minerals often present in municipal
water supplies. The solenoid valve does not require
adjustment for timing.
Wiring/Electrical
Preassembled fixtures prewired complete. 24V power supply
required. Conformity to local codes is the responsibility of
the installer.
*Note: Activation of the push-button takes place only
when it is released, thereby preventing "hold
open" activation.
Optional Equipment
Transformer
Optional transformers available. Sizing of transformer
depends on number of stations served (approximately
1/2 amp draw per station).
Timing
Touch Time is factory set and available in 60 or 180 second
timing. P L U M B I N G F I X T U R E S
T E C H N I C A L
D A T A
SH5370.2
Touch Time Electronic Control
Sample Specifications
Valving shall be Bradley Touch Time Electronic Control
System. Each station is controlled through the use of solid
state digital circuitry.
Valve
Hot, cold, or tempered water to be supplied through a
slow closing anti-hammer solenoid valve, timed from an
electronic circuit board, activated by a low voltage, non-hold
open push-button.
Circuit Board
The electronic circuit board shall be capable of controlling one
station and shall be sealed within the push-button assembly. It
shall provide a 60-second metering cycle.
Wiring
All internal electronic components of preassembled fixtures
shall be prewired by Bradley by the use of quick disconnect
connectors. 24V power required for each push-button/circuit
board assembly. All external wiring to the fixture is by others.
Conformity to local codes is the responsibility of the installer.
**Note: Requires plumbing chase or remote access.
Touch Time (1C-TT) * *
2-7/8"
(73)
16"
(406.4)
5-7/8"
(149.2)
3-1/2"
max
(89)
4-1/4"
(108)
1/2" IPS
(by others)
2-1/4"
(57.2)
Solenoid
valve
Escutcheon
(2) Screws
(anchors
by others)
P.O. Box 309, Menomonee Falls, WI 53052-0309
Phone 1-800-BRADLEY FAX 262-251-5817
http://www.bradleycorp.com
Document No. 5370
This information is subject to change without formal notice.
10-11-2005 (2 Pages Total)