PAM250
>
« back to results for ""
Below is a cache of http://www.tamuracorp.com/clientuploads/pdfs/engineeringdocs/PAM250.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive.
Yahoo! is not affiliated with the authors of this page or responsible for its content.
PAM250
Input Voltage:
85-132/180-264 VAC, 47-63 Hz, 1 phase
Input Current:
<6A RMS @ 115 VAC @ full load
<3A RMS @ 230 VAC @ full load
Inrush Current:
<35A, pk @ 265 VAC @ cold start
<75A, pk @ 132 VAC @ cold start
Harmonic Distortion:
Meets EN61000-3-2 for Class A
EMI Filtering:
Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Input Protection:
Internal AC line fuse; 250 VAC, 8A
Surge Withstand:
Meets EN61000-4-5 Level 3
Output Power:
250W with 25CFM air; 130W Convection
Line Regulation:
± 0.3%
Load Regulation:
± 0.5%
PARD:
<1% or 50mV;
20MHz bandwidth
Hold-up Time:
16 ms @ full load (120 VAC)
Output Polarity:
Output is floating
Minimum Load:
0% of rated load
Transient Response:
3% for 25% load change @ 1A/µs;
50% duty cycle 50/60 Hz
Output Rise Time:
<100 ms (10% to 90%)
Current Limit:
105-130% of rated current; Hiccup
Remote Sense:
Compensates for up to 250mV of total cable
drop
Remote On/Off:
Optional
Leakage Current:
< 300 A
Thermal Shutdown
Standard
DC OK:
Standard; Open Collector
Turn-on Delay:
<1 second after application of AC Input
Stability:
<0.1% for 8 hours
after 1/2-hour warm up
Isolation:
>20 M @ 100 VDC between output
terminals and chassis ground
AC Power Fail:
TTL
LOW
logic 0 at least 2 ms before
output drops 5%; Open collector
Overvoltage Protect:
Factory set, 125% ±5%,
cycle AC to reset
Reverse Voltage:
Output has reverse voltage protection;
Reverse current limited to 100% of output
rating
Efficiency:
Up to 85%
MTBF:
MIL-STD-HDBK 217E
>200,000 hours @ 25°C
Highly Accelerated Life Testing
Electrical Specifications
Continuous
Voltage
Voltages
Current
Codes
(Volts)
(Amps)
-4
12.0
21
-5
15.0
17
-6
24.0
10.5
-7
28.0
9.0
-8
36.0
7.2
-9
48.0
5.5
* Consult factory for other voltages and OEM quantities.
Note: Standard models are shown
bold
Available Voltage Outputs
*
PAM250
Model
250 Watts
max
output power
Power Factor Correction
Single Output
Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
Medical Grade
Certifications
PART # STRUCTURE:
MODEL - VOLTAGE CODE - OPTION CODES
(See sheet 2)
-
V1
-
PAM250 - X - ABC....
Example: Part Number PAM250-6-OR= 250W Power Factor Corrected, 24V @ 10.5A with an OR-ring Diode and Remote On/Off.
CLICK HERE TO SEE THE PAM250 CODE TABLE AND AVAILABLE OPTIONS.
Physical Specifications
Dimensions: (HxWxL)
1.5" x 4.0" x 7"
Operating Temp:
0 to 70°C; rated power to 50°C
derate linearly to 50% at 70°C.
Relative Humidity:
5% to 90%, non-condensing
Storage:
-50 to 85°C/20-90% RH
Altitude:
10,000' operating;
40,000' storage
Options (code)
12V@0.5A Aux./Fan Drive (A)
Droop Current Share ±10% (B)
Fan Assembly (C)
DC OK Invert (E)
PF Invert (F)
Field-Configurable (G)
Single Wire Current Share ±5% (I) Square Current Limit (J)
Molex Connector (K)
Metric Mounting (M)
OR-ing Diode (O)
Remote On/Off (R)
Remote On/Off Invert (S)
Model
Certifications
NRTL* * * Recognition to UL60601-1
CSA C22.2 No. 601-01
BAUART Certification to EN60601-1
CB Test Report in Accordance with IEC60601-1
CE Decleration to Low Voltage Directive 72/23/EEC
* * * Nationaly Recognized Test Laboratory
Compliance
EN61000-4-5 Level 3
EN61000-4-2 Level 2
EN61000-3-2 for Class A
EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3
EN61000-4-11
CISPR 11 and 22 FCC Part 15 Class B (conducted)
FM 32227
© Copyright 2006 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
TAMURA CORPORATION OF AMERICA
43352 Business Park Drive, Temecula, CA 92590-6624
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com
PAM250