INSTR-002 MTE ONLY Rel 050503 Matrix Filter Series A 480V ƒ

r>Yahoo! is not affiliated with the authors of this page or responsible for its content.
INSTR-002 MTE ONLY Rel 050503 Matrix Filter Series A 480V ƒ © 2000 MTE Corporation

PART NO. INSTR - 002
REL. 060607
M T E C o r p o r a t i o n
MATRIX FILTER
SERIES A
480 Volts 60 Hz

USER MANUAL

PDF created with pdfFactory trial version
www.pdffactory.com PDF created with pdfFactory trial version
www.pdffactory.com IMPORTANT USER INFORMATION


NOTICE



The MTE Corporation Matrix Filter is designed for harmonic mitigation of six
pulse inverter drives supplying variable torque loads in a wide variety of
applications. The suitability of this filter for a specific application must
therefore be determined by the customer. In no event will MTE Corporation
assume responsibility or liability for any direct or consequential damages
resulting from the use or application of this filter. Nor will MTE Corporation
assume patent liability with respect to the use of information, circuits or
equipment described in this instruction manual.



PDF created with pdfFactory trial version
www.pdffactory.com PDF created with pdfFactory trial version
www.pdffactory.com TABLE OF CONTENTS




1. Safety .......................................................................................................... 1

2. Introduction ................................................................................................. 3

3. Model Number Codes .................................................................................. 4

4. Specifications .............................................................................................. 5

Ratings ....................................................................................................... 5

Service Conditions ..................................................................................... 5

Performance ............................................................................................... 6

Altitude Derating Curve ............................................................................ 10

5. Installation Instructions ............................................................................. 11

Filter Installation ....................................................................................... 11

Power Wiring Connection ......................................................................... 11


Ground and Ground Fault Protection......................................................... 12

Input and Output Terminal Specifications ................................................. 12


Outline
Drawings and Mounting Dimensions ............................................ 13


Interconnection Diagrams .......................................................................... 23

6. Filter Description ....................................................................................... 26

7. Start Up .................................................................................................. 28

8. Troubleshooting ......................................................................................... 29

8. Addendum A .............................................................................................. 33
PDF created with pdfFactory trial version
www.pdffactory.com
1
1. IMPORTANT SAFETY INFORMATION


WARNING

ONLY A QUALIFIED ELECTRICIAN CAN CARRY OUT THE ELECTRICAL
INSTALLATION OF THIS FILTER



WARNING

High voltage is used in the operation of this filter. Use Extreme caution to avoid
contact with high voltage when operating, installing or repairing this filter. INJURY
OR DEATH MAY RESULT IF SAFETY PRECAUTIONS ARE NOT OBSERVED.

After removing power, allow at least five minutes to elapse and verify that the
capacitors have discharged to a safe level before contacting internal components.
Connect a DC voltmeter across the capacitor terminals 1, 2 and 3 on terminal block
1TB. Start with the meter on the highest scale and progressively switch to a lower
scale as the indicated voltage falls below the maximum value of the scale used.


WARNING

The opening of the branch circuit protective device may be an indication that a fault current
has been interrupted. To reduce the risk of fire or electrical shock, current-carrying parts and
other components of the filter should be examined and replaced if damaged.


WARNING

An upstream disconnect/protection device must be used as required by the National
Electrical Code (NEC).


WARNING

Even if the upstream disconnect/protection device is open, the drive down stream of the filter
may feed back high voltage to the filter. The drive safety instructions must be followed.
INJURY OR DEATH MAY RESULT IF THE DRIVE SAFETY PRECAUTIONS ARE
NOT OBSERVED.




PDF created with pdfFactory trial version
www.pdffactory.com
2
WARNING

The filter must be grounded with a grounding conductor connected to all grounding terminals.



WARNING

Only spare parts obtained from MTE Corporation or an authorized MTE distributor can be
used.
PDF created with pdfFactory trial version
www.pdffactory.com
3
2. INTRODUCTION

This manual was specifically developed to
assist in the installation, interconnection
and operation of the MTE Corporation
Matrix Filter.

This manual is intended for use by
personnel experienced in the operation and
maintenance of electronic drives. Because
of the high voltages required by the filter
and drive and the potential dangers
presented by rotating machinery, it is
essential that all personnel involved in the
operation and maintenance of this filter
know and practice the necessary safety
precautions for this type of equipment.
Personnel should read and understand the
instructions contained in this manual before
installing, operating or servicing the filter
and the drive to which the filter is
connected.

Upon Receipt of this Filter:


The MTE Matrix Filter has been subjected
to demanding factory tests before shipment.
Carefully inspect the shipping container for
damage that may have
occurred in transit. Then unpack the filter
and carefully inspect for any signs of
damage. Save the shipping container for
future transport of the filter.

In the event of damage, please contact
and file a claim with the freight carrier
involved immediately.

If the equipment is not going to be put into
service upon receipt, cover and store the
filter in a clean, dry location. After storage,
ensure that the equipment is dry and that
no condensation has accumulated on the
internal components of the filter before
applying power.


Repair/Exchange Procedure


MTE Corporation requires a Returned
Material Authorization Number before it can
accept any filters that qualify for return or
repair. If problems or questions arise during
installation, setup, or operation of the filter,
please call us for assistance at:

Phone: 262-253-8200

FAX: 262-253-8222





















PDF created with pdfFactory trial version
www.pdffactory.com 4
3. MODEL NUMBER CODES


Standard series A model number codes are of the form MA-BCDEFG-XY with the
number coded as outlined below
.

Character
Description
Code



M
Always M for Matrix Filter




A
Designates number of input phases
1 Single phase


3 Three phase



B
Characters B through E designate the
Example: 0075 is a 75 Hp filter
C
Horsepower rating of the filter using

D
four digits with leading zeros

E





F
Indicates mechanical configuration
N Nema1


R Reactive components only


M Magnetic components only


P Panel mounted


W Weather proof


D Dust tight


H Hose down



G
Designates input voltage and frequency A 208-240 v / 60Hz


B 240 v / 50 Hz


C 380-415 v / 50 Hz


D 480 v / 60 Hz


E 600 v / 60 Hz


F 690 v / 50 Hz


G 690 v / 60 Hz


H 120 v / 60 Hz


J


K


L 277 v / 60Hz



XY
Designates filter guaranteed harmonic
12 is 12% THID

current performance
8 is 8% THID




PDF created with pdfFactory trial version
www.pdffactory.com 5
4. SPECIFICATIONS
Ratings


480 VAC Three Phase Input Filter Ratings
(Panel Mounted)*
THID Rating
12%
8%
HP
Maximum
Input
Amps
RMS
Maximum
Output
Amps
RMS
Efficiency

(Typical)
(%)
Power
Dissipation
@ Rated
HP
(Typical)
(Watts)
Weight
(lbs)
Efficiency

(Typical)
(%)
Power
Dissipation
@ Rated HP
(Typical)
(Watts)
Weight
(lbs)
3
6
6
97
47
27
98
40
37
5
9
10
98
66
35
98
63
42
7.5
13
14
98
98
35
98
98
42
10
16
18
98
114
45
98
108
60
15
24
27
98
166
50
98
170
75
20
31
34
98
204
85
98
212
100
25
39
43