INSTALLATION AND OPERATION MANUAL

/tr> Yahoo! is not affiliated with the authors of this page or responsible for its content.
INSTALLATION AND OPERATION MANUAL ZONE CONTROL SYSTEM
INSTALLATION AND OPERATION MANUAL SlimZone Premier
i
TABLE OF CONTENTS
1. INTRODUCTION .............................................................................................................................1
1.1 IMPORTANT NOTE....................................................................................................................................1
1.2 FEATURES.................................................................................................................................................1
1.3 SAFETY INSTRUCTIONS..........................................................................................................................2
2. APPLICATION AND DESIGN CONSIDERATIONS ........................................................................2
3. COMPONENT REQUIREMENTS ...................................................................................................3
3.1 BASIC SYSTEM ........................................................................................................................3
3.2 EXPANDER MODULE ...............................................................................................................3
3.3 ENVIRONMENTAL MODULE ....................................................................................................4
3.4 SIZING TRANSFORMERS ........................................................................................................4
3.5 SIZING DAMPERS ....................................................................................................................4
3.6 TYPICAL SYSTEM DIAGRAM...................................................................................................4
4. SYSTEM INSTALLATION................................................................................................................6
4.1 SLIMZONE PREMIER CONTROL MODULE (SZP) ..................................................................................6
4.1.1 REMOVAL AND INSTALLATION OF THE DOOR .........................................................................6
4.1.2 INSTALLATION OF THE BACKPLATE ..........................................................................................6
4.2 THERMOSTAT INSTALLATION: DSL-520P...............................................................................................7
4.3 DAMPERS..................................................................................................................................................7
4.4 WIRING INFORMATION ..........................................................................................................................10
4.5 CURRENT LIMITED OUTPUT TERMINALS ...........................................................................................10
4.6 SLIMZONE ENVIRONMENTAL MODULE (SZEM)..................................................................................11
5. SYSTEM OPTIONS AND OPERATION ........................................................................................12
5.1 INTERACTION BETWEEN MODULES ...................................................................................................12
5.1.1 SZP CONTROL MODULE............................................................................................................12
5.1.2 DSL-520P ZONE THERMOSTAT.................................................................................................13
5.1.3 SZEM ENVIRONMENTAL MODULE ...........................................................................................14
5.2 SYSTEM PROGRAMMING......................................................................................................................14
5.2.1 PROGRAMMING FEATURES .....................................................................................................14
5.2.2 SCHEDULES................................................................................................................................14
5.2.3 FACTORY DEFAULTS .................................................................................................................15
5.3 USER OPTIONS ......................................................................................................................................15
5.4 HVAC OPTIONS.......................................................................................................................................15
5.5 CONTROL METHODS .............................................................................................................................16
5.5.1
TIMESHARE.................................................................................................................................16
5.5.2 DIFFERENTIAL ............................................................................................................................16
5.6 SEQUENCE OF OPERATION .................................................................................................................17
5.6.1 TIMESHARE MODE.....................................................................................................................17
5.6.2 DIFFERENTIAL MODE ................................................................................................................18
5.7 USER INTERFACE ..................................................................................................................................18
5.7.1 LCD SYMBOL DESCRIPTION.....................................................................................................18
5.8 FLOW DIAGRAM .....................................................................................................................................19 ii
SlimZone Premier
6. START UP AND TEST...................................................................................................................22
TROUBLESHOOTING GUIDE ...............................................................................................................26
GLOSSARY ............................................................................................................................................27
APPENDIX A: LIST OF FIGURES ........................................................................................................28
APPENDIX B: LIST OF TABLES ..........................................................................................................28
ZONE SCHEDULE .................................................................................................................................29
ZONE DIAGRAM....................................................................................................................................30
WARRANTY ...........................................................................................................................................31 SlimZone Premier
1
1.
INTRODUCTION
The SlimZone Premier (SZP) is a commercial/residential HVAC (Heating/Ventilation/Air
Conditioning) zone control system which allows control of up to nineteen (19) zones with a
single HVAC system. Each zone is controlled by its own zone thermostat and motorized
damper. The control module monitors the zone thermostats, sets the HVAC system in the
appropriate mode of operation, and energizes the number of stages of heating or cooling
accordingly.
The basic system consists of the main SlimZone Premier control module (SZP-3) which may
control up to three (3) zones. The modular nature of this system allows the expansion of the
number of controlled zones by simply adding SlimZone Expander modules (SZEX) which add
two (2) zones to the system per module. Up to eight (8) expander modules may be connected
to the control module, allowing a total of nineteen (19) zones.
Only DSL-520P communicating zone thermostats may be used with the SlimZone Premier
Control module. Each zone to be controlled requires a zone thermostat.
The user interface to the SlimZone Premier consists of a four (4) button keypad and a four (4)
line by twenty (20) character LCD display, through which all system information may be viewed
or modified.
1.1
IMPORTANT NOTE
IT IS IMPORTANT THAT YOU READ AND UNDERSTAND THIS MANUAL SUPPLIED WITH
THE SLIMZONE PREMIER, AS WELL AS THE HVAC EQUIPMENT MANUFACTURERS
INFORMATION, BEFORE BEGINNING INSTALLATION OF THE SYSTEM.
1.2
FEATURES Ultra slim styled cabinet (8-7/8" (22.5cm)W x 9-1/2" (24cm)H x 1-3/4" (4.5cm)D) Two (2) modes of operation: timesharing or differential Four (4) lines by twenty (20) characters backlit LCD display User friendly interface which allows access to features such as:
- panel setup
- system programming (temperatures, schedules, 2 or 4 events per day)
- 12 or 24 hour clock
- temperature display in 癋 or 癈
- equipment test LED (light emitting diode) status indicators on all system functions Solid state control module with current limited relay outputs Controls heat pumps, cooling units and gas, oil or electric furnace units Number of controlled zones expandable to nineteen (19) in increments of two (2) zones by
ordering the SlimZone Expander module (SZEX) Controls up to four (4) stages of heating and three (3) stages of cooling in heat/cool mode Controls u