FDC3302

is a standard feature. In addition, remote
control and status monitoring via a network port is available as an option. The FDC3302 is unique in the industry - no other low-cost system
offers this combination of capabilities and performance in a single product.
Output Signal Quality
The FDC3302 features low-signal distortion and added phase noise along with
high isolation between output channels. Power supply voltages are post-regu-
lated and all output buffers are individually regulated, ensuring very low output
spurious noise levels.
Autoswitching
The FDC3302 can be configured for single or dual input operation. If two inputs
are available then the FDC3302 will monitor the input signals. If an input is
removed or the amplitude is greatly reduced it will automatically switch to the
other input. This feature ensures that your critical signals are always present.
Alarm Input
The FDC3302 is compatible with the alarm output signal from the Meridian
Precision GPS TimeBase and the Tycho Frequency Reference. If one of these units is sourcing the FDC3302 and its alarm output goes active,
then the FDC3302 will automatically switch to the backup source. Since this alarm input may be cascaded to multiple FDC3302 units simply,
using BNC T-adapters and coaxial cable, multiple FDC3302 units can be bank switched.
Status Indicators
Front panel LEDs provide you at-a-glance status of the distribution chassis. The FDC3302 provides LED indicators for the power supply(ies), the
two inputs, all output signals and a summary alarm indicator. The summary alarm is also available as an open-collector output on a rear-panel
BNC.
Control and Status Monitoring
The FDC3302 can be configured and monitored by means of an RS-232 serial port. Both switch status and output status can be monitored in
this way. For remote control and monitoring, a network port is available as an optional upgrade.
Options
The FDC3302 Frequency Distribution Chassis can be configured for one input or two inputs with autoswitch. Two inputs is the factory default.
An additional option is the capability of having dual redundant, AC or DC power supplies. The two power supplies can be any combination
of AC/AC, AC/DC, or DC/DC. A network port that can be used for remote control and status monitoring is also available with a full suite of
network protocols.
Two-Year Warranty
The FDC3302 Frequency Distribution Chassis is backed by a full two-year warranty against defects in material and workmanship.
Money-Back Guarantee
If your FDC3302 does not meet your time and frequency distribution needs for any reason, simply return it within 60 days for a full refund.
Refer to www.endruntechnologies.com/guarantee.htm for more details.


FEATURES
.
Single Input or
Autoswitching Between Dual Inputs
.
10-Channel, Broadband
(100 kHz to 30 MHz)
Sine Wave Distribution
.
Very Low Added Phase Noise
.
Very High Port-to-Port Isolation
.
Very Low Distortion
.
RS-232 Port
for Control and Monitoring
.
Dual-Redundant AC or DC Power
Supply Options
.
Ethernet Port Option for Remote
Control and Monitoring
Time and Frequency Distribution
Santa Rosa, CA, USA
TEL 1-877-749-3878
FAX 707-573-8619
www.endruntechnologies.com
Santa Rosa, CA
TEL 1-877-749-3878
FAX 707-573-8619
www.endruntechnologies.com
"Smarter Timing Solutions"
FDC3302
High-Performance Frequency Distribution Chassis
Specifications
INPUTS (A and B):
-- Frequency Range: 100 kHz to 30 MHz.
-- Impedance: 50
, SWR <1.1.
-- Amplitude: +13 dBm Full Performance, 0 dBm ±2 dBm minimum, +15 dBm maximum.
-- A Input to B Input Isolation: < -105 dB, full frequency range.
-- Protection: Protected to 24V peak-to-peak.
-- Connectors: Rear-panel female BNCs.
OUTPUTS (1 through 10):
-- Impedance: 50
,
SWR <1.8 @ 100 kHz.


SWR < 1.2 @ 1 MHz.


SWR < 1.3 @ 10 MHz


SWR < 1.8 @ 30 MHz.
-- Unity Gain: 0 dB, +/- 1dB.
-- Harmonics: < -40 dBc @ 13 dBm and 100 kHz <= F <= 20 MHz,

< -35 dBc @ 13 dBm and F > 20 MHz,

< -30 dBc @ 15 dBm.
-- Spurious: < -110 dBc.
-- Port-to-Port Isolation:
< -100 dB @ 100 kHz to 10 MHz


< -90 dB @ > 15 MHz.
-- SSB Phase Noise @ 10 MHz and +13 dBm output level:

At 1 Hz
< -135 dBc/Hz.

At 10 Hz
< -145 dBc/Hz.

At 100 Hz < -155 dBc/Hz.

At 1 kHz
< -163 dBc/Hz.

At 10 kHz < -163 dBc/Hz.
-- Protection: Outputs may be shorted to ground with no damage.
-- Connectors: Rear-panel female BNCs.
EXTERNAL ALARM INPUTS (A and B):
-- Normal State: TTL low.
-- Alarm State: TTL high or high Z (internal 10K pull-up).
-- Connectors: Rear-panel female BNCs.
ALARM OUTPUT:
-- All fault indicators are summed together providing this common alarm output.
-- Open Collector, 40VDC Max, 100 mA Max Saturation Current.
-- High impedance when fault condition exists.
-- Connector: Rear-panel female BNC.
MAINTENANCE PORT:
-- RS-232 serial I/O on DB9M jack for local terminal access. Used for control and status information.
-- User-Selectable Port Settings: 9600 to 57600 baud; 7 or 8 data bits;
odd, even or no parity; 1 or 2 stop bits.
-- Factory Default Settings are: 19200,8,n,1.
SYSTEM STATUS INDICATORS:
-- Input LEDs: Green when a signal is detected on the input channel and red when the signal is
absent. The FDC3302 can be configured for two input signals with autoswitch or for only one
input signal.
-- Output LEDs: Green when the output signal is OK and red when a short is detected.
-- Power LEDs: Green when the power supply is OK, and red when a fault condition exists.
-- Alarm LED: Red when any fault condition exists. All fault indicators are summed together to
provide this one common fault.
POWER:
-- 90-264 VAC, 47-63 Hz, 0.5A Max. @ 120 VAC.
-- 3-Pin IEC 320 on rear panel, 2-meter cord included.
SIZE:
-- Chassis: 1.75H x 17W x 10.75D.
-- Weight: < 5 pounds.
ENVIRONMENTAL:
-- Temperature: -0° to +50°C.
-- Humidity: 0 to 95%, non-condensing.
-- Storage Temperature: -40 to +85 C.
COMPLIANCE:
-- CE, FCC.
OPTIONS:
-- Can be configured for one or two inputs. Factory default is two inputs with autoswitch.
-- -48, +12, +24/28, +125 VDC input.
-- Dual-redundant AC or DC power supplies. Combinations can be AC/AC, AC/DC, or DC/DC.
-- Network Port: Ethernet 10Base-T or 100Base-TX; RJ-45 connector;
Protocols include: TCP/IP, SSH, DHCP, FTP, Telnet and SNMP MIB-II.
080207