Tellabs 5500 Digital Cross-Connect System - Consolidated Core Switch (CCS)
Core Switch (SCS) systems.
The Tellabs 5500 DCS 4608 CCS switch matrix resides in a single
shelf, with two shelves required for redundancy. A fully redundant
Tellabs 5500 DCS 4608 switch matrix, along with Administrative
Complex (AC) shelves, fits into just two bays compared to the
nine bays required for a SCS 3072 configuration. In addition, Tellabs
continues the commitment to support existing equipment in
customers networks by providing the capability to expand any
existing Tellabs 5500 SCS (256, 1024, 1536 and 3072 core sizes)
to over 4K core size with as little as one additional bay of equipment.
This capability offers significant savings in both floor space and power
consumption compared to current standard density core configurations.
Features & Benefits
4608 STS-1 (240G) total capacity in 2 shelves
100% Non-blocking matrix
Full STS-1 and VT1.5 grooming capability
Native support of DS1 interfaces no adjuncts
Supports STS-1e, DS1, DS3, OC-3, OC-12 and OC-48
interfaces
Full transmux capability
Centralized management
Consolidates 12 bays of equipment into 2 shelves
Designed for high reliability
1+1 redundant switch shelves
Physical separation of switch complexes
Full suite of Tellabs 5500 DCS features
ASIST, bridge & roll, performance monitoring, test access,
trace route, etc.
Designed for easy expansion of port capacity
Tellabs 5500 DCS reliability stats exceed 99.99975%
Figure 1. Tellabs
5500 Digital Cross-connect System
Consolidated Core Switch (CCS) Rack
Figure 2. Tellabs
5500 Digital Cross-connect System
Consolidated Core Switch (CCS) Shelf
DATA SHEET
TELLABS
5500 DIGITAL CROSS-CONNECT SYSTEM CONSOLIDATED CORE SWITCH (CCS)
2
TR-TSY-000476, Operations Technology Generic Requirements
(OTGR): Network Maintenance: Access and Testing, Issue 3, 6/90,
Bellcore
TR-TSY-000827, Operations Technology Generic Requirements
(OTGR): Generic Operations Interfaces Non-OSI Communications
Architecture, Issue 1, 11/88, Bellcore
TR-NWT-001244, Clocks for the Synchronized Network: Common
Generic Criteria, Issue 1, Bellcore, June 1993
TR-NWT-000233, Wideband and Broadband Digital Cross-Connect
Systems Generic Criteria, Issue 3, Bellcore, November 1993
TR-NWT-000332, Reliability Prediction Procedure, Issue 5, Bellcore,
December 1995
TR-NWT-000170, Digital Cross-Connect System Generic
Requirements and Objectives, Issue 2, January, 1993
TR-TSY-000012, MML Requirements, Issue 1, Bell Communications
Research, January 1985
Technical Advisories (TA)
TA-TSY-000200, Specification of System Maintenance Messages at
the OS/NE Interface, Issue 4, Bellcore, September 1988
TA-NWT-001080, Bellcore Standard Operating Environment
Security Requirements, Issue 2, 6/91, Bellcore
Generic Requirements (GR)
GR-253-CORE, Synchronous Optical Network (SONET) Transport
Systems: Common Generic Criteria, (A Module of TSGR, FR-440;
FR-SONET-17; and FD-29) Issue 4, December 2005
GR-820-CORE, Generic Digital Transmission Surveillance, Issue 1,
November 1994
GR-1244-CORE, Clocks for the Synchronized Network: Common
Generic Criteria, Issue 2, December 2000
GR-1400-CORE, SONET Dual-Fed Unidirectional Path Switched Ring
(UPSR) Equipment Generic Criteria, Issue 1, March 1994
GR-63-CORE, Network Equipment Building System (NEBS) Generic
Requirements: Physical Protection, Issue 1, October 1995
GR-2914-CORE, Human Factors Requirements for Equipment to
Improve Network Integrity, Issue 1, December 1995
GR-199-CORE, Operations Technology Generic Requirements
(OTGR): Operations Application Messages Memory Administration
Messages, Issue 3, February 1999
GR-2924-CORE, Generic Requirements for National MCUP
Committee CSCANS, Issue 1, April 1996
GR-833-CORE, Operations Technology Generic Requirements
(OTGR): Network Maintenance Network Element Transport and
Surveillance Messages, Issue 4, Bellcore, June 2000
GR-499-CORE, Set: Transport System Generic Requirements
(TSGR): Common Requirements, Issue 3, Bellcore, September 2004
GR-815-CORE: Generic Requirements for Network Element/Network
System (NE/NS) Security, Issue 1, Bellcore, November 1997
General Specifications
Dimensions
Height: 22.75 in (57.8 cm)
Width: 21.5 in (54.6 cm)
Depth: 15.0 in (38.1 cm)
Mounts in 23-in rack
Power fully equipped (per shelf)*
< 860 Watts at -48V DC
< 17.8A at -48V DC
< 20.4A at -42V DC
Breaker size: 50 amp
Normal operating temperature range
41F to 104F (5C to 40C)
Meets normal operating temperature range requirements
specified in Telcordia GR-63-CORE (NEBS)
Short-term operating temperature range
23F to 122F (-5C to 50C) for no more than 96 consecutive
hours, and a total of no more than 15 days per year
Operating relative humidity range
5%85% (non-condensing)
Operating short-term relative humidity
5% to 90%, but not to exceed 0.024 pounds of water per pound
of dry air for no more than 96 consecutive hours, and a total of
no more than 15 days per year
Operating altitude range
From 196 feet (60 m) below mean sea level up to 13,000 feet
(4,000 m) above mean sea level manufacturer will provide
special requirements for installations above 1800 m
* For current 4608 STS-1 configuration. Shelf is designed for up to 6144 STS-1
to allow for future expansion.
Standards Compliance
Technical References (TR)
TR-TSY-000191, Alarm Indication Signal Requirements and
Objectives, Bellcore, Issue 1, May 1986
TR-TSY-000454, Supplier Documentation for Network Elements,
Issue 1, 7/88
TR-TSY-000474, Operations Technology Generic Requirements
(OTGR): Network Maintenance: Network Element, Issue 3, 11/89
TR-NWT-00796, Reliability and Quality Generic Requirements
(RQGR), 1991, Bellcore
TR-NWT-000815, Network Element (NE) Memory Administration
Network Element and Network System Security, Issue 2, 12/92,
Bellcore
DATA SHEET
TELLABS
5500 DIGITAL CROSS-CONNECT SYSTEM CONSOLIDATED CORE SWITCH (CCS)
3
GR-831-CORE: Operations Application Messages Language for
Operations Application Messages, Issue 1, Bellcore, November
1996
GR-474-CORE: Network Maintenance: Alarm and Control for
Network Elements, Issue 1, Bellcore, December 1997
GR-1089-CORE: Electromagnetic Compatibility and Electrical Safety
Generic Criteria for Network Telecommunications Equipment,
Issue 2, December 1997, Revision 1, February 1999
GR-1339-CORE, Generic Reliability Requirements for Digital Cross-
Connect Systems, Issue 1, March 1997, Bellcore
GR-1250-CORE, Generic Requirements for Synchronous Optical
Network (SONET) File Transfer, Issue 1, June 1995, Bellcore
GR-472-CORE, Network Element Configuration Management, Issue
2, November 1996
GR-78-CORE, General Requirements for the Physical Design and
Manufacturing of Telecommunications Products and Equipment,
Issue 1, Bellcore, September 1997
GR-2996-CORE, Generic Requirements for SONET Digital Cross-
Connect Systems, Issue 1, Bellcore, January 1999
GR-1230, SONET Bidirectional Line-Switched-Ring Equipment
Generic Criteria, Issue 4, December 1998
Special Report (SR)
SR-332, Reliability Prediction Procedure, Issue 1, Bellcore, May
2001
SR-3528, NEBS Criteria Levels, Issue 1, Bellcore, November 1995
ANSI Documentation
ANSI T1.101-1994, Revision of ANSIT1.101-1987, American
National Standard for Telecommunications, Synchronization
Interfaces Standard
ANSI T1.102-1993, American National Standard for
Telecommunications, Digital Hierarchy Electrical Interfaces
ANSI T1.231-1993, American National Standard for
Telecommunications, Digital Hierarchy Layer 1 In-Service Digital
Transmission Performance Monitoring
ANSI T1.105.03-1994, American National Standard for
Telecommunications Synchronous Optical Network (SONET)
Jitter at Network Interfaces
ANSI T1.105.03a-1995, American National Standard for
Telecommunications Synchronous Optical Network (SONET)
Jitter at Network Interfaces DS1 Supplement
ANSI T1.105.03b-1997, American National Standard for
Telecommunications - Synchronous Optical Network (SONET)
Jitter at Network Interfaces DS3 Wander Supplement
ANSI T1.105-1991, American National Standard for
Telecommunications, Digital Hierarchy Optical Interface Rates
and Formats Specifications (SONET)
ANSI T1.403-1989, American National Standard for
Telecommunications, Carrier-to-Customer Installation DS1
Metallic Interface
ANSI T1.107-1995, American National Standard for
Telecommunications, Digital Hierarchy Formats Specifications
ANSI T1.107a-1990, American National Standard for
Telecommunications, Digital Hierarchy Supplement to Formats
Specifications (DS3 format applications)
ANSI T1.403-1995, American National Standard for
Telecommunications, Network-to-Customer Installation DS1
Metallic Interface
ANSI T1.403.02-1999, American National Standard for
Telecommunications, Network and Customer Installation Interfaces
DS1 Robbed-Bit Signaling State Definitions
ANSI/IEEE Std. 802.2-1989, Information Processing Systems
Local Area Networks Part 2: Logical Link Control
ANSI/IEEE Std. 802.3-1990, Information Processing Systems
Local Area Networks Part 3: Carrier Sense Multiple Access with
Collision Detection (CSMA/CD) Access Method and Physical Layer
specification
ANSI/IEEE 802.3i-1990 (Supplement to ISO/IEC 8802-3 1990/
ANSIIEEE Std. 802.3-1990) System Configurations for Multiple-seg-
ment 10 MB/s Baseband Networks (Section 13) and Baseband
Medium Attachment Unit (MAU) and Baseband Medium Type
10BASE-T (Section 14)
ANSI T1.204-1993, American National Standard for
Telecommunications Operations, Administration, Maintenance
and Provisioning (OAM&P) Lower-Layer Protocols