8011 HL High Voltage Power Supply for Virtual AC Intelligent Static ...
the enclosure with 14 bolts.
The power supply circuit board assembly is installed on the mounting plate.
There are twelve tool-secured terminals for input and control wires. There
are two high voltage outputs for connecting the high voltage cables from
the neutralizing bar. The power ON LED is connected between two of the
input terminals. The LED is intended to warn maintenance personnel when
the power is on.
The power supply circuit board assembly on the mounting plate is shipped
inside the explosion-proof enclosure, but it is not secured to the enclosure.
This provides the unobstructed space for pulling the wiring through the
conduits into the enclosure. Once the wires are inside the enclosure, the
mounting plate with circuit board assembly is secured to the enclosure.
1
SPECIFICATION SHEET
MODEL 8011HL
The Virtual AC Intelligent Static Neutralizer (U.S. Patent 5,930,105;
6,088,211; 6,130,815; 6,259,591; others pending) employs a novel ionization
technology for superior static neutralizing performance. The system
simultaneously monitors several performance and diagnostic
parameters. The system displays the critical information and alerts the
operator when it is time to clean the bar or if there is a problem.
The Virtual AC HL-Type Intelligent Static Neutralizers are approved by
FM Approvals for use in Class I, Division 1 or 2, Group D hazardous
locations in the US and Canada.
There are two configurations of the Virtual AC Neutralizer for hazardous
locations: with a visual operator interface and with a computer
interface.
The computer interface and Fieldbus versions of the Virtual AC
Intelligent Static Neutralizer for Hazardous Locations consist of a high-
efficiency 8001HL static neutralizing bar, solid-state high voltage power
supply with a built-in monitoring circuit, (model 8011RM in Canada and
models 8011RM or 8011HL in the US), 8003 computer interface or 8003-
Fieldbus module and 24-volt transformer.
In the Neutralizer with standard interface, the 8003 computer interface
module is substituted with the 8005 control module with visual indicators
and controls.
The 8001HL neutralizing bars, 8011HL power supply and the HL
Termination Box are designed for use inside the hazardous location. The
8011RM power supply, control module and 24-volt transformer must be
installed outside the hazardous area.
The HL Termination Box simplifies installation and removal of
neutralizing bars, and high voltage wiring inside conduits.
NEUTR
ALIZING CURR
ENT
0
8004
Control Module
8
000 Series Intelligent
Static Neutralizer
F
OR USE WITH V.AC8011 HVPS MODELS ONLYU.S. Patent 5,930,105
1
00%
0
%
ION
OUTPUT
SYSTEM
DIAGNOSTICS
B
AR ON
B
AR OFF
C
LEAN BAR
MALFUNCTION
NEUTRALIZATION
OK
NON-HAZARDOUS AREA
HAZARDOUS AREA
8001HL
Neutralizing
Bar
8011HL
High Voltage
Power Supply
Control
Module
24-volt
Transformer
Conduit
Control
Cords
HL
Termination
box
basic
neutralizer
Virtual AC Neutralizer for hazardous locations with 8011HL HVPS.
Intelligent Static Neutralizers
for Hazardous Locations
Enclosure
Cover
Conduit
Seal fittings
Mounting
flanges
Bolts for
sealing the
cover
Power supply
board
Cover hinges
8011HL high voltage power supply.
Version 5.0
2
SPECIFICATION SHEET
M O D E L 8 0 1 1 H L H I G H V O L T A G E P O W E R S U P P L Y ( H V P S )
SPECIFICATIONS
Input voltage
24 volts ac nominal
Output voltage
9 kV peak
Output power
10 watts
Output current
1.5 mA, max (short-circuit protected)
Maximum load (bar length)
132 inches with total up to 45 ft. of
high voltage wires
High voltage connections
Terminals with 6-32 threaded holes
Input & control connections
Screw terminals
Enclosure
Explosion-proof watertight
Dimensions
12 1/2L x 10 1/2W x 6 1/2H
Weight
22 lbs
Mounting
Wall-mount
Operating temperature
32F to 105F
Insulation
Pollution degree 1, installation
category I, according to ISA-S82.01
Interface compatibility
8003 computer interface module
and 8005 or 8005M control module
Certifications
FM approved for Class 1, Div. 1 & 2,
Group D
24-volt ac transformers
The following 24-volt ac transformers are available for use with the Virtual AC Neutralizers. See transformer specification sheet for details.
- Single output 24 volt-ac wall transformer, Ion Systems p/n 14-1316
TOP VIEW
SIDE VIEW
FRONT VIEW
10
1
/
2
"
12
1
/
2
"
4
1
/
2
"
2
3
/
4
"
6
3
/
4
"
1
/
2
" NPT
9
1
/
8
"
3
1
/
2
"
HVPS footprint and mounting dimensions.
18"
18"
10'
18"
18"
8001HL
bar
Conduit
Seal
Seal
Seal
Conduit
8011HL
HVPS
HL Termination Box
(optional)
Seal
Wiring and sealing diagram for HL Neutralizer installation with
the HL termination Box.
NON-HAZARDOUS AREA
HAZARDOUS AREA
MKS, Ion Industrial
1000 Old County Circle, #116
Windsor Locks, CT 06096
Phone: 860-292-6847
Fax: 860-292-6807
www.mksinst.com/ion-industrial
Email: industrial@ion.com
MKS, Ion Industrial Europe
Marie-Curie-Strasse 8
D-79539 Loerrach, Germany
Tel. ++ 49 (0) 7621 - 5500 355
Fax ++ 49 (0) 7621 - 5500 360
Email: indeuro@ion.com
MKS, Ion Systems
Alameda, California
USA