IMPORTANT!
Yahoo! is not affiliated with the authors of this page or responsible for its content.
IMPORTANT!
Standard Dimming Transceiver Switch
& Dedicated Remote
Model
US11-30/USR
Simply Automated, Incorporated
5825 Avenida Encinas, Suite 101, Carlsbad, CA 92008 USA
Technical Support: www.simply-automated.com or 800-630-9234
452-0001-0101 Rev. A Revised: December 9, 2005
TROUBLESHOOTING
PROBLEM PROBABLE
CAUSE SOLUTION
Master switch is wired properly
but has no power.
(LED indicator is OFF)
Air gap power disconnect may be disengaged (pulled out).
Push light pipe (indicator) back into position flush with faceplate
assembly housing.
3-way remote switch actuator may be binding, causing the
switch to be stuck ON or OFF.
Loosen mounting screws on remote switch and/or wallplate to
relieve pressure on housing.
Master switch actuator doesnt
turn load ON and/or OFF.
(LED indicator is ON)
Actuator faceplate may not be seated properly on the
switch body.
Exercise actuator several times to ensure proper seating and
operation.
Mounting screws may be too tight or j-box may be
deformed, causing the switch body to warp.
Loosen mounting screws to relieve pressure on the switch
housing.
Rocker sticks or doesnt actuate
properly when pressed.
Actuator springs may have backed out of their correct
location during shipping.
Reseat the springs: place the faceplate face-up on a flat surface,
then press down on both sides of each rocker at the same time.
Switch is overloaded.
Reduce the power load by removing bulbs from the circuit.
Switch runs hot when dimming
the load.
Switch is dimming a load that is not rated for use with
incandescent dimmers.
Reconfigure the switch for ON/OFF operation with no dimming
(using UPStart, for example).
UPB FACTORY DEFAULT SETTINGS
To restore the following default settings, place the US11-30 in SETUP mode and
tap any actuator exactly 10 times. The indicator will continuously blink RED.
Tap the actuator twice again to exit SETUP mode.
Network Name
Network 1
Room Name
New Room Name
Device Name
New SA US1/US2
Unit ID
22
Network ID
255
Network Password
1234
Transmit Link
1
Receive Links
1 (ON) and 2(OFF)
POWER DISCONNECTION
To physically disconnect power to the connected lamp fixture, depress the top of
the rocker switch, grab the underside of the clear plastic indicator tab with your
fingernail, pull the tab out about 0.05, then push the tab down to lock it in place.
The indicator will extinguish to show that power is now disconnected. To
reconnect power, simply push the tab up and it will snap back into its normal
position.
Simply Automated, Incorporated
5825 Avenida Encinas, Suite 101, Carlsbad, CA 92008 USA
Technical Support: www.simply-automated.com or 800-630-9234
452-0001-0101 Rev. A Revised: December 9, 2005
UPB Standard Dimming Transceiver Switch
Model US11-30
Universal Dedicated Remote
Model USR
Provides ON/OFF and dimming control for:
Incandescent lighting
Magnetic low-voltage lighting
Halogen lighting
IMPORTANT!
Read This Before Installing!
This incandescent dimmer
cannot be used to dim
FLUORESCENT, ELECTRONIC LOW-VOLTAGE or
METAL HALIDE lighting
, unless specifically allowed
by the lighting manufacturer.
Please see
instructions
to configure this product for ON/OFF
operation with these types of lighting.
DO NOT WIRE HOT!
Permanent damage may result.
Improper installation voids the warranty.
Model US11-30 shown with actuator faceplate
FUNCTION
The SimplyBrilliant UPB Dimming Transceiver Switch, model US11-30, allows
remote control of permanently-installed new or existing lighting fixtures, lamps
and other electrical devices. Each unit has one rocker switch that directly
controls a load up to 900W (see Table 1). Incandescent lamps can be turned ON
or OFF, and can also be dimmed and brightened. The US11-30 can be
configured to turn other types of non-dimmable loads ON and OFF. The switch
may also act as a transmitter that can communicate with other UPB devices,
either individually or collectively for lighting scenes.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions should always be
followed, including the following:
1.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.
REMOVE YELLOW INSTALL WITH CARE LABEL BEFORE
INSTALLING.
3.
Installation should be performed by a qualified electrician.
4.
Keep away from water. If product comes into contact with water or other
liquid, disconnect immediately.
5.
Never use products that have been dropped or damaged.
6.
Do not use this product outdoors.
7.
Do not use this product for other than its intended use.
8.
Do not connect multiple lamps that, when combined, exceed the maximum
load rating of the product, de-rated for multi-gang boxes.
9.
Do not install in areas that can exceed 120°F (e.g., in an attic).
10. To avoid the risk of overheating and possible damage to other equipment,
do not use this product to control a receptacle.
11. Do not cover the product with any material when in use.
12. SAVE
THESE
INSTRUCTIONS.
INSTALLATION
The SimplyBrilliant UPB Dimming Transceiver Switch (US11-30) is designed to
be installed in a junction box that is wired to a readily accessible over-current
protection device in the building wiring per NEC and CEC electrical codes.
CAUTION: The default switch configuration operates as a dimmer for
incandescent lamps. It will also dim magnetic low-voltage and halogen
lamps. To control fluorescent, electronic low-voltage or metal halide lamps,
or motor-operated appliances, transformer-supplied appliances or fans, the
switch must be reconfigured for ON/OFF operation (no dimming) prior to use.
Refer to the section on Configuration.
CAUTION: DO NOT WIRE THIS DEVICE WITH POWER
CONNECTED. Injury or permanent damage to the device may
result. Improper installation voids the product warranty.
1.
Locate the existing wall switch for the lighting to be controlled. Note that
the lamp rating (or the combined rating of all connected lamps) must not
exceed what is shown in the de-rating table below.
Number of Load Dimmers in J-box
Table 1:
Power per Dimmer
1
2
3+
1
600W
--
--
2
800W
500W
--
Number of J-box
Gangs
3+
900W
700W
500W
2.
Disconnect power at the circuit breaker.
3.
Remove the existing wall switch hardware. Disconnect wires to the switch.
4.
Remove the yellow INSTALL WITH CARE label, if present.
5.
Using a wire nut, connect all white (Neutral) wires together.
6.
Using a wire nut, connect the brown (load output) wire of the US11-30 to
the black wire of the device to be controlled.
7.
IF THIS IS TO BE A 3- OR MORE-WAY INSTALLATION, use a wire nut to
connect the brown/white wire to the traveler wire that extends to the slave
switch. If there is a second slave and a second traveler, use a wire nut to
connect the red/white traveler to the wire that extends to the second slave
switch location. Refer to the wiring diagrams on pages 3 and 4.
8.
Using a wire nut, connect the black (Line) wire of the switch to the black
(Line) power wire.
9.
Mount the switch inside the J-box using captive screws. DO NOT OVER
TIGHTEN THE SCREWS.
10. Reconnect power at the circuit breaker.
Standard Dimming Transceiver Switch
& Dedicated Remote
Model
US11-30/USR
Simply Automated, Incorporated
5825 Avenida Encinas, Suite 101, Carlsbad, CA 92008 USA
Technical Support: www.simply-automated.com or 800-630-9234
452-0001-0101 Rev. A Revised: December 9, 2005
REMOTE SWITCH INSTALLATION
To install a USR Dedicated Remote switch for 3- or more-way control:
1.
Locate the remote switch connected to the master wall switch.
2.
Disconnect power at the circuit breaker.
3.
Remove the existing wall switch hardware. Disconnect the wires to the
existing 3-way switch.
4.
Using a wire nut, connect the white (Neutral) wire of the USR to the white
(Neutral) power wire.
5.
Using a wire nut, connect the brown/white wire of the USR to the traveler
wire that extends to the master switch.
6.
For dual-remote configuration, connect the red/white wire to the traveler
wire that extends to the second master switch.
7.
OPTIONAL: Using a wire nut, connect the brown wire (black on some
models) of the USR to the switched load wire or to the black (Line) power
wire. This only powers the LED indicator. If connected to the switched load
wire, the LED will illuminate when the load is ON. If connected to line
power, the LED will always be ON. If capped with a wirenut, the LED will
always be OFF
8.
Cap off any unused wires to prevent shorting.
9.
Mount the switch inside the J-box using existing screws. DO NOT OVER
TIGHTEN SCREWS.
10. Reconnect power at the circuit breaker.
CONFIGURATION
Configuration requires UPB setup/configuration software and a model UMC
Computer Interface Module. Download the latest version of UPStart
Configuration software from the Simply Automated website.
The US11-30 default settings assume a ZS11 (single rocker) faceplate. The
device will not operate correctly with any other model of faceplate. The
US11-30 must be properly configured using UPStart, this is done by selecting the
U