ST100 Shuttle BoxUser's Manual
12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrols.com
ST100 SHUTTLE BOX
VTR CONTROLLER
USER MANUAL
1
ST100 Shuttle Box
TABLE OF CONTENTS
1. 2. REVISION HISTORY ........................................................................................................... 3 DESCRIPTION ...................................................................................................................... 4 a. b. c. 3. 4. STANDARD FUNCTIONS TIME CODE DISPLAY REAL-TIME STATUS INDICATORS: ACTIVE ON 4 4 4
INSTALLATION ................................................................................................................... 4 OPERATION.......................................................................................................................... 5 a. b. c. d. e. SHUTTLE BOX OPERATION LOOP-THRU CONNECTOR RECORD MODE RECORD SELECTOR SWITCHES TIME CODE DISPLAY 5 5 5 6 6
5.
SPECIFICATIONS ................................................................................................................ 7 FRONT PANEL REAR PANEL CONNECTORS RS422 SERIAL CONNECTOR GPI (KEYPAD) INTERFACE CONNECTOR SHUTTLE WHEEL SPEEDS 7 7 7 8 9
6. 7. 8. 9.
RACKMOUNT FRONT AND REAR VIEW....................................................................... 9 TABLE TOP, TOP VIEW.................................................................................................... 10 TABLE TOP, REAR VIEW................................................................................................. 11 DNF CONTROLS LIMITED WARRANTY ..................................................................... 12
Manual Version ........................................ 2.31 102506 Document No. .............. ST100_Shuttle_Box_User_Manual
2
ST100 Shuttle Box
1.
REVISION HISTORY
031204 Rev. 2.2 Company header information revised. Added DNF Controls Limited Warranty Reformatted. Revised GPI (KEYPAD) INTERFACE CONNECTOR Added Timecode select function.
073004 Rev. 2.3 102506 Rev. 2.31
3
ST100 Shuttle Box
2.
DESCRIPTION
a. STANDARD FUNCTIONS
RECORD PLAY STOP REWIND FAST FORWARD JOG/SHUTTLE MODE SELECT JOG & SHUTTLE WHEEL: Active ONLY from STOP/STILL or JOG/SHUTTLE modes.
b.
TIME CODE DISPLAY
Display timecode or CTL Tape Timer per the mode selector switch on the front panel of the VTR. The Time Mode can be selected manually by pressing the [SHIFT] + [JOG] keys, each press will step to the next Time Mode: CTL Tape Time, Timecode, VITC.
c.
REAL-TIME STATUS INDICATORS: ACTIVE ON
RECORD PLAY STOP/STILL REWIND/REVERSE FAST FORWARD/FORWARD JOG MODE SELECTED
3.
INSTALLATION
a. Plug one end of a 9-conductor, RS422 serial cable into the 9-pin connector on the rear of the ST100. Plug the other end of the cable into the 9-pin REMOTE connector on the VTR. Plug the 9-pin D-female connector on the POWER SUPPLY into the male 9-pin connector on the rear of the ST100. Plug the AC connector into a wall outlet, 90 VAC - 265 VAC, 50-60 Hz. c. d. Select REMOTE operation on the VTR's front panel. Set the RECORD SELECTOR SWITCHES, located on the rear panel of the ST100, to the desired record mode per the "RECORD SELECTOR CHART." Connect the second Controller to the 9-pin female connector labeled LOOP-THRU, on the back of the ST100, using a 9-pin cable wired as described below, "LOOPTHRU CONNNECTOR."
b.
e.
Installation is completed. NOTE: For AMPEX 1-inch and D2 VTRs, set VTR ID to 0001.
4
ST100 Shuttle Box
4.
OPERATION
Select the desired transport function by pressing the appropriate switch on the front of the ST100. The Real-Time Status Indicators will light to indicate the VTRs current tape transport mode. For example: Pressing PLAY will put the VTR into the PLAY mode. The PLAY Status Indicator will light when the VTR is in PLAY mode.
Loss of serial communication with the VTR is indicated by ALL status LEDs turned ON. Selecting LOCAL control on the VTR's front panel will turn OFF all status LEDs.
a.
SHUTTLE BOX OPERATION
The Shuttle Box automatically determines whether the ST100 or second controller gets control of the VTR using the following rules: 1) Normally, the LOOP-THRU is turned on, allowing the second controller to control the VTR. When any function switch is pressed on the ST100 or the Wheel is moved, the LOOP-THRU is turned off, disabling the second controller. The ST100 now has control of the VTR. After the selected function is executed, and after a 2.5 second delay, the LOOP-THRU is again turned on, allowing the second controller to control the VTR. When the LOOP-THRU is turned on, the ST100 monitors communications between the VTR and second controller. The VTR's status response is read by the ST100 and the status indicators are updated to reflect the current state of the VTR.
2)
3)
b.
LOOP-THRU CONNECTOR
RS422 Serial Interface 9-Pin D-Type, Female
Pin # 1 2 3 4 5 6 7 8 9 Frame Ground Transmit A Receive B Receive Common Spare Transmit Common Transmit B Receive A Frame Ground
c.
RECORD MODE
Four (4) Record modes are available: Crash Record (Full Record), Assemble Record, Insert Record and Record Lockout. Press only the [RECORD] switch to activate the selected Record mode. The Record Status Indicator will light when the VTR is in RECORD mode. NOTE: The VTR will not go into Record mode if "Record Inhibit" is enabled on the VTR or tape cassette.
5
ST100 Shuttle Box
d.
RECORD SELECTOR SWITCHES
Mode Record Lockout Assemble Record Crash Record Insert Record S1 OFF ON OFF ON S2 OFF OFF ON VID S3 OFF OFF OFF AUD1 S4 OFF OFF OFF AUD2 S5 OFF OFF OFF AUD3 S6 OFF OFF OFF AUD4 Active On
NOTE: AUD3 & AUD4 should be ON ONLY for VTRs that support 4 channels of audio, i.e.: D1, D2 and D3 type VTRs.
e.
TIME CODE DISPLAY
Display timecode or CTL Tape Timer per the mode selector switch on the front panel of the VTR. The Time Mode can be selected manually by pressing the [SHIFT] + [JOG] keys, each press will step to the next Time Mode: CTL Tape Time, Timecode, VITC.
6
ST100 Shuttle Box
5.
SPECIFICATIONS
FRONT PANEL
6 Status LEDs 1 Power LED 3 Direction LEDs Switches DIP Switches Display Jog/Shuttle Wheel Size Indicates direction of Jog Shuttle Record, Play, Stop, Rewind, Fast Forward, Jog, Shift,Reset RECORD MODE: Lockout, Crash, Insert, Assemble 2-line LCD, back lit with adjustable contrast With Mechanical Detents at 1X Play Speed 19" x 5" x 1-3/4" (Rackmount) 7" x 5" x 1-1/2" (Table Top) 2 lbs. Record, Play, Stop, Rewind, FFwd, Jog
Weight
REAR PANEL CONNECTORS
RS422 Serial Out Power 9-Pin D-type connector, female (DB9-F) 5 volt D.C., 500 ma. 90-265 VAC, 0/60 Hz converter supplied (Rack Mount or table top) 15-pin D-type connector, female (DB15F) Switch Input: SPST contact closure, momentary Status Output: Open collector, sink 50mA.
GPI
RS422 SERIAL CONNECTOR
9-Pin D-Type, Female (DB9-F)
Pin # 1 2 3 4 5 6 7 8 9 Function Frame Ground Receive A Transmit B Transmit Common Spare Receive Common Receive B Transmit A Frame Ground
7
ST100 Shuttle Box
GPI (KEYPAD) INTERFACE CONNECTOR
15-Pin D-Type, Female (DB15-F)
Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Function +9VDC=Table Top; +5VDC=Rack mount Switch #7, Shift Mode Select Led #1 drive, Record Status Indicator Led #2 drive, Play Status Indicator Led #3 drive, Stop Status Indicator Led #4 drive, Rewind Status Indicator Led #5 drive, Fast Forward Status Indicator Led #6 drive, Jog Mode Indicator Command Common Switch #1, Record Command Switch #2, Play Command Switch #3, Stop Command Switch #4, Rewind Command Switch #5, Fast Forward Command Switch #6, Jog Mode Select Note Power for Status Indicators Active Low OC Output Active Low OC Output Active Low OC Output Active Low OC Output Active Low OC Output Active Low OC Output Active Low OC Output Active Low Active Low Active Low Active Low Active Low Active Low (+5 Pull Up) (+5 Pull Up) (+5 Pull Up) (+5 Pull Up) (+5 Pull Up) (+5 Pull Up)
NOTE: There are no internal current limiting resistors for the open collector, status indicator drives. A 620 ohm resistor in series with the D.C. power supply is recommended for LEDs. Limit lamp current to 50 ma.
Connection Diagram
8
ST100 Shuttle Box
SHUTTLE WHEEL SPEEDS
NOTE- ( ) represents Shuttle
Reverse speeds STILL
10 x Play, Max. Speed ( -.50 x Play)
.50 x Play ( -10 x Play ) ( Max Speed )
2.0 x Play ( -2 x Play)
6.
RACKMOUNT FRONT AND REAR VIEW
9
ST100 Shuttle Box
7.
TABLE TOP, TOP VIEW
10
ST100 Shuttle Box
8.
TABLE TOP, REAR VIEW
11
ST100 Shuttle Box
9.
DNF CONTROLS LIMITED WARRANTY
DNF Controls warrants its product to be free from defects in material and workmanship for a period of one (1) year from the date of sale to the original purchaser from DNF Controls. In order to enforce the rights under this warranty, the customer must first contact DNF's Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair. If DNF's Customer Support Department cannot fix the problem, the customer will be issued a Returned Merchandise Authorization number (RMA). The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer's shipping document. The merchandise is to be shipped to: DNF Controls 12843 Foothill Blvd., Suite D Sylmar, CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted, or in a charge for the required repair. DNF Controls, at its option, will repair or replace the defective unit. DNF Controls will return the unit prepaid to the customer. The method of shipment is at the discretion of DNF Controls, principally UPS Ground for shipments within the United States of America. Shipments to international customers will be sent via air. Should a customer require the product to be returned in a more expeditious manner, the return shipment will be billed to their freight account. This warranty will be considered null and void if accident, misuse, abuse, improper line voltage, fire, water, lightning or other acts of God damaged the product. All repair parts are to be supplied by DNF Controls, either directly or through its authorized dealer network. Similarly, any repair work not performed by either DNF Controls or its authorized dealer may void the warranty. After the warranty period has expired, DNF Controls offers repair services at prices listed in the DNF Controls Price List. DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non-repairable. DNF Controls shall not be liable for direct, indirect, incidental, consequential or other types of damage resulting from the use of the product. ###
12
ST100 Shuttle Box