Standby Power Rating 45 kW 60 Hz CA
ue>
« back to results for ""
Below is a cache of http://www.guardiangenerators.com/publicPDFs/0174970SBY.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive.
Yahoo! is not affiliated with the authors of this page or responsible for its content.
Standby Power Rating 45 kW 60 Hz CA
All input connections in one single area
High coolant temperature shutdown
Low oil pressure shutdown
Low coolant level automatic shutdown
Overspeed automatic shutdown
Crank
timer
Exercise
timer
Oil drain extension
Cool flow radiator
Closed coolant recovery system
UV/Ozone
resistant
hoses
Watertight state of the art electrical connectors
Mainline circuit breaker
Radiator drain extension
Battery charge alternator
2 Amp static battery charger
Battery rack and battery cables
Fan and belt guards
Isochronous
governor
Flex fuel line pigtail
STANDARD EQUIPMENT
Innovative design and fully prototype tested
UL 2200 Listed
Solid state frequency compensated
voltage
regulator
Dynamic and static battery charger
Sound attenuated acoustically designed enclosure
Whisper-Test for low noise level exercise
Acoustically designed engine cooling system
High flow low noise factory engineered exhaust system
State of the art control system with R-Series digital control panel
Rodent proof construction
High efficiency, low distortion Generac designed alternator
Vibration isolated from mounting base
Matching Generac transfer switches engineered and tested to
work as a system
All components easily accessible for maintenance
Electrostatically applied textured powder paint
FEATURES
GENERAC 2.4L ENGINE
Naturally Aspirated
Gaseous Fueled
UL 2200 Listed
Whisper-Test
Low Speed Exercise
58 dB(A) at 23 feet
Transfer Switch is sold separately
Standby Power Rating
45 kW 60 Hz CA
Liquid Cooled
Gas Engine
Generator Sets
COMMERCIAL SERIES
South Coast Air Quality Management District (SCAQMD)
Emission Certi ed For Standby Generator Application
APPLICATION
& ENGINEERING DATA
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).
COMMERCIAL 45 kW CA
GENERATOR SPECIFICATIONS
TYPE ................................................................................................................Synchronous
ROTOR INSULATION ................................................................................................ Class H
STATOR INSULATION .............................................................................................. Class H
TOTAL HARMONIC DISTORTION ..................................................................................<5%
TELEPHONE INTERFERENCE FACTOR (TIF) .................................................................. <50
ALTERNATOR OUTPUT LEADS 3 PHASE ....................................................................4 wire
BEARINGS...........................................................................................................Sealed Ball
COUPLING ....................................................................................................... Flexible Disc
LOAD CAPACITY (STANDBY RATING) ....................................................................... 45 kW
EXCITATION SYSTEM ................................................................................................. Direct
NOTE: Generator rating and performance in accordance with ISO8528-
5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Insulation is Class H rated at 150 °C rise
All models are fully prototyped tested
VOLTAGE REGULATOR
TYPE .....................................................................................................................Electronic
SENSING..........................................................................................................Single Phase
REGULATION ...............................................................................................................± 1%
FEATURES..................................................................................................... V/F Adjustable
Adjustable Voltage and Gain
LED
Indicators
CONTROL PANEL FEATURES
SEVEN LED INDICATOR LIGHTS
ADDITIONAL FUNCTIONS
System ready
Utility sensing
Low fuel pressure
Delay on utility failure for engine start
Low battery
Engine warm-up before transfer
Low oil pressure
Delay to retransfer to utility
High coolant temp/low coolant temp
Engine cooldown timer
Overspeed
Exerciser not set
Overcrank
INTERNAL FUNCTIONS:
3 position switch (auto, off and manual)
2 wire start for any transfer switch
Communicates with the Generac RTS transfer switch
Built-in 7 day exerciser
Selectable engine speed at exercise
Governor controller is built into the master control board
Temperature range -40 °
C to 70 °C
ENGINE SPECIFICATIONS
MAKE ...................................................................................................................... Generac
MODEL .....................................................................................................................Inline 4
CYLINDERS ....................................................................................................................... 4
DISPLACEMENT ...................................................................................2.4 Liter, 146 cu. in.
BORE............................................................................................................................. 3.41
STROKE ........................................................................................................................ 3.94
COMPRESSION RATIO ................................................................................................ 8.5:1
INTAKE AIR SYSTEM ..............................................................................Naturally Aspirated
VALVE SEATS ............................................................................................ Precision ground
LIFTER TYPE ...............................................................Overhead Valve Push Rod, Hydraulic
GOVERNOR SPECIFICATIONS
TYPE .....................................................................................................................Electronic
FREQUENCY REGULATION ...............................................................................Isochronous
STEADY STATE REGULATION .................................................................................± 0.25%
ENGINE LUBRICATION SYSTEM
OIL PUMP ..................................................................................................................... Gear
OIL FILTER ..................................................................................Full flow spin-on cartridge
CRANKCASE CAPACITY ......................................................................................... 4 Quarts
ENGINE COOLING SYSTEM
TYPE ...................................................................................................... Pressurized Closed
WATER PUMP ......................................................................................................Belt driven
FAN SPEED .................................................................................................................. 2060
FAN DIAMETER ..................................................................................................... 22 inches
FAN MODE ................................................................................................................ Pusher
FUEL SYSTEM
FUEL TYPE ................................................................................Natural gas, propane vapor
CARBURETOR .....................................................................................................Down Draft
SECONDARY FUEL REGULATOR ........................................................................... Standard
FUEL SHUT OFF SOLENOID .................................................................................. Standard
OPERATING FUEL PRESSURE .........................................................................5 - 14 H2O
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR .....................................................................12V 30 Amp
STATIC BATTERY CHARGER ...................................................................................... 2 Amp
RECOMMENDED BATTERY ..................................................................Group 24F, 525CCA
SYSTEM VOLTAGE.................................................................................................. 12 Volts
COMMERCIAL 45 kW CA
KW RATING
45
ENGINE SIZE
2.4 Liter
GENERATOR OUTPUT VOLTAGE/KW - 60Hz
KW
AMP
CB S