Marine Lightning Protection Inc.
pts are those described below and in a recent ProBoat
presentation
. See also a shorter discussion of these changes in
the October edition of BoatUS
Exchange
.
Our newly redesigned all-aluminum
ZzapStrap
TM
is lighter, less expensive, and comes with a PVC handle.
New products we have recently developed include rail- and surface-mountable air terminals that can be lowered,
through-topside connectors, specialized grounding strip connectors, main conductors, and connection studs, in both tinned
copper alloy and aluminum. We are now very close to our objective to provide all components needed for a lightning
protection system on vessels ranging in size from jon boats to superyachts. Our
Products
page gives our range of products
and
prices
. Upcoming additions will be detailed information about the new components and an on-line storefront. Of course,
as always, technical expertise is our forte.
Innovative lightning protection
Peer-reviewed science forms the basis
Lightning protection in the marine environment presents special challenges. As the ground attachment path for a 5-mile long spark carrying tens of
kiloamperes, the protection system has the task of safely diverting this current around crew, sensitive electronics, and hull components.
However, even when the current is flowing in the water, voltage differences can cause sideflashes, both inside the boat and between the boat and
the water. These present a shock hazard to the crew, produce overvoltage in electronics systems, and can blast holes through the hull.
Management of the sideflash problem is the fundamental issue in the design of an effective marine lightning protection system.
Our approach to lightning protection is based solidly on scientific theory and observation. The foundation was established in a
paper
published in
1991 in the peer-reviewed IEEE Transactions of Electromagnetic Compatibility. As a result of this paper, subsequent renditions of standards
published by ABYC and NFPA upgraded their recommended sizes for down conductors from #8AWG to #4AWG and noted that a ground strip is a
more effective grounding conductor than a square plate of the same area. In an attempt to find a solution to another fundamental problem revealed
in this scientific work that a one square foot ground plate is "hopelessly inadequate" to prevent sideflashes in fresh water we have the sole
license for a patent that can provide alternative techniques for grounding, and have contained to pursue the science. More recently, we have
worked with the NFPA 780 technical committee to establish a new standard base on these ideas.
Sideflash prevention is the problem
An interesting feature of hull damage is the tendency for sideflashes to form around about the waterline. Apparently either the water surface or the
waterline itself causes charges to accumulate, usually on internal conducting fittings, and initiate sparks through the hull. The effect is more
pronounced in fresh water than salt.
Photo by Dave Edwards
In lightning protection circles, the conventional solution to a problem such as this is to add conductors where the damage is observed. In the above
case this means placing lightning conductors through the hull at the waterline. Since it is impractical to install multiple ground plates in a hull, we
developed the Siedarc
TM
electrode to provide the necessary exit terminals. This is effectively an air terminal near the water. In fact, each one is
designed to the same specification as a lightning air terminal. In order to investigate the effectiveness of this concept, we tested an electrode with a
10kV generator for both salt and fresh water at Kennick Inc. in St. Petersburg. Even though 10kV is much lower than what would be expected
during a lightning strike, we obtained results that clearly indicated the promising potential for the method and further elucidated the best mode of
operation. Specifically, in the photo below, with the electrode about 1/4 "above the surface of salt water, a spark of about 15" in diameter was
produced. Clearly the sparking is contained very close to the water surface, perhaps even above it, showing the importance of the surface for
current dissipation.
In fresh water, the spark connected all the way to the sides of the container, about 12" away. In contrast, when the electrode tip was immersed just
below the water surface, a small (~
1
/
2
") glow was observed but no sparks. The conclusion is that an electrode can generate a spark that is orders
of magnitude longer than the spark gap in air when placed above the water surface. Hence the optimum placement is just above the water
surface.
The ExoTerminal
TM
system is the answer
Providing exit terminals around the perimeter of the hull is the key to an effective system design since, in addition to dispersing the current more
uniformly around the boat, it also enables the lightning down conductors to be routed externally to all wiring and conducting fittings. This is
illustrated for a sailboat below. The lightning conductor from mast base connects to both the chainplate and the loop before passing down to a
daisy-chain Siedarc
TM
electrode just above the waterline, and from there via an immersed HStrip
TM
to a keelbolt (and base of a keel-stepped
mast). Siedarc
TM
electrodes at bow and stern provide more exit terminals from the loop to the water. This geometry is mirrored on the port side.
Thus a conducting grid covers the interior of the boat and a total of nine exit terminals are distributed over the hull predominantly near the waterline.
Guiding the current on the outside rather than through the middle of the boat minimizes shock risk and emi. In addition, a bonding loop around the
boat at about deck level equalizes potentials, provides additional paths for current flow, and can be used for bonding conducting fittings. NFPA (the
National Fire Protection Association) is presently considering a revision of their watercraft standard (NFPA 780 Ch.8) to include the concepts of a
loop conductor, external down conductors, and perimeter grounding electrodes. See our
Standards
page for details. With this new system the
conductor layout more closely mirrors that found on the typical lightning protection system on a building. For a graphic demonstration of the
shielding effectiveness of a metallic cage, check out this
photo sequence
from the Boston Museum of Science. We call this system of external
lightning conductors and peripheral exit terminals the ExoTerminal
TM
protection system.
In the case of a powerboat, the external down conductors can be connected directly to air terminals that are around the perimeter. Placed using
the rolling sphere model, these can be much shorter than a single air terminal that covers the whole boat using the "cone of protection" concept.
The annotated photo below shows our first system on a passagemaker that was installed during manufacture. The lightning conductors (the blue
lines) are on the inside of the hull and the only features that might stand out as different are the two air terminals at the rear of the bridge deck.
Lightning protection system on Mirage Great Harbor 47
John Henry
We can provide all of the components needed in a marine lightning protection system, including:
·
RMAT
TM
& SMAT
TM
- air terminals with rail- or surface-mounted ratchet bases
·
ThruCon
TM
through-connector for stanchion-to-conductor continuity
·
StudCon
TM
attachment studs for connecting to strip conductors
·
Lugs heavy duty tinned copper closed-end lugs for cable terminations
·
GapCon
TM
tinned copper connector with integrated 1.5kV (nom) air gap for galvanic isolation
·
Conductors tinned copper insulated cable, tinned copper strip, aluminum cable, and aluminum strip
·
Siedarc
TM
- spark-promoting grounding electrodes embedded in non-conducting through-hulls
·
HStrip
TM
- 0.5 ft
2
tinned solid copper grounding strip, available with economical bolt connectors or state-of-the-art insulating connectors
·
HStripCon
TM
inboard coupling for combining two HStrips into the one square foot immersed area required by most standards
·
ZzapStrap
TM
- bonding & bypass cable for boat lift, trailer or jack stand.
General information on these items and their integration into a lightning protection system can be found on the
History/Problems/Solutions
page,
and specific details on these pages:
Item
Document
Contents
Siedarc
TM
Introduction
Introduction to the Siedarc
TM
electrode line
Grounding guidelines
General guidelines for using Siedarc
TM
electrodes
Grounding concepts
Physical basis for grounding electrode placement and type
Prices
Product price list
Grounding
strips
HStrip infomation
Brief description and prices of HStrip
TM
grounding strips and accessories
Prices
Product price list
ZzapStrap
TM
Information
General description of ZzapStrap
TM
system
Prices
Brief description and prices for ZzapStrap
TM
system
We also offer
consulting services
for:
·
analysis and recommendations for specific systems;
·
expert witness testimony concerning any aspect of lightning on or near water.
Please call or email if you have any questions.
Marine Lightning Protection Inc.
Phone:
+1 352 3733485
Email:
info@marinelightning.com
URL:
www.marinelightning.com
Copyright Marine lightning Protection 2007