5000 Series
The Concealite 5000 Series of emergency egress lighting
fixtures offers a unique combination of aesthetic appeal,
superior performance, and exceptional engineering.
These compact, virtually invisible emergency lighting
fixtures preserve the integrity of the architectural design
while meeting all national and state code requirements.
In new construction or remodeling, wall or ceiling
installation, Concealite fixtures work with your design
no matter what materials youre using.
*For photometric data refer to the technical section of the catalog.
Features:
Compact, completely self-contained units.
Fully automatic operation. Door is operated
by 12-volt DC motor with integral gear head.
Choice of 90-minute, 2-hour, or
4-hour operation.
Fully adjustable 12-, 20-, or 35-watt quartz
halogen lamps. Optional lamps up to 75-
watts available.º
Long-life 12-volt sealed lead calcium
recombinant battery standard. Optional
nickel cadmium batteries available.
Integral test switch and charge indicator.
Optional remote test switch, test light and
charge indicator.
Vandal resistant.
Fully automatic solid-state charger with
universal 120-/277-volt transformer. Optional
347-volt transformer available.
Designed for wall or ceiling installations,
including gypsum board, plaster, concrete,
brick, or acoustical tile applications.
Standard white powder coat finish can be
customized with paint, wallpaper, or fabric.
No minimum order for manufacturing with
custom metals (bronze, pewter, brushed
aluminum) or applying custom colors.
Self-Diagnostic controls are available, see
option section for details.
UL
®
and
5000 Series
5002-0300
Installation
This Standard System fixture utilizes a recessed flange
for flush mounting in either a wall or ceiling. This
unit requires a 7.25 (18.42 cm) high X 6.75 (17.15 cm)
opening in the wall or ceiling mounting location. For
new projects, a single enclosure is provided. The sin-
gle enclosure is mounted before the wall or ceiling
material is installed. Normal power (120-/277-V) and
remote test module connections to the unit are made
through conduit knockouts on the recessed enclo-
sure. The door, lamp, and motor drive assembly is
inserted into the recessed enclosure. The assembly is
then secured in place with 2 concealed bolts that
allow for adjustment to the wall or ceiling thickness.
For complete installation and operation instructions,
please refer to the instruction sheet included with
each shipment. For retrofits, a multi-section modular
enclosure is available. See options and technical data
section for details.
Product Specification
The emergency lighting unit shall be Concealite
Series 5000 and will conform to UL Standard #924
and be installed in accordance to Article 700 of the
National Electrical Code. The unit will be stored in a
retracted position during normal power conditions.
Upon the loss of utility power, the unit will be
702 7th Avenue Southwest
Pipestone, MN 56164
Phone: (507)825-2907
Fax: (507)825-4995
http://www.concealite.com
e-mail:
info@concealite.com
deployed into the open position and the lamps
energized. Restoration of utility power will cause
the unit to retract to the stored position and the
lamps extinguish. The unit will provide emergency
lighting for a minimum of º90 minutes. The unit
shall be constructed of cold rolled steel. Motor
shall be a 12-volt sealed permanent magnet type
with a 30-year service life. The electronics shall be
a solid state design. The maximum power draw is
no more than 15-watts. The charger will include LVD
and transfer circuits. Unit will be rated at 120-/277-
volts, 60hz (347-volt optional). The unit shall have
an integral test switch and pilot light to indicate
charge rate. Lamps shall be MR-16 type.
Limited Warranty
All Concealite equipment is guaranteed against
defects in materials and workmanship by the manu-
facturer for a period of three years from date of
shipment under normal operations and proper use.
Correction of all defects shall be by replacement or
repair (at our option) and shall constitute fulfill-
ment of all manufacturers obligations. Batteries
provided as part of unit's equipment and carry a
one year full warranty with an additional pro-rated
guarantee.
5000 Series
Ordering Information
Series
F5 - (Flush)
Lamps
12-Watt Quartz Halogen Lamps
20-Watt Quartz Halogen Lamps
35-Watt Quartz Halogen Lamps
50-Watt Quartz Halogen Lamps
75-Watt Quartz Halogen Lamps
Hours of Operation
90 -
1
1
/
2
-Hours
2
- 2-Hours
4 -
4-Hours
RT - Remote Test Module
PT - Plaster Trim
SM - Surface Mount Enclosure
VR - Vandal-Resistant Mounting Screws
CF - Custom Finish (Specify Color)
RETRO - Multi-Section Back box
(see options and technical data
section for details)
TBAR - T-Bar Mounting Kit
NC - Nickel Cadmium Batteries
NMH - Nickel Metal Hydride Batteries
SD - Self-Diagnostic
F5
20
2
Options
For installation in other building materials contact factory for details.
Test Button
Charge Light
©1999 Concealite Emergency Lighting
Please refer to the remote wiring section in the optional technical
data section of the catalog for the number of conductors needed to
control remote fixtures.
Required rough
opening in wall
or ceiling is
7.25 (18.42 cm) high