Load Life Curves for General Purpose Product Line Load Life Curves for ...
)
250 V AC resistive load
30V DC resistive load
250 V AC inductive
load (pf=0.4)
30V DC
inductive load L/R=7ms
Service life (x10
3
operations)
Relay Output Electrical endurance
0
1
10
30
50
100
300
500
1000
3000
5000
2
3
4
5
6
7
8
9
10 11
Relay Output Electrical endurance
Operations
Switching current [A]
DC voltage [Vdc]
Relay Output Maximum DC load
breaking capacity
DC current [A]
Load Life Curves for General
Purpose Product Line
Load Life Curves for Heavy
Industrial Product Line
Technical Data
Mechanical Ratings
Description
General Purpose (800Z-G)
Heavy Industrial (800Z-H)
Vibration Endurance
Tested at 10G, 1.52 mm displacement
Mechanical Shock
Tested at 100G (mechanical durability)
Degree of Protection
Type 4/4X/13, IP 66, 1200 PSI
Type 4/13, IP 66
washdown
Operating Force
Zero
Electrical Ratings
Input Voltage
Low Voltage (800Z-GL):
Low Voltage (800Z-HL):
(Relay type)
10-40V DC, 20-30V AC
10-40V DC, 20-30V AC
Full Voltage (800Z-GF): 85-264V AC
Input Voltage
Low Voltage
Full Voltage (800Z-HF):
(Solid-State type)
(800Z-GN/GP): 10-30V DC
85-264V AC
Electrical Design Life
Relay Output 200,000
Relay Output 150,000
(Relay type)
Operations @ 2A inductive,
Operations @ 5A resistive,
4A resistive
2.5A resistive
Terminal Block
IP2X rated Terminal Block
Specification
Maximum wire range
#12-22 AWG (.5-4 mm
2
),
Tightening Torque: 9 in-lbs (1Nm)
On-delay/Off-delay
60ms
Current Draw
100 mA at 24V DC = 2.23W (no external load)
(Solid-state type)
Environmental
Temperature Range
-25° C to 55° C
(operating)
Temperature Range
-40° C to 85° C
(storage)
Humidity
95% RH from 25° C to 50° C (full operation)
Materials
Housing/Guard
Valox 357
Gasket
BUNA-N
1
16
" Cork-BUNA-N
Connector
Insulator material (micro connector) = nylon
Insulator material (mini connector) = PVC
Agency Approvals
Approvals
cULus, CE, C-TICK, UR, CSA
Standards Conformity
UL 508, CSA 22.2 No. 14, UL50, EN60947-5-1, EN50081-2,
EN61000-6-2, EN60204-1, EN954-1