TC3000 Data sheet iss 2.1
00 Data sheet iss 2.1
T
C
3000
CONTROLS
DATA MANAGEMENT
PROCESS AUTOMATION
abc
Three phase thyristor for
simple resistive and inductive loads
TC 3000
Three phase thyristor for simple resistive and
inductive loads
The TC3000 is a full three phase thyristor power unit for all constant resistance or
inductive three phase loads. Three wire star or delta, four wire star with neutral and six
wire open delta load configurations can be used. It has all the firing modes needed for
simple resistive and inductive loads including phase angle for inductive loads, single cycle
for off-shore and generator applications, fast cycle for quick acting heaters and slow cycle
for very large loads. Since it is a true phase unit the TC3000 fires evenly on all phases to
match the load to the generator or supply. The self contained units are available for
currents up to 500amps.
Safety - As with all Eurotherm products the TC 3000 has been designed to ensure
operator safety and load protection. When installed and used in compliance with user
manual HA174836 it meets the essential requirements of the EEC Low Voltage Directive.
The self contained units are fully shrouded in an IP20 rated protective case with
commissioning and diagnostics points available on the front fascia. High speed
semiconductor fuses and other protection circuits are built in. Automatic alarm shutdown
protects the load and supply by quenching the thyristors if the unit detects an abnormal
event.
CE mark- The TC3000 is CE marked to show compliance with the essential protection
requirements of the Low Voltage Directive. It is designed so that it can be used as part of
a CE compliant system but it is the responsibility of the installer to establish the CE
compliance of the overall system. The TC3000 technical construction file is approved by a
Competent Body (LCIE France). A Declaration of Compliance with the European
Directives is available on request.
EMC- Eurotherm certifies that the TC3000 products, when installed and used in
accordance with their User Manual, meets the following test standards and enables the
system or installation in which they are installed to comply with the EMC Directive with
regard to the TC3000 products.
EMC tests
EMC test standards
Immunity Electrostatic discharge
EN 61000-4-2, IEC1000-4-2
(06/1995)
Fast transients
EN 61000-4-4, IEC1000-4-4
(01/1995)
Radioelectric frequency
prEN 61000-4-3
(1984)
electromagnetic fields
IEC801-3
Emission
Radiated
EN 55011-2
(1991)
The choice of the Conducted Emission application standard depends on the
application:
· EN50081-2 (1991)
- Without external filter in Burst firing on resistive load up to 150A nominal
- With an external series filter for other configurations
· prEN 61800-3 (1996)
- Without external filter
Applies to the second environment (industrial environment)
External series filters
To reduce the conducted emissions that occur when using thyristor units, Eurotherm can supply
external filters.
Nominal current of TC3000
Serial filter order code
25A to 60A
FILTER/TRI63A/00
75A and 100A
FILTER/TRI/100A/00
Above 100A consult your Eurotherm office.
TECHNICAL SPECIFICATION
Current
25A to 500A
Voltage
240V to 500V (+10%, -15%) line voltage. 100V to 500V operating voltage
Supply frequency
42Hz to 68Hz with automatic sensing. Unit inhibited outside 40Hz to 70Hz
Auxiliary supply
100V to 240V (+10%, -15%). Selected when ordering. Consumption 20VA plus fans (see below)
Environment
Pollution degree 2 (IEC 664)
Altitude
Maximum altitude 2000m
Storage temperature
-10°C to 70°C
Operating temperature
0°C to 50°C with unit mounted vertically. 40°C for 500A units (50°C if derated to 450A)
Cooling
Natural cooling up to 75A
Two fans for 100A and 250A, (additional auxiliary supply consumption 25VA per fan)
Three fans from 300A to 500A, (additional auxiliary supply consumption 25VA per fan)
Over temperature shut down for fan cooled units
Power dissipation
Allow for 2Watts per amp per phase (includes thyristors and fuses)
Humidity
5% to 95% RH non condensing
Enclosure protection
IP20 (IEC 529)
Electrical safety
Complies with EEC Low Voltage Directive 73/23/EEC dated 19/2/73 amended by directive 93/68/EEC dated 22/7/93
EN 61010 installation category 3 ( voltage transients must not exceed 4.0KV)
Electrical protection
RC snubber network and varistor
Built in high speed fuses for thyristor protection only. Line protection to be provided separately
Load
Load types
Any three phase constant resistance or inductive load
Load configuration
3 wire star, 4 wire star with neutral, 3 wire delta, 6 wire open delta
Control type
Three phases of a three phase system
Phase rotation
Phase rotation insensitive - connect phases in any order
Operation
Firing modes
Logic: Cycle time defined by logic input, Single Cycle, Burst (1-255 cycles), Phase Angle, Soft Start and/or End to burst
Power ramps
Setpoint ramp after reset
Control
Analogue input
Voltage: 0-5V, 1-5V, 0-10V, 2-10V.
Input impedance > 100k
Current: 0-20mA, 4-20mA.
Input impedance = 100
Second input
Same input ranges, as first input - lowest wins
Logic input
Range selected from analogue input. 50% =ON, <25%=OFF
Control mode
Open loop, V
2
or external feedback
Linearity
Phase angle ±1% , Burst firing ±2% for all feedback modes
Stability
Phase angle ±1% , Burst firing ±2% for +10% to -15% supply variation, for 0°C to 50°C ambient temperature
Enable/inhibit
Logic input of +10V enables operation
Alarm
Loss of any supply phase, under voltage - below 70% or 50%, over voltage above 20% of nominal, frequency error, external
measurement signal failure. Thermal switch operation. Any of these will give an alarm
Options
Fuse fail microswitches
Alarm contacts closed in alarm state (open as standard)
DIMENSIONAL DETAILS
248 mm (25 to 250A)
373 mm (300 to 500A)
268 mm (537 mm with door open)
570 mm (300 to 500A)
480 mm (25 to 250A)
Protection cover
Earth
Load Terminal
Weight: Up to 150A -16kg, 250A - 18kg, 300A to 500A - 21kg
TC 3000
Basic
Product
Current
Maximum
Voltage
Auxiliary
Supply
Operating
Voltage
Input
Firing
Mode
Ramp. soft
start/end
Load
Connection
Load
Type
Controlled
Parameter
Aux.
Input/Outp Options
Current
Code
25 amps
25A
40 amps
40A
60 amps
60A
75 amps
75A
100 amps
100A
150 amps
150A
250 amps
250A
300 amps
300A
400 amps
400A
500 amps
500A
fan cooled
Maximum Line to Line Voltage
240 volts
240V
440 volts
440V
480 volts
480V
500 volts
500V
Auxiliary Supply
100 volts
100V
110 to 120 volts
110V120
200 volts
200V
220 to 240 volts
220V240
Operating Voltage
100 volts
100V
110 volts
110V
115 volts
115V
120 volts
120V
200 volts
200V
Code
220 volts
220V
230 volts
230V
240 volts
240V
277 volts
277V
380 volts
380V
400 volts
400V
415 volts
415V
440 volts
440V
480 volts
480V
500 volts
500V
Input
0-5 volts
0V5
1-5 volts
1V5
0-10 volts
0V10
2-10 volts
2V10
0-20mA
0mA20
4-20mA
4mA20
Firing Mode
Logic (On/Off)
LGC
Phase angle
PA
Burst
1 period
FC1
2 periods
FC2
4 periods
FC4
8 periods
FC8
16 periods
C16
32 periods
C32
64 periods
C64
128 periods
128
255 periods
255
Part No. HA023755 Issue 2.1
Printed in England 08.01
ORDERING CODE
EUROTHERM LIMITED http://www.eurotherm.co.uk
email: info@eurotherm.co.uk
© Copyright Eurotherm Limited 2001
All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm
Limited. Every effort has been taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our
products which could, without notice, result in amendments or omissions to this specification. We cannot accept responsibility for damage, injury loss or expenses resulting
therefrom.
UK SALES OFFICE
Eurotherm Ltd
Faraday Close Durrington Worthing BN13 3PL United Kingdom
Sales and support: Tel. +44 (0)1903 695888 Fax +44 (0)1903 695666
Sales and support in over 30 countries worldwide
Enquiries/orders to:
Eurotherm Ltd Faraday Close Durrington
Worthing BN13 3PL United Kingdom
Tel. +44 (0)1903 268500 Fax +44 (0)1903 265982
Ramp, soft start/end
Code
No ramp
NRP
Soft start of burst
URP
Soft start and end of burst
UDR
Load Connection
3 Wire delta
3D
3 Wire star
3S
4 Wire star with neutral
4S
6 Wire open delta
6D
Load Type
Inductive
IND
Resistive
RES
Control Mode (feedback)
V
2
V2
External (see inputs and outputs)
EX
Open loop
OL
Inputs and Outputs
0-10V controlled parameter retransmission
RTR
0-10V external feedback (if EX selected)
E0VI0
0-10V second setpoint
W0VI0
Options
Fuse fail microswitch
FUMS
Alarm contacts closed in alarm state
IPU
EXTRAS
Code
Diagnostic unit (240V)
260-13-00