Seanet System (Subsea Junction Box) Operator & Installation Manual
font face=arial size=-1 color=black>Yahoo! is not affiliated with the authors of this page or responsible for its content.
Seanet System (Subsea Junction Box) Operator & Installation Manual
Issue 1
TIL Eng Spec 076
Seanet System J- Box OIM
Supplied
by:
Seanet System
(Subsea Junction Box)
Operator & Installation
Manual
The electronic version of this document is the controlled copy.
Therefore all printed versions of this document are uncontrolled.
For the latest manual revision always visit www.tritech.co.uk
F063.1
COPYRIGHT
© Tritech International Ltd
The copyright in this document is the property of Tritech International
Limited. The document is supplied by Tritech International Limited on
the understanding that it may not be copied, used, or disclosed to
others except as authorised in writing by Tritech International Limited.
Tritech International Limited reserved the right to change, modify and
update designs and specifications as part of their ongoing product
development programme.
Tritech International Ltd
Seanet System J-Box OIM
Issue 1
TIL Eng Spec 076
Page 4 of 28
Handling of Electrostatic-Sensitive Devices.........................................................................................5
Safety Statements ...................................................................................................................................7
Technical Support ..................................................................................................................................7
INTRODUCTION
...................................................................................................................................8
KEY
FEATURES:...............................................................................................................................8
Functionality
....................................................................................................................................8
Telemetry Options
.........................................................................................................................8
Power Distribution
..........................................................................................................................8
System Compatibility
.....................................................................................................................9
Configuration
..................................................................................................................................9
OPERATIONAL OVERVIEW
............................................................................................................10
S
WITCH
O
PTIONS
...............................................................................................................................11
SEANET OPERATION
.......................................................................................................................12
1.
ARCNET
TO SURFACE
/
ARCNET
TO SUBSEA
S
ENSORS
...................................................12
System Power
..............................................................................................................................13
System Telemetry
........................................................................................................................13
Junction Box Wiring - SeaKing ARCNET In & ARCNET Out
................................................14
Mating Connector Wiring
............................................................................................................14
2.
RS-232
TO SURFACE
/
ARCNET
TO SUBSEA
S
ENSORS
......................................................15
System Power
..............................................................................................................................15
System Telemetry
........................................................................................................................15
Junction Box Wiring - SeaKing RS232 In & ARCNET Out
...................................................16
Mating Connector Wiring
............................................................................................................16
Checking Connection in the Seanet Setup program
..............................................................17
Changing RS-232 Baud Rate
....................................................................................................18
Establishing RS-232 link using (Recovery) 9600 Baud Speed
.............................................20
APPENDIX 1.
.......................................................................................................................................23
Figure 1:
Junction Box Dimensions
...................................................................................23
Figure 2:
SeaKing Connection Option 1
............................................................................24
Figure 3:
SeaKing Connection Option 2
............................................................................25
Figure 4:
SeaKing AIF Card Communications Port
.........................................................26
APPENDIX 2.
.......................................................................................................................................27
SUBSEA JUNCTION BOX INTERNAL FUSES.
...........................................................................27
Fuse Location
...............................................................................................................................27
Tritech International Ltd
Seanet System J-Box OIM
Issue 1
TIL Eng Spec 076
Page 5 of 28
Handling of Electrostatic-Sensitive Devices
Attention
Observe Precautions for handling
Electrostatic Devices
Caution
Handling of Electrostatic-Sensitive Devices
Certain semiconductor devices used in the equipment are liable to damage due to static voltages.
Observe the following precautions when handling these devices in their unterminated state, or sub-units
containing these devices:
Persons removing sub-units from any equipment using electrostatic sensitive devices must be earthed by a
wrist strap via a 1M resistor to a suitable discharge reference point within the equipment.
Soldering irons used during any repairs must be low voltage types with earthed tips and isolated from the
Mains voltage by a double insulated transformer. Care should be taken soldering any point that may have a
charge stored.
Outer clothing worn must be unable to generate static charges.
Printed Circuit Boards (PCBs) fitted with electrostatic sensitive devices must be stored and transported in
appropriate anti-static bags/containers.
F110.0
Tritech International Ltd
Seanet System J-Box OIM
Issue 1
TIL Eng Spec 076
Page 6 of 28
Warranty Statement
Tritech International Limited
herein after referred to as
TIL
TIL warrants that at the time of shipment all products shall be free from defects in material and workmanship and suitable
for the purpose specified in the product literature.
The unit/system warranty commences immediately from the date of customer acceptance and runs for a period of 365
days. Customer acceptance will always be deemed to have occurred within 72 hours of delivery.
Note:
Any customer acceptance testing (if applicable) must be performed at either TIL premises or at one of their
approved distributors unless mutually agreed in writing prior to despatch.
Conditions:
These include, but are not limited to, the following:
1
The warranty is only deemed to be valid if the equipment was sold through TIL or one of its approved distributors.
2
The equipment must have been installed and commissioned in strict accordance with approved technical
standards and specifications and for the purpose that the system was designed.
3
The warranty is not transferable, except or as applies to Purchaser first then to client.
4
TIL must be notified immediately (in writing) of any suspected defect and if advised by TIL, the equipment subject
to the defect shall be returned by the customer to TIL, via a suitable mode of transportation and shall be freight
paid.
5
The warranty does not apply to defects that have been caused by failure to follow the recommended installation or
maintenance procedures. Or defects resulting from normal wear & tear, incorrect operation, fire, water ingress,
lightning damage or fluctuations in vehicles supply voltages, or from any other circumstances that may arise after
deliver