RATIO:FEEDER PRICE $5.00
RATIO:FEEDER
®
SERIES J PLUS
PUMPER CONTROLLERS
See Quick Start information
on page ii
NOTICE: Check immediately upon receipt for damaged parts.
If some are found, save all packing material and parts, and
notify the delivering carrier. They are responsible.
Made in the USA
Serving our customers since 1956 J Plus injector system with optional acid pumper.
Copyright © 1996, 2004 by H.E. Anderson Company J-31b 02/04
i
H.E. Anderson company
Manuals are provided for these major assemblies
Pumpers
Manifolds or Banks
Series J Plus
Controllers
GETTING TECHNICAL ASSISTANCE
The H.E. Anderson Company is anxious to assist our customers with installa-
tion and use of our products. Our technical people are available each weekday
from 8:30 a.m. to 4:30 p.m. central time. You may call us toll free at
1-800-331-9620 from anywhere in the U.S.A. and Canada If no one is avail-
able, we will promptly return your call.
Before you call, we suggest that you review this manual. You may find the
answer to your question there. But even if you do not, reviewing the manual will
help us to help you.
There is some information you should have available when you call. You
should know the program number and serial number of your control unit. Also,
you should note the number of pumpers of each type, and their model numbers.
We may not need all this information, but having it available at the start can
sometimes save a lot of time and trouble for you. You may record the informa-
tion below for convenient reference. NOTE: The program number can be dis-
played by pressing both the
é and ê keys together.
SERIAL _________________ PROGRAM NUMBER _______________
PUMPER #1 ______________
PUMPER #6 _______________
PUMPER #2 ______________
PUMPER #7 _______________
PUMPER #3 ______________
PUMPER #8 _______________
PUMPER #4 ______________
PUMPER #9 _______________
PUMPER #5 ______________
PUMPER #10 ______________ H.E. Anderson company
ii
J-31b 02/04
J PLUS QUICK START INFORMATION
MODEL NO. _____________ SERIAL NO. ______________
Do all wiring before connecting power. Use a surge suppresser on the incoming a.c.
power line. Plug in the power cord and watch the LCD display. If it does not come on,
unplug the power and check the wiring.
This unit was ordered with the following capacities or settings:
CUSTOMER REQUESTED ___ DEFAULT ___
PROGRAM NUMBER
__________
K FACTOR
__________
MAXIMUM FLOW
__________
GALLONS/LITERS PER STROKE #1 __________ (OUTPUT #1)
GALLONS/LITERS PER STROKE #2 __________ (OUTPUT #2)
GALLONS/LITERS PER STROKE #3 __________ (OUTPUT #3)
GALLONS/LITERS PER STROKE #4 __________ (OUTPUT #4)
With the above settings, pumpers will have the following chemical to water feed
ratio capacities (At dial setting 10).
BASE #1 = (OUTPUT #1 x 3785)
40
H4, P4
1:______ (BASE #1)
H2, P2 1:______ (BASE #1 x 2)
H1, P1, A10 1:______ (BASE #1 x 4)
A3
1:______ (BASE #1 x 13.3)
BASE #2 = (OUTPUT #2 x 3785)
40
H4, P4
1:______ (BASE #2)
H2, P2 1:______ (BASE #2 x 2)
H1, P1, A10 1:______ (BASE #2 x 4)
A3
1:______ (BASE #2 x 13.3)
BASE #3 = (OUTPUT #1 x 3785)
40
H4, P4
1:______ (BASE #3)
H2, P2 1:______ (BASE #3 x 2)
H1, P1, A10 1:______ (BASE #3 x 4)
A3
1:______ (BASE #3 x 13.3)
BASE #4 = (OUTPUT #1 x 3785)
40
H4, P4
1:______ (BASE #4)
H2, P2 1:______ (BASE #4 x 2)
H1, P1, A10 1:______ (BASE #4 x 4)
A3
1:______ (BASE #4 x 13.3)
If more than one pumper is used to pump the same chemical, divide the ratio (BASE)
by the number of pumpers used for that chemical.
To verify the settings, press the indicated keys.
SET
To display the K FACTOR
SET +
é
To display GAL/L PER STROKE #1
(2 outputs)
SET +
ê
To display GAL/L PER STROKE #2
(2 outputs)
SET +
é or ê
To sequence GAL/L PER STROKE #1-4 (4 outputs)
é + ê
To display the PROGRAM NUMBER
To change a setting, first display it; then press SET and ENTER together until the
display blinks. Then use
é or ê to set. Then press ENTER.
IMPORTANT! READ YOUR MANUAL
If the PROGRAM NUMBER, the K FACTOR, or the GALLONS PER STROKE are
changed, the feed ratio will also change.
Be careful! Read Section 3 of this manual for
more information about changing any settings or contact the factory.
Note: The K FACTOR can be changed only during the first minute after power-up.
(See Section 3.4) C O N T E N T S
J PLUS QUICK START INFORMATION .
.
.
.
.
.
.
.
.
.
.
.
.
i
RATIO:FEEDER® LIMITED WARRANTY . . . . . . . . . . . . . . . . . iv
1.0
INTRODUCTION
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
1.1
INSTALLATION GUIDELINES . . . . . . . . . . . . . . . . . . 2
1.1.1
Access .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2
1.1.2
Environment .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2
1.1.3
Safety
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2
1.1.4
Location.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
1.1.5
Water Hammer
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
1.1.6
Water Quality .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
1.2
UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.0
ASSEMBLY AND INSTALLATION
.
.
.
.
.
.
.
.
.
.
.
.
3
2.1
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . 4
3.0
SETTING THE CONTROLLER .
.
.
.
.
.
.
.
.
.
.
.
.
.
4
3.1
SETTING THE JUMPERS . . . . . . . . . . . . . . . . . . . . 5
3.2
POWERING UP THE UNIT . . . . . . . . . . . . . . . . . . . 5
3.3
DISPLAYING THE PROGRAM NUMBER . . . . . . . . . . . . . 5
3.4
SETTING THE K FACTOR . . . . . . . . . . . . . . . . . . . 5
3.5
SETTING THE OUTPUTS. . . . . . . . . . . . . . . . . . . . 7
3.5.1
Dual Output Models.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
3.5.2
Quad Output Models
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
3.6
CLEARING MEMORY . . . . . . . . . . . . . . . . . . . . . 8
4.0
OPERATION .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
8
4.1
INITIAL CHECK-OUT
. . . . . . . . . . . . . . . . . . . . . 8
4.2
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.3
MANUALLY PULSING THE OUTPUTS . . . . . . . . . . . . . . 8
4.3.1
Dual Output Models.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
8
4.3.2
Quad Output Models
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
4.4
THE FLOW VOLUME TOTALIZER . . . . . . . . . . . . . . . . 9
4.4.1
Reading the Flow total .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
4.4.2
Resetting the Total .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
J-31b 02/04
iii
H.E. Anderson company 5.0
MAINTENANCE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
6.0
STORAGE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
7.0
TROUBLESHOOTING .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
7.1
CHECKING THE METER SENSOR . . . . . . . . . . . . . . . 10
7.2
PUMPER AND DIAPHRAGM PROBLEMS . . . . . . . . . . . . 10
8.0
REPAIR .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
11
8.1
FUSE REPLACEMENT
. . . . . . . . . . . . . . . . . . . . 11
9.0
FACTORY SERVICE.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
11
TABLES
TABLE 1 JUMPER POSITIONS . . . . . . . . . . . . . . . . . . . . 5
TABLE 2 PROGRAMS & SETTINGS (US gallons) . . . . . . . . . . . . 6
TABLE 3 PROGRAMS & SETTINGS (liters)
. . . . . . . . . . . . . . 6
TABLE 4 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . 11
FIGURES
1
Series J Plus Controller . . . . . . . . . . . . . . . . . . . . . . 1
2
J Plus front and rear circuit boards (2-Output)
. . . . . . . . . . . 1
3
J Plus front and rear circuit boards (4-Output)
. . . . . . . . . . . 2
APPENDICES
APPENDIX A. Specifications and Operating Requirements . . . . . . . A-1
J Plus Control Box Parts Drawing . . . . . . . . . . . . . . . . A-2
APPENDIX B.
Formulas and Examples . . . . . . . . . . . . . . . . B-1
APPENDIX C. Typical Installation Drawings . . . . . . . . . . . . . C-1
Standard Unit Assembly Drawings . . . . . . . . . . . . . . . . C-4
H.E. Anderson company
iv
J-31b 02/04 1 INTRODUCTION
The Series J Plus Ratio:Feeder® injectors are
designed to be the most accurate and trouble
free available. The control unit, consisting of
the meter measuring unit and electronics
should be virtually maintenance free. There
are two models of J Plus controllers; one with
dual valve outputs and one with quad valve
outputs. All outputs are independently
programable.
This allows you to feed different
chemicals at different stroking rates. This
manual covers both types. Specifications for
these systems are given in Table 1, page 7,
and Appendix A. in the rear of this manual.
This manual covers assembly and installation
of the injector. It also covers operation and
maintenance of the control unit. The injector
pumpers and manifold pilot valve are covered
J-31b 02/04
1
H.E. Anderson Co.
Series J Plus Ratio:Feeder® Systems
Figure 2
J Plus (2-Output) front and rear circuit boards,
shown with serial communications option.
Mem ory clear jumper (See sec tion 3.6)
Op tional com mu ni ca tions
com po nents
Jumper pins
(See Sec tion
3.1)
MARKED EDGE
THIS SIDE
Shown with safety cover re moved
Trans former
1 2 1 2 L N
Valve 1 Line in
Valve 2
1 2 3
Flow
sen sor
i