General:
- The recoil action is provided by a solenoid within each gun.
- The solenoid is powered by the 24 VDC power supply (included).
- The recoil action is enabled only when a coin is dropped into the game and the start button is
pushed.
- The recoil action will be disabled after the last trigger pull and a time delay.
- The time delay is adjustable from 20 seconds to one minute. If the trigger is not pulled in this set
amount of time the recoil will cease. Another coin will be necessary to enable the solenoid again.
The gun will still operate during this time (except for the solenoid), if the game is playing.
Diagram of the Recoil Gun Control PCB
&
Player 2 & 1 solenoid turn-off delay
adjustment (See Solenoid Turn-Off Delay
adjustment settings table)
- To Player 1 Happ
Recoil Gun
- To Game Board Player 1 Gun
Connection
- To Game Board Player 2
Gun Connection
- To Player 2 Happ
Recoil Gun
To Player 1 & 2
To +5 VDC from Game Cabinet and +24 VDC
from Power Supply
J6
J1
J4
J5
J3
J2
S1
S2
S2
S1
J2
J3
J5
J4
J1
J6
Coin & Start switches
Connection Instructions:
1. Mount the Recoil Gun Control PCB in a convenient location using the PCB feet either before or
after these connections are made.
Power Supply Connections -
:
2. Connect 120 VAC from the game cabinet to the 120 VAC terminals on the
power supply. Be sure to connect an earth ground to the FG terminal
3. Find the 7 pin wire harness with a Red, a Violet and 2 Black wires.
3a. Connect one Black wire to GND on the power supply.
3b. Connect the Violet wire to the +24 terminal on the power supply.
3c. Connect the Red wire to +5 VDC from the game cabinet.
3d. Connect the other Black wire to the game cabinet power supply common.
4. Mount the power supply in a convenient location inside the game cabinet.
Coin and Start Connections -
:
5. Find the 6 pin wire harness with a Blue, Blue/White, Green and Green/White and Black wires.
Connect the following wires to the Normally Open (NO) terminals of the indicated switch. The NO
contact is marked on the switch. There will already be wires on these terminals. Do not disconnect
those. The above wires need to be added to the switch terminals and the existing wires.
5a. Connect Blue to Coin 1
5b. Connect Blue/White to Start 1
5c. Connect Green to Coin 2
5d. Connect Green/White to Start 2
5e. Connect the Black wire to one of the switch common (COM) terminals along with the
existing wires.
NOTE: On games with only one coin switch, connect the blue and green wires (Coin 1 and Coin 2)
together.
Connections from the Recoil Gun Control PCB to the Game PCB-
&
:
Player 1:
6. Find the wire harness with a Red, White, Black, Blue and Green wires. This will connect to Recoil
PCB
. Connect the other end of the harness to the Game PCB Player 1 Gun Connections
as follows:
6a. Connect Red to +5 VDC
6b. Connect White to Trigger
6c. Connect Black to common
6d. Connect Blue to the Optic signal
The Green wire is intended for those games that have two buttons on the gun. Normally it is not
connected.
Player 2:
7. Find the wire harness with a Red, White/Black, Black, Blue/Black and Green/black wire. This will
connect to Recoil PCB
. Connect the other end of the harness to the Game PCB as follows:
7a. Connect Red to +5 VDC
7b. Connect White/Black to Trigger
7c. Connect Black to common
7d. Connect Blue/Black to the Optic signal
The Green/Black wire is intended for those games that have two buttons on the gun. Normally it is
not connected.
NOTE: Refer to your Game Manual for the proper Game PCB connectors, wire colors, etc.
J5
J3
J5
J3
J1
J6
HI-PO
T
TEST
ED
OK
Connections from the Happ Recoil Guns to the Recoil Gun Control PCB
&
:
Connect Player 1 Recoil Gun to
and Player 2 Recoil Gun to
.
IMPORTANT! After installation, re-calibrate the gun accuracy
using the calibration set-up in the Game software.
Setting Solenoid Turn-Off Delay:
The following applies to DIP Switches
and
. Set both switches
the same way:
S2
S1
J4
J2
J4
J2
H
APP
C
ONTROLS
106 Garlisch Drive Elk Grove, IL 60007
TEL: 847-593-6130 FAX: 847-593-6137 TOLL FREE PHONE: 888-BUY-HAPP (289-4277)
TOLL FREE FAX: 800-593-HAPP (4277)
H
APP
C
ONTROLS
LAS VEGAS BRANCH
5175 S. Valley View Blvd. Las Vegas, NV 89118
TEL: 702-891-9116 FAX: 702-891-9117 TOLL FREE PHONE: 800-831-0444 TOLL FREE FAX: 877-870-2259
REV. 11/10/00
SOLENOID TURN-OFF DELAY
SWITCH 1
SWITCH 2
SWITCH 3
TURN-OFF DELAY
ON
OFF
OFF
ALWAYS ENABLE
OFF
ON
ON
20 SECONDS
OFF
ON
OFF
40 SECONDS
OFF
OFF
OFF
1 MINUTE