vehicular gate operator installation instructions and safety information
=black height=1 colspan=2>
vehicular gate operator installation instructions and safety information
Q-4
vehicular
gate operator
installation instructions and
safety information
CLASS I, CLASS II, CLASS III and CLASS IV
LISTED 18TC
UL 325
UL 991
Viking Access Systems
T 800.908.0884 F 949.753.1640
631 Wald - Irvine, CA 92618
vikingaccess.com
revision A1 february 2007
1
2
10
23
28
7
8
6
5
9
11
4
25
15
20
19
22
3
18
24
16
17
26
27
(2)
13
14
(2)
(2)
(2)
(2)
12
Item Description
Part No.
1
Main Chassis
Q4MCH10
2
Chassis Top Cover
Q4MCTC10
3
Chassis Front Cover
Q4MCFC10
4
Chain Guard
Q4CHGA10
5
Q4 Motor
Q4MO10
6
Motor Brake
Q4MOB10
7
Limit Switch 2
DULS10
8
Limit Switch Cam 2
DSLC10
9
Limit Switch Plate
DSLH10
10 Limit Switch Gear Box
DSLSGB10
11 Electric Box
DUEB10
12 Control Board\
Q4CB10
13 Batery 33 Ahr
DUBA33
14 Battery Fuse Holder
Q4BFH
15 Transformer 15amp X 2
DUTT15
16 Power Supply
Q4POSU10
17 EMI Board
DUEMIQ4
18 Alarm
DULA10
19 Limit Switch Harness
Q4LSH
20 Power Harness
Q4POH10
21 Power Supply Housing
Q4POSH10
22 Battery Retainer
Q4BRE10
23 Fuse Kit
Q4FK10
24 Chain #50X10'X3
Q450CH
25 Sprocket 50B25
Q4S50B25
26 Idler Pulley
Q4IDPLY
27 Idler Bushing
Q4IDBSH
28 Warning Placard
DUWPA
Overall Dimensions
TECHNICAL SUPPORT 1 800 908 0884
i
PARTS DIAGRAM
PARTS DIAGRAM
WARNING - For Installation
By Qualified Personnel Only.
20"
14"
26"
0.625"
15.75"
Center of
Drive Chain
26"
13.75"
11.75"
2.60"
TECHNICAL SUPPORT 1 800 908 0884
1
TABLE OF CONTENTS
TABLE OF CONTENTS
Parts Diagram/Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i
Important Safety Information
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Important Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Maintenance/General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Photo Beam (non-contact sensor) Installation . . . . . . . . . . . . . . . . . . . . . . . . . .6
Edge Sensor (contact sensor) Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Manual Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Audible Alarm Reset Switch Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Warning Placard Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Important Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Plans of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Plan of Installation Concrete Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Gate Operator Installation
Step 1 through 3 Operator Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13
Electrical Installation
Step 4 Electrical Installation (120/220 VAC) . . . . . . . . . . . . . . . . . . . . . . . . . .14
Step 5 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Gate Operator Installation
Limit Switch Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Step 6 through 8 Limit Switch Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17
Special Features
Fine Tune Limit Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Electrical Installation
Master/Slave Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Vehicular Loop Detector Installation
Loop Layout Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Accessory Connections
Open Commands; Safety Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Radio Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Guard Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Special Features
Intelligent Obstruction Sensor (Primary Entrapment Protection) . . . . . . . . . . . . .25
Fail Safe/Fail Secure Operation; Hold Open Timer . . . . . . . . . . . . . . . . . . . . . . .26
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27-29
TECHNICAL SUPPORT 1 800 908 0884
2
WARNING - Not following these instructions may cause severe injury or death to persons.
IMPORTANT SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS
WARNING To reduce the risk of severe injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF
THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or when
an object activates the non-contact sensors. After adjusting the force or the limit of travel,
retest the gate operator. Failure to adjust and retest the gate operator properly can increase the
risk of injury or death.
5. Use the manual release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owners manual. Have a qualified service per-
son make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. Every gate operator installation M
MU
US
ST
T have secondary protection devices
against entrapment, such as edge sensors and photo beams more in particularly
in places where the risk of entrapment is more likely to occur.
9. SAVE THESE INSTRUCTIONS.
IMPORTANT INSTALLATION INSTRUCTIONS
1. Install the gate operator only when:
a) The operator is appropriate for the construction of the gate and the usage Class of the gate
(refer to page 5),
b) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate
to a minimum of 4 feet (1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm)
diameter sphere from passing through the openings anywhere in the gate, and in that
portion of the adjacent fence that the gate covers in the open position,
c) ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED, AND
d) GUARDING IS SUPPLIED FOR EXPOSED ROLLERS.
2. The operator is intended for installation only on gates used for vehicles. Pedestrians must be
supplied with a separate access opening. The pedestrian access opening shall be designed to
promote pedestrian usage. Locate the gate such that persons will not come in contact with the
vehicular gate during the entire path of travel of the vehicular gate.
3. The gate must be installed in a location so that enough clearance is supplied between the gate
and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging
gates shall not open into public access areas.
4. The gate must be properly installed and work freely in both directions prior to the installation
of the gate operator. Do not over-tighten the operator clutch or pressure
relief valve to compensate for a damaged gate.
5. The gate operator controls must be placed so that the user has full view
of the gate area when the gate is moving AND AWAY FROM THE GATE
PATH PERIMETER,
TECHNICAL SUPPORT 1 800 908 0884
3
WARNING - Not following these instructions may cause severe injury or death to persons.
IMPORTANT SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
6. Controls intended for user activation must be located at least six feet (6) away from any mov-
ing part of the gate and where the user is prevented from reaching over, under, around or
through the gate to operate the controls. Outdoor or easily accessible controls shall have a secu-
rity feature to prevent unauthorized use.
7. The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the
reset control shall not cause the operator to start.
8. All warning signs and placards must be installed where visible in the area of the gate. A minimum
of two placards shall be installed. A placard is to be installed in the area of each side of the
gate and be visible to persons located on the side of the gate on which the placard is installed.
9. For gate operators utilizing a non-contact sensor (Photo beam or like) in
accordance with section 31.1.1 of the UL325 standard:
a) See instructions on the placement of non-contact sensors for each Type of
application (refer to page 6),
b) Care shall be exercised to reduce the risk of nuisance tripping, such as when
a vehicle, trips the sensor while the gate is still moving, and
c) One or more non-contact sensors shall be located where the risk of entrapment
or obstruction exists, such as the perimeter reachable by a moving gate or
barrier (refer to page 6).
d) Use only Omron E3K-R10K4 photoelectric eye to comply with UL325
10. For a gate operator utilizing a contact sensor (Edge sensor or like) in
accordance with section 31.1.1 of the UL325 standard:
a) One or more contact sensors shall be located where the risk of entrapment or
obstruction exists, such as at the leading edge, trailing edge, and post mounted
both inside and outside of a veh