Home Standby – 7kW / 12kW / 15kW

omponent
testing, reliability testing, environmental testing, destruction and life
testing, plus testing to applicable CSA, NEMA, EGSA, and other
standards, allows you to choose GENERAC POWER SYSTEMS with
the confidence that these systems will provide superior performance.
TEST CRITERIA:
PROTOTYPE TESTED
SYSTEM TORSIONAL TESTED
NEMA MG1 EVALUATION
MOTOR STARTING ABILITY
SOLID-STATE,
FREQUENCY
COMPENSATED
VOLTAGE
REGULATION.
This state-of-the-art power maximizing regulation
system is standard on all Generac models. It provides optimized FAST
RESPONSE to changing load conditions and MAXIMUM MOTOR
STARTING CAPABILITY by electronically torque-matching the surge
loads to the engine.
SINGLE SOURCE SERVICE RESPONSE
from Generacs dealer
network provides parts and service know-how for the entire unit, from
the engine to the smallest electronic component.You are never on your
own when you own a GENERAC POWER SYSTEM.
GENERAC TRANSFER SWITCHES,
SWITCHGEAR AND
ACCESSORIES.
Long life and reliability is synonymous with
GENERAC POWER SYSTEMS. One reason for this confidence is that
the GENERAC product line includes its own transfer systems,
accessories, switchgear and controls for total system compatibility.
FEATURES
Air-Cooled Gas Engine Generator Sets
Model # 004673 7kW 60Hz
Model # 004674 12kW 60Hz
Model # 004675 15kW 60Hz
INCLUDES:
Flexible Fuel Line
Composite Mounting Pad
Natural Gas or LP Gas Operation
UL 2200 Listed
Standby Power Rating HOME STANDBY SPECIFICATIONS
Home Standby 7kW / 12kW / 15kW
E
N
G
I
N
E
Generac (OHVI) Design
Spiny-lok cast iron cylinder walls
Electronic ignition, spark advance
and compression release
Full pressure lubrication system
Low oil pressure shutdown system
High temperature shutdown
Revolving field
Skewed stator
Displaced phase excitation
Automatic voltage regulation
UL 2200 Listed
Fully Automatic
100 or 200 Amp (options)
Remote Mounting
UL Listed
Manual/Auto/Off switch
Utility voltage sensing
Utility interrupt delay
Engine warm-up
Engine cool-down
Seven day exerciser
Timed Trickle Battery charger
Main Line Circuit Breaker
Weather protective enclosure
Enclosed critical grade muffler
Small, compact, attractive
1 Flexible Fuel Line
Composite Mounting Pad (Std)
Maximizes engine breathing for increased fuel efficiency. Cylinder walls run cooler, reducing
oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly
longer life than competitive engines.
Rigid construction and added durability provide long engine life.
These features combine to assure smooth, quick starting every time.
Superior lubrication to all vital bearings means better performance, less maintenance and significantly
longer engine life.
Superior shutdown protection prevents catastrophic engine damage due to low oil.
Prevents damage due to overheating.
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Produces a smooth output waveform for compatibility with electronic equipment.
Maximizes motor starting capability. Provides more surge capability than brushless generator designs.
Regulates the output voltage to ±2% prevents damaging voltage spikes.
For your safety
Transfers your vital electrical loads to the energized source of power.
Required (order separately)
Mounts near your existing distribution panel for simple, low cost installation.
For your safety
Selects the operating mode.
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage.
Prevents nuisance start-ups of the engine, set point approximately 10 seconds.
Ensures
engine is ready to assume the load, setpoint approximately 10 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages.
Maintains battery voltage to insure starting.
Protects generator from overload.
Ensures protection against mother nature. Hinged key locking roof panel for security.
Electrostatically applied powder paint for durability.
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Makes for an easy, eye appealing installation.
Easy Installation
G
E
N
E
R
A
T
O
R
T
R
A
N
S
F
E
R
S
W
I
T
C
H
(
O
P
T
)
I
N
S
T
A
L
L
A
T
I
O
N
K
I
T
M
I
C
R
O
P
R
O
C
E
S
S
O
R

C
O
N
T
R
O
L

U
N
I
T GENERATOR
Model 004673 (7kW)
Model 004674 (12kW)
Model 004675 (15kW)
Rated Maximum Continuous Power Capacity (LP)
7,000 Watts*
12,000 Watts*
15,000 Watts*
Rated Maximum Continuous Power Capacity (NG)
6,000 Watts*
12,000 Watts*
13,000 Watts*
Rated Voltage
120/240
120/240
120/240
Rated Maximum Continuous Load Current
120 Volts
50.0 NG/58.3 LP
100.0
108.3 NG/125.0 LP
240 Volts
25.0 NG/29.2 LP
50.0
54.2 NG/62.5 LP
Main Line Circuit Breaker
30 Amp
50 Amp
60 Amp / 70 Amps*
Phase
1
1
1
Number of Rotor Poles
2
2
2
Rated AC Frequency
60Hz
60Hz
60Hz
Power Factor
1
1
1
Battery Requirement (not included)
Group 26/26R
Group 26/26R
Group 26/26R
12 Volts and
12 Volts and
12 Volts and
350 Cold-cranking
550 Cold-cranking
550 Cold-cranking
Amperes Minimum
Amperes Minimum
Amperes Minimum
Shipping Weight
425 Pounds
525 Pounds
535 Pounds
Dimensions (L x W x H)
48 x 24 x 28-1/4
48 x 24 x 28-1/4
48 x 24 x 28-1/4
* 15 kW on LP fuel requires electrical upgrade kit 04578-0 kit includes
power harnesses and 70 Amp 2-pole circuit breaker
ENGINE
Type of Engine
GH 410
GENERAC OHVI V-TWIN
GENERAC OHVI V-TWIN
Number of Cylinders
1
2
2
Rated Horsepower
14.5 @ 3,600 rpm
26 @3,600 rpm
30 @ 3,600 rpm
Displacement
410cc
992cc
992cc
Cylinder Block
Aluminum w/Cast
Aluminum w/Cast
Aluminum w/Cast
Iron Sleeve
Iron Sleeve
Iron Sleeve
Valve Arrangement
Overhead Valve
Overhead Valve
Overhead Valve
Ignition System
Solid-state w/Magneto
Solid-state w/Magneto
Solid-state w/Magneto
Compression Ratio
8:6:1
9:5:1
9:5:1
Starter
12 Vdc
12 Vdc
12Vdc
Oil Capacity Including Filter
Approx. 1.7 Qts
Approx. 1.7 Qts.
Approx. 1.7 Qts.
Operating RPM
3,600
3,600
3,600
Fuel
Pressure Requirements
Model 004673-0-1
Model 004674-0-1
Model 004675-0-1
11 - 14 inch H
2
O Column
11 - 14 inch H
2
O Column
11 - 14 inch H
2
O Column
Model
004673-2
Model 004675-2
5 - 7 inch H
2
O Column
5 - 7 inch H
2
O Column
Fuel Consumption
Natural Gas
cu.ft./hr.
1000 BTU / 1000 cu. ft.
1/2 Load
66
152
156
Full Load
119
215
220
Liquid Propane
ft
3
/hr(gal/hr)
1/2 Load
30 (0.82)
56 (1.53)
58 (1.58)
Full Load
54 (1.47)
76 (2.08)
88 (2.40)
CONTROLS
Mode Switch
-Auto
Automatic start and stop on utility failure and return. 7 day exerciser.
Cyclic cranking 7 seconds on, 7 seconds rest for 90 seconds maximum.
-Off
Stops unit. Power is removed from controller.
Battery charger will still operate.
-Manual/Test (start)
Start with starter control, unit will stay on. If utility fails,
transfer will take place.
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). Prime (Unlimited Running Time): Unit not recommended for prime power applications. Applicable for supplying electric power in lieu of commercially purchased power. Prime power is
the maximum power available at variable load. A 10% overload capacity is available for 1 hour in 12 hours. (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).* Maximum wattage and
current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above
sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Home Standby 7kW / 12kW / 15kW
Transfer Switch Rating ..................................100/200 Amps
Number of Poles ................................................................2
UL Listed ........................................................Yes, UL 1008
Enclosure................................................NEMA 1 -100 AMP
............................................................NEMA 3R - 200 AMP
Interrupt Rating ................................................10,000 Amps
Maximum Switching Time ..........................160 Milliseconds
Maximum Voltage ..................................................240 Volts
Exercise Time ................Automatic 15 Minutes Each Week
Dimensions H,W,D (Weight)
100A Model 4678 ............................20X14X6 (26 lbs.)
200A Model 4635 ..........................20X14X7.5 (50 lbs.)
HOME STANDBY TRANSFER SWITCH (ORDERED SEPARATELY) Home Standby 7kW / 12kW / 15kW
GENERAC
®
POWER SYSTEMS, INC. P.O. BOX 8 WAUKESHA, WI 53187
262/544-4811 FA X 262/544-4851
© 2004 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Bulletin 0166620SBY / Printed in USA 07.02 rev: 06.04
STANDARD ENGINE & SAFETY FEATURES
High Temperature Automatic Shutdown
Vibration Isolation of Unit to Mounting Base
Low Oil Pressure Automatic Shutdown
12 Volt, Solenoid-Activated Starter Motor
Overspeed Automatic Shutdown (Solid-state)
Air Cleaner
Crank Limiter (Solid-state)
Fan Guard
Oil Drain Extension
Control Console
Rubber-Booted Engine Electrical Connections
Muffler Guard
Fuel Lockoff Solenoid
Flexible Fuel Lines
Secondary Fuel Regulator (N.G. and L.P.)
Critical Exhaust Silencer
Battery Charge Alternator
Battery Trickle Charger
Battery Cables
Main Line Circuit Breaker
Battery Tr