Circuit Protection Circuit Breakers

tance per
Ratings
TS 35
Ratings
TS 35
Pole (ohms)
(amps)
(amps)
131.00
0.1
9104173500
0.1
9120353500
40.00
0.2
9104183500
0.2
9124243500
19.30
0.3
9129813500
0.3
9124263500
10.40
0.4
9124093500
0.4
9124273500
7.10
0.5
9101003500
0.5
9129583500
4.30
0.6
9124113500
0.6
9124283500
3.58
0.7
9129563500
0.7
9124293500
2.50
0.8
9101103500
0.8
9129593500
1.67
1.0
9101203500
1.0
9129613500
1.22
1.2
9101303500
1.2
9129623500
0.61
1.5
9101403500
1.5
9129633500
0.55
1.8
9124143500
1.8
9124333500
0.38
2.0
9101503500
2.0
9129643500
0.24
2.5
9101603500
2.5
9129653500
0.19
3.0
9101703500
3.0
9129663500
0.16
3.5
9124163500
3.5
9124343500
0.09
4.0
9104353500
4.0
9129713500
0.09
4.5
9124173500
4.5
0.061
5.0
9101803500
5.0
9129673500
0.07
5.5
9107833500
5.5
0.041
6.0
9103813500
6.0
9124373500
0.04
6.5
9120043500
6.5
0.034
7.0
9104153500
7.0
9124393500
0.02
8.0
9103003500
8.0
9104673500
0.02
9.0
9104613500
9.0
9124423500
<0.02
10.0
9101903500
10.0
9129683500
<0.02
11.0
9124183500
11.0
<0.02
12.0
9107843500
12.0
9124443500
<0.02
13.0
9124193500
13.0
<0.02
14.0
9107853500
14.0
9124463500
<0.02
15.0
9102003500
15.0
9129693500
<0.02
16.0
9124213500
16.0
9124473500
* Ordering Options - Example
To order CB4201-10 Single Pole Circuit Breaker,
Part No. 9101203501 Current Rating of 1.0 amps Internal Resistance per Pole of 1.67 ohms For TS 35 Without Trip Button
0.8 1
2
3
4
6
8 10
20
30
50 70 100
0.001
0.01
0.1
1
10
100
1,000
10,000
times rated current
T
rip time in seconds
30°C
+23°C
+55°C
M1+
0.05 to 7.5 A
0.8 1
2
3
4
6
8 10
20
30
50 70 100
0.001
0.01
0.1
1
10
100
1,000
10,000
times rated current
T
rip time in seconds
30°C
+23°C
+55°C
M1+
8 to 16 A
Circuit Breaker Trip Curves
Thermal Magnetic Type
Typical time/current characteristics at 23ºC
4200 Series
Single Pole
Double Pole
To manually trip breaker, a plastic or wooden
dowel (0.12 inch diameter) will be needed. 36
Technical Data
Rated voltage & current UL
CSA
VDE
Creepage resistance
Dielectric strength
Insulation resistance
Interrupting capacity
(VDE 0660, Part 101, P-2)
Interrupting capacity; 4201-10
(UL 1077/EN 60934 PC1)
Typical life at 2 x rated current
Shock
Torque
Nm (lb. in.)
Vibration
Temperature range
Corrosion
Humidity
Weight
Wire size (UL)
Accessories
Jumpers
Daisy Chain 50*
Straight CQB**
insulated
Angled CQB**
insulated
Adapter foot (for TS 32 Rail)
Marking Tags
Special print only
Consecutive horizontal
Consecutive vertical
Voltage Ratings
Current
Ratings
AC 250 V, DC 80 V, 50/60 Hz
0.0516 A
AC 250 V, DC 80 V, 50/60 Hz
0.0516 A
AC 250 V, DC 65 V, 50/60 Hz
0.0516 A
PTI 600 to IEC 112
4,000 VAC; IEC 664 & 664 A
> 100 M (DC 500 V)
4201-10
Maximum capacity
0.050.8 A
Self-limiting
12 A
200 A
2.516 A
400 A
Rated current
Rated voltage
Maximum capacity
0.054.5 A
AC 250 V
200 A
58 A
AC 250 V
1000 A
915 A
AC 125 V
1000 A
0.0515 A
DC 65 V
200 A
5,000 operations
25 g (11 ms) to IEC 68-2-27, Test Ea
0.8 (7.1)
5 g (57 to 500 Hz / ±0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc
-30°C+55°C (-22°F+131°F)
96 hours at 5% salt spray, to IEC 68-2-11, Test Ka
240 hours at 95% RH, to IEC 68-2-3, Test Ca
Approximately 60 g per pole
#208 AWG
solid
#2010 AWG
standard
Type
Part No.
BDC 50
9970290000
CQB 2
9970560000
CQB 3
9970570000
CQB 4
9970580000
CQB 10
9970590000
CQB 2
9970600000
CQB 3
9970610000
CQB 4
9970620000
CQB 10
9970630000
AF/TS 32
9102100000
WS 8/5 MC
1640750000***
DEK 5/5
0473460001
DEK 5/5
0473560001
Note: Resistive and inductive loads
(0.05 - 16 A)
*BDC will accommodate 20 A per pin,
20 A total
**CQB will accommodate 18 A per pin,
18 A total; dedicated to 4201 Series
***Please specify horizontal or vertical
print when ordering. Standard
quantity = 144 tags per card.
Internal
Wiring
Diagram
Internal
Wiring
Diagram
CB4201-10
Single Pole
CB4202-10
Double Pole
Dimensions in mm
Dimensions in mm
Note: Part numbers are shown for a single
card of pre-printed tags numbered 1-50. 37
RAIL MOUNTED TERMINAL
BLOCKS: W
-SERIES
CB2211-10
Single Pole
CB2212-10
Double Pole
CB2213-10
Triple Pole
"00" N/C Auxiliary Contact
"02" W/O Auxiliary Contact
"03" N/C-N/O Auxiliary Contacts (double and triple pole only)
"05" N/O Auxiliary Contact
"00" M1, Medium (standard)
"11" F1, Fast (DC only)
"12" M3, Low Resistance
"13" T1, Delayed
Base Part No. (Indicates number of poles)*
9 9 1 2 1 0 0 0 0 3
Auxiliary Contacts Trip Curves
Ordering Options - Example
To order CB2212-10 Double Pole Circuit Breaker with N/O Aux.,
Part No. 9912100003 Current Rating of 1.0 amps Internal Resistance per Pole of 1.1 ohms Trip Curve M1, Medium (Standard) N/C-N/O Auxiliary Contacts
Standard Current Ratings and Typical Internal Resistance Values
Internal
Resistance (ohms)
Current
F1
M1
T1
M3
T2
Rating
fast standard
delayed
low
resistance
thermal
(amps)
acting
delay for
for
standard delay for
for
for DC
AC & DC
AC
AC & DC
AC & DC
0.1
162
92
81
42
77
0.2
39.3
26.1
24.2
11.7
23
0.3
17.5
11.6
10.4
5.6
10.2
0.4
9.2
6.6
6.0
2.9
5.7
0.5
6.8
4.1
3.9
1.75
3.7
0.6
4.2
3
2.7
1.42
2.6
0.8
2.8
1.6
1.53
0.75
1.39
1.0
1.6
1.10
0.98
0.5
0.9
1.5
0.78
0.47
0.42
0.22
0.36
2.0
0.42
0.28
0.24
0.136
0.19
2.5
0.26
0.183
0.17
0.083
0.141
3.0
0.18
0.124
0.12
0.057
0.091
4.0
0.12
0.077
0.073
0.041
0.051
5.0
0.092
0.063
0.055
0.032
0.040
6.0
0.054
0.045
0.039
0.021
0.027
8.0
0.025
0.02
0.02
0.02
0.02
10.0
0.022
0.02
0.02
0.02
0.02
12.0
0.02
0.02
0.02
0.02
0.02
16.0
0.02
0.02
0.02
0.02
0.02
20.0 0.02
0.02 0.02
25.0 0.02
0.02 0.02
32.0 0.02
0.02 0.02
Auxiliary for the 2-pole will be configured: N/C for 1st pole & N/O for 2nd pole.
Auxiliary for the 3-pole will be configured: N/C for 1st pole & N/O for 3rd pole.
*Standard breakers will be calibrated to a M1 trip curve with N/O Auxiliary Contacts.
Ordering
Data
Type: Single Pole - CB2211-10
Type: Double Pole - CB2212-10
Type: Triple Pole - CB2213-10
Internal
Resistance per
Current
N/O Aux.
N/C Aux.
Current
N/O Aux.
N/C-N/O
Current
N/O Aux.
N/C-N/O
Pole
(ohms)
Ratings
Part
Part
Ratings
Part
Part
Ratings
Part
Part
(M1)
(amps)
No.
No.
(amps)
No.
No.
(amps)
No.
No.
92
0.1
9911010000
9911010005
0.1
9912010000
9912010003
0.1
9913010000
9913010003
26.1
0.2
9911020000
9911020005
0.2
9912020000
9912020003
0.2
9913020000
9913020003
11.6
0.3
9911030000
9911030005
0.3
9912030000
9912030003
0.3
9913030000
9913030003
6.6
0.4
9911040000
9911040005
0.4
9912040000
9912040003
0.4
9913040000
9913040003
4.1
0.5
9911050000
9911050005
0.5
9912050000
9912050003
0.5
9913050000
9913050003
3
0.6
9911060000
9911060005
0.6
9912060000
9912060003
0.6
9913060000
9913060003
1.65
0.8
9911080000
9911080005
0.8
9912080000
9912080003
0.8
9913080000
9913080003
1.1
1.0
9911100000
9911100005
1.0
9912100000
9912100003
1.0
9913100000
9913100003
0.47
1.5
9911150000
9911150005
1.5
9912150000
9912150003
1.5
9913150000
9913150003
0.28
2.0
9911200000
9911200005
2.0
9912200000
9912200003
2.0
9913200000
9913200003
0.183
2.5
9911250000
9911250005
2.5
9912250000
9912250003
2.5
9913250000
9913250003
0.124
3.0
9911300000
9911300005
3.0
9912300000
9912300003
3.0
9913300000
9913300003
0.077
4.0
9911400000
9911400005
4.0
9912400000
9912400003
4.0
9913400000
9913400003
0.063
5.0
9911500000
9911500005
5.0
9912500000
9912500003
5.0
9913500000
9913500003
0.045
6.0
9911600000
9911600005
6.0
9912600000
9912600003
6.0
9913600000
9913600003
0.02
8.0
9911800000
9911800005
8.0
9912800000
9912800003
8.0
9913800000
9913800003
0.02
10
9921100000
9921100005
10
9922100000
9922100003
10
9923100000
9923100003
0.02
12
9921120000
9921120005
12
9922120000
9922120003
12
9923120000
9923120003
0.02
15
9921150000
9921150005
15
9922150000
9922150003
15
9923150000
9923150003
0.02
16
9921160000
9921160005
16
9922160000
9922160003
16
9923160000
9923160003
0.02
18
9921180000
9921180005
18
9922180000
9922180003
18
9923180000
9923180003
0.02
20
9921200000
9921200005
20
9922200000
9922200003
20
9923200000
9923200003
0.02
25
9921250000
9921250005
25
9922250000
25
9923250000
0.02
32
9921320000
9921320005
32
9922320000
32
9923320000
Circuit Protection
Circuit Breakers
Thermal Magnetic Type 38
Voltage Ratings
Current
Ratings
277 / 480 VAC (50/60 Hz); 65 VDC
0.1 32 A
277 / 480 VAC (50/60 Hz); 65 VDC
0.1 32 A
250 / 415 VAC / 65 VDC
0.1 32 A
277 VAC / 65 VDC, 1 A
PTI 600 to IEC 112
4,000 VAC; IEC 664 & 664 A
> 100 M (DC 500 V)
Rated current
Rated voltage
Rupture capacity (3 times)
0.05 0.8 A
250 / 415 VAC
400 A
6 32 A
250 / 415 VAC
800 A
Rated current
Rated voltage
Maximum rupture capacity (3 times)
0.1 16 A
277 / 480 VAC
5000 A
20 32 A
277 / 480 VAC
2000 A
0.1 32 A
65 VDC
2000 A
5,000 operations
25 g (11 ms) to IEC 68-2-27, Test Ea
0.6 (5.3)
Auxiliary contact: 0.5 (4.4)
5 g (57 to 500 Hz / ±0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc
-30 +60°C (-22°F +140°F)
96 hours at 5% salt spray, to IEC 68-2-11, Test Ka
240 hours at 95% RH, to IEC 68-2-3, Test Ca
Approximately 60 g per pole
#20 10 AWG
solid
Auxiliary Contact: #20 16 AWG
#20 10 AWG
standard
Type
Part No.
BDC 50, 20 A maximum
9970290000
DEK 5/6
0490360000*
DEK 5/6
0468660001
DEK 5/6
0468760001
Internal Wiring
Diagram
CB2210-10
1 2 3 4 5 6
Note: For Trip Curves, please
reference page 39.
Dimensions in mm
Note: Resistive and inductive loads (0.05 - 16 A)
*Please specify horizontal or vertical print when ordering.
Note:
N/O-Auxiliary contact will be open
during normal state. Aux. will close
when breaker trips.
N/C-Auxiliary contact will be closed
during normal state. Aux. will open
when breaker trips.
Technical Data
Rated voltage & current UL
CSA
VDE
Auxiliary contacts
Creepage resistance
Dielectric strength
Insulation resistance
Interrupting capacity
(VDE 0660, Part 101, P-2)
Interrupting capacity
(UL 1077/EN 60934 PC1)
Typical life at 2 x rated current
Shock
Torque
Nm (lb. in.)
Vibration
Temperature ran