130 kW All input connections in one single area
High coolant temperature shutdown
Low oil pressure shutdown
Low coolant level automatic shutdown
Low fuel pressure
Overspeed automatic shutdown
Adjustable cranking timer
Adjustable exercise timer
Oil drain extension
Cool flow radiator
Closed coolant recovery system
UV/Ozone
resistant
hoses
Watertight state of the art electrical connectors
Mainline circuit breaker
Oil drain extension to frame rail
Radiator drain extension
Battery charge alternator
2 Amp static battery charger
Battery, battery rack and battery cables
Fan and belt guards
Isochronous
governor
Flex fuel line pigtail
STANDARD EQUIPMENT
Innovative design and fully prototype tested
UL 2200 Listed
Solid state frequency compensated voltage regulator
Dynamic and static battery charger
Sound attenuated acoustically designed enclosure
Whisper-Test for low noise level exercise
Acoustically designed engine cooling system
High flow low noise factory engineered exhaust system
State of the art digital control system with H-100

microprocessor control panel
Built-in kW, kVAR and power factor meters
Watertight electrical connectors
Rodent proof construction
High efficiency, low distortion Generac designed alternator
Vibration isolated from mounting base
Matching Generac transfer switches engineered and

tested to work as a system
All components easily accessible for maintenance
Electrostatically applied powder paint
FEATURES
130 kW
60 Hz
Liquid Cooled Gas Engine Generator Sets
Standby Power Rating
GENERAC 6.8L ENGINE
Naturally Aspirated
Gaseous Fueled
Whisper-Test
Low Speed Exercise
65 dB(A) at 23 feet

UL 2200 Listed
COMMERCIAL SERIES
Transfer Switch is sold separately APPLICATION
& ENGINEERING DATA
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).
COMMERCIAL 130 kW
GENERATOR SPECIFICATIONS
TYPE ................................................................................................................Synchronous
ROTOR INSULATION ................................................................................................ Class H
STATOR INSULATION .............................................................................................. Class H
TOTAL HARMONIC DISTORTION ...............................................................................<3.5%
TELEPHONE INTERFERENCE FACTOR (TIF) .................................................................. <50
ALTERNATOR OUTPUT LEADS 3 PHASE ....................................................................4 wire
BEARINGS...........................................................................................................Sealed Ball
COUPLING ...........................................................................................................Gear Drive
LOAD CAPACITY (STANDBY RATING) ..................................................................... 130 kW
EXCITATION SYSTEM ...........................................................................................Brushless
NOTE:
Generator rating and performance in accordance with
ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.
GENERATOR FEATURES
Revolving field heavy duty generator
Quiet drive coupling
Operating temperature rise 120 °C above a 40 °C ambient
Insulation is Class H rated at 150 °C rise
All prototype models have passed three phase short circuit testing
VOLTAGE REGULATOR
TYPE ................................................................................................................... Full Digital
SENSING..................................................................................................................3 Phase
REGULATION ............................................................................................................± 1/4%
FEATURES............................................................................ Built into H-100 Control Panel
V/F
Adjustable

Adjustable Voltage and Gain
CONTROL PANEL FEATURES

TWO FOUR LINE LCD DISPLAYS READ:

Voltage (all phases)
Current (all phases)

Power factor
kW

kVAR
Transfer switch status

Engine speed
Low fuel pressure

Run hours
Service reminders

Fault history
Oil pressure

Coolant temperature
Time and date

Low oil pressure shutdown
High coolant temperature shutdown


Overvoltage

Overspeed

Low coolant level
ATS selection

Not in auto position (flashing light)
Exercise speed



INTERNAL FUNCTIONS:


I2T function for alternator protection from line to neutral and line to line short circuits

Emergency stop

Programmable auto crank function

2 wire start for any transfer switch

Communicates with the Generac HTS transfer switch

Built-in 7 day exerciser

Adjustable engine speed at exerciser

RS232 port for GenLink
®
control

RS485 port remote communication

Canbus addressable

Governor controller and voltage regulator are built into the master control board

Temperature range -40 °
C to 70 °C
ENGINE SPECIFICATIONS
MAKE ...................................................................................................................... Generac
MODEL ......................................................................................................................V Type
CYLINDERS ..................................................................................................................... 10
DISPLACEMENT ..................................................................................................... 6.8 Liter
BORE............................................................................................................................. 3.55
STROKE ........................................................................................................................ 4.17
COMPRESSION RATIO ................................................................................................... 9:1
INTAKE AIR SYSTEM ..............................................................................Naturally Aspirated
VALVE SEATS ........................................................................................................ Hardened
LIFTER TYPE ......................................................................................................... Hydraulic
GOVERNOR
SPECIFICATIONS
TYPE .....................................................................................................................Electronic
FREQUENCY REGULATION ...............................................................................Isochronous
STEADY STATE REGULATION .................................................................................± 0.25%
All functions are factory preset.
Individual parameter adjustments can be made via GenLink
®
.
ENGINE LUBRICATION SYSTEM
OIL PUMP ..................................................................................................................... Gear
OIL FILTER ...................................................................................Full flow spin-oncartridge
CRANKCASE CAPACITY ......................................................................................... 5 Quarts
ENGINE COOLING SYSTEM
TYPE ......................................................................................................................... Closed
WATER PUMP ......................................................................................................Belt driven
FAN SPEED .................................................................................................................. 1950
FAN DIAMETER ..................................................................................................... 26 inches
FAN MODE .................................................................................................................. Puller
FUEL SYSTEM
FUEL TYPE ................................................................................Natural gas, propane vapor
CARBURETOR .....................................................................................................Down Draft
SECONDARY FUEL REGULATOR ........................................................................... Standard
FUEL SHUT OFF SOLENOID .................................................................................. Standard
OPERATING FUEL PRESSURE .......................................................................11 - 14 H2O
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR .....................................................................12V 30 Amp
STATIC BATTERY CHARGER ...............................................................................12V 2 Amp
R