* Must meet current Department of Energy (DOE) minimum efficiency requirements ENERGY CONSERVATION LOAN PROPOSAL REQUIREMENTS
& CONTRACTOR INFORMATION
Clay Electric Cooperative, Inc.
LOAN AMOUNT - Minimum $1,000; Maximum-$5,000; $7,500 for metal roofs.
APPROVED MEASURES - The following measures may be approved by Clay Electric Cooperative
(CEC) for energy efficiency loans.
Heat Pump
Ceiling Insulation
Major Appliances (Minimum Efficiency)
Central Air Conditioner
Floor
Insulation
* Refrigerators
Window Heat Pump
Wall Insulation
* Freezers
Window Air Conditioner
Thermal Windows
Electric or Solar Water Heaters (that reduce
Duct Diagnosis & Repair
Storm Windows
electric consumption)
Duct Insulation
Storm Doors
Dedicated Heat Pump Water Heaters
Electronic/Programmable Thermostats
Thermal Doors
Heat Recovery Units (HRU)
High Reflectance Metal Roofing
Solar Pool Heater
* Must meet current Department of Energy (DOE) minimum efficiency requirements
ENERGY SURVEY REQUIREMENT - Loans to be granted require an energy survey performed by a
CEC representative within the past year.
CONTRACTOR PROPOSAL REQUIREMENTS - Each application for an HVAC system requires a
written proposal signed by a licensed contractor with the following information included with the
proposal:
(a) A load calculation for the purpose of equipment sizing will be required and conducted by
contractor. A copy of load calculation must be submitted with written proposal.
(b) Brand name and all model numbers of indoor and outdoor units to be installed.
(c) Seasonal Energy Efficiency Ratio (SEER) and Heating System Performance Factor (HSPF)
efficiency ratings as listed in the latest American Refrigeration Institute (ARI) manual. Clay
Electrics minimum efficiency requirements as of 1/01/06 are those set forth by the Florida
Energy Code.
(d) "Voltage Reduction Kits" for all scroll compressors rated three (3) tons and larger. This kit is
required if initial startup load is greater than the name plate ratings.
(e) A metal grandstand, insulated platform box or wall hanging assembly is required for split
system air handler installations.
(f) All air handlers will be installed to meet current Florida Energy codes.
(g) Duct system will be inspected for leaks by contractor and proposed repair/replacement costs
itemized separately.
(h) The duct system, when modified, shall meet current Florida Energy Code.
(i) HVAC retrofit in conventional-built homes with less than R-19 attic insulation will be required
to have the insulation level increased to meet the current energy code minimum. Clay Elec-
tric recommends R-30.
(j) Open free air area of return grill(s) coupled with return ductwork shall be properly sized to
meet manufacturing specifications for unit being installed.
-over-
PR-624 01/01/06 REQUIREMENTS FOR LOANS FOR HIGH REFLECTANCE METAL ROOFING - Each application for
high reflectance metal roofing requires the following information included with the proposal:
(a) A reroofing permit whereby the county inspects upon completion of said work.
(b) The metal roofing shall be installed only by a Registered Licensed roofing contractor or State
Certified Roofing Contractor.
(c) Installation shall meet current Florida Building Code criteria.
If you have any questions, please contact the Energy Services Division at (352) 473-8000, Ext. 8263.