Isolated Ground Devices
Isolating the grounding circuit
from harmonic distortion is an
efficient and economical way to
protect sensitive electronics from
operational degradation, disruption,
or damage. Cooper Wiring Devices
has responded to the growing
reliance on clean power systems
with a sophisticated selection of
isolated ground devices. Our line
includes products that cover a wide
range of applications hospital
grade, industrial and commercial
specification grade straight blade
and locking receptacles, transient
voltage surge suppressors, and
compatible plugs and pre-marked
wallplates. All are built for heavy
duty, designed for easy installation,
and manufactured to provide users
with years of dependable electrical
and electronic performance.
L Selecting the right grounding system and
wiring devices ones that completely isolate
the grounding circuit from the transient signals
that can be created by other noise producing
sources will provide protection for your
equipment and information needs.
Install Isolated Grounding Circuits!
L-Intro
-
1
ISOLATED
GROUND
DEVICES
I N D U S T R I A L
C O M M E R C I A L
Isolated Ground Devices
As the use of electronics has grown, Cooper Wiring Devices isolated ground wiring devices
have grown with it . . . from specification and hospital-grade straight blade receptacles and
extra secure Hart-Lock® receptacles . . . to transient voltage surge suppressors . . .
to compatible plugs and wallplates.
Cooper isolated ground products provide users with the security of dependable electrical
and electronic performance, without the expense of often unnecessary power conditioners. L-Intro
-
2
ISOLATED
GROUND
DEVICES
I N D U S T R I A L
C O M M E R C I A L
Isolated Ground Receptacle
Grounding contacts are bonded directly
to the service entrance grounding system.
In the illustration the insulating barrier (A)
isolates the grounding contacts (B) from the
mounting strap (C). The insulated grounding
conductor (D) is bonded to the service entrance
grounding system
How Isolated Ground is Different
(C) Mounting Strap
(D) Insulated Grounding Conductor
Outlet Box
(B) Grounding circuit and
grounding screw
A conventional receptacle is grounded to the
building grounding system at the receptacle.
When mounted in the box, grounding contacts
are connected to the box, fittings, conduit and
all other building ground system components
which can act as a large antenna for EMI and RFI.
Conventional Receptacle
(D) Insulated Grounding Conductor
(A) Insulating
barrier
(B) Grounding circuit and
grounding screw
(C) Mounting Strap
Outlet Box L-1
ISOLATED
GROUND
DEVICES
I N D U S T R I A L
C O M M E R C I A L
TESTING & CODE
COMPLIANCE
UL Listed to 498,
(file no. E3663)
CSA Certified to
C22.2 no.42
(file no. LR7087)
MATERIAL
CHARACTERISTICS
Environmental:
Flammability per
UL 94 requirements,
V2 rated.
Temperature Rating:
-40ºC to 60ºC
except as noted.
Hospital Grade Receptacles
Hospital Grade Receptacles Isolated Ground
G
W
5-15R
5-20R
G
W
G
6-15R
6-20R
G
2 Pole, 3 Wire Grounding
15A 125V, 20A 125V
15A 250V, 20A 250V
Hospital Grade Isolated Ground
Side and Back Wire
Rating
Catalog No.
A
V/AC
NEMA Colors
Duplex
Single*
15
125
5-15R
Gray
IG8200GY
Orange
IG8200RN
IG8210RN
Red
IG8200RD
Ivory
IG8200V
IG8210V
White
IG8200W
20
125
5-20R
Gray
IG8300GY
Orange
IG8300RN
IG8310RN
Red
IG8300RD
Ivory
IG8300V
White
IG8300W
15
250
6-15R
Orange
IG8600RN
IG8610RN
20
250
6-20R
Orange
IG8400RN
IG8410RN
Hospital Decorator Duplex Receptacles Isolated Ground
Rating
A
V/AC
NEMA Colors
Catalog No.
15
125
5-15R
Ivory
IG8262V
Orange
IG8262RN
20
250
5-20R
Ivory
IG8362V
Orange
IG8362RN
*Single receptacles meets all UL, CSA & Federal Specifications, but differ in design and
construction from duplex receptacles.
IG8200
IG8262
IG8210

All terminal (H-N-G) and mounting
screws nickel-plated, triple combination
(slot/Phillips/Robertson) head for
superior corrosion resistance and
maximum installer flexibility.

Long, broad mounting strap helps reach
large panel cutouts for Code compliance.

Automatic grounding system eliminates
need for bonding jumper in grounded
metal enclosure, provides redundant
measure of ground continuity where
jumper used.

Screw-Catch feature on duplex
devices speeds mounting of wallplates.
FEATURES

Exclusive 5-leaf brass line contacts ensure
lowest heat rise, smooth plug blade insertion
and long-term retention.

Rigid, glass reinforced nylon base lends ultimate
strength and superior high heat resistance in
contact carrier.

Unique screw terminal guards provide fast,
easy insulation from conductive surfaces.

Exclusive 0.030" (0.76mm) solid brass, non-
riveted, integral one-piece isolated grounding
shunt system assures ground integrity under
heaviest use isolated from common building
ground.

High impact and chemical-resistant nylon face.

Tapered lead-in slots on back wiring holes assist
in gathering stranded wires for faster, more
secure connections.
4.19"
(106.4mm)
1.75"
(44.5mm)
1.40"
(35.6mm)
1.32"
(33.5mm)
0.88"
(22.4mm)
2.75"
(69.9mm)
1.30"
(33.0mm)
3.28"
(83.3mm)
3.81"
(96.8mm)
3.28"
(83.3mm)
1.29"
(32.8mm)
0.88"
(22.4mm)
2.75"
(69.9mm)
3.28"
(83.3mm)
1.37"
(34.8mm)
0.67"
(17.0mm)
1.72"
(43.7mm)
2.37"
(60.2mm) L-2
ISOLATED
GROUND
DEVICES
I N D U S T R I A L
C O M M E R C I A L
Hospital Grade and
Commercial Specification
Grade TVSS Receptacles

Noise protection against EMI and
RFI standard.

High impact-resistant thermoplastic
mounting strap.

Automatic ground will insure wallplate
grounding in properly grounded metal
enclosure.

Standard 6" (152.4mm) leads,
stripped 0.50" (12.70mm).
FEATURES

Provides surge protection for hot to neutral,
hot to ground and neutral to ground.

Exclusive patented replaceable module restores
expired surge protection without interruption of
power or need to remove and rewire device.

Audible alarm signals when surge protection has
expired; removal of module disables alarm
without interrupting power to receptacle.

Grounding system fully isolated from common
building ground.
Surge Bloc
®
TVSS Devices Isolated Ground
2 Pole, 3 Wire Grounding
15A 125V
20A 125V
Replacement Module
Joules/
Clamping Voltage
MCOV
Color
Catalog No.
400
170J
Ivory
1209V
150V/AC RMS
White
1209W
Blue
1209BL
Red
1209RD
Gray
1209GY
G
W
5-15R
5-20R
G
W
IG1310
3.81"
(96.8mm)
2.69"
(68.3mm)
1.13"
(28.7mm)
3.28"
(83.3mm)
1.74"
(44.2mm)
3.81"
(96.8mm)
2.69"
(68.3mm)
1.13"
(28.7mm)
3.28"
(83.3mm)
1.74"
(44.2mm)
IG1208
1209
Hospital Grade Duplex Receptacle Isolated Ground
Wire Leads
Rating
Clamping
Joules/
Maximum
A
V/AC
NEMA Voltage
MCOV
Surge Current
Color
Catalog No.
15 125
5-15R
400V
170J/
12kA per mode
Blue
IG1308BL
150V/AC RMS
Ivory
IG1308V
Red
IG1308RD
20 125
5-20R
400V
170J/
12kA per mode
Blue
IG1310BL
150V/AC RMS
Ivory
IG1310V
Red
IG1310RD
Commercial Specification Grade Duplex Receptacle Isolated Ground
Wire Leads
Rating
Clamping
Joules/
Maximum
A
V/AC
NEMA Voltage
MCOV
Surge Current
Color
Catalog No.
15 125
5-15R
400V
170J/
12kA per mode
Blue
IG1208BL
150V/AC RMS
Gray
IG1208GY
Ivory
IG1208V
White
IG1208W
20 125
5-20R
400V
170J/
12kA per mode
Blue
IG1210BL
150V/AC RMS
Ivory
IG1210V
White
IG1210W
TESTING & CODE
COMPLIANCE
Meets all
appropriate
UL1449 and UL498
requirements.
Fed. Spec. WC-596,
file #E15058
Meets all CSA
requirements,
C22.2 no. 42, file
#6914 (6233-01)
For replaceable
module: UL file
#E102018
MATERIAL
CHARACTERISTICS
Meets flammability
requirements per
UL94, V2 rated. L-3
ISOLATED
GROUND
DEVICES
TESTING & CODE
COMPLIANCE
Meets all appropriate
UL 1449 (file no.
2369) and UL 498
requirements.
CSA Listed (file no.
LR7087)
MATERIAL
CHARACTERISTICS
Environmental:
Flammability per
UL 94 requirements,
V2 rated.
I N D U S T R I A L
C O M M E R C I A L
Hospital Grade
TVSS Receptacles

Audible alarm indicates bad ground
connection or surge protection has
expired (on models with alarm only).
FEATURES

High impact thermoplastic construction.

8-hole back and side wired.

Shallow depth for easy installation.

Models with LED indicators only to verify
surge protection and ground.
Receptacles with LED Indicators and Switched Alarm
2 Pole, 3 Wire Grounding
15A 125V
20A 125V
G
W
5-15R
5-20R
G
W
3.81"
(96.8mm)
2.70"
(68.6mm)
1.12"
(28.4mm)
3.28"
(83.3mm)
1.31"
(33.3mm)
IG5350HG