g
Durable and fully gasketed die cast aluminum housing
and cover with UV stabilized polycarbonate lens. A full
range of pleasing architecturally inspired powder coated
finishes are available (see below).
Wall mount to standard 3
1
/
2
" or 4" octagonal junction box
or single gang junction box. Surface conduit entry
knockout located on top of housing. Tamperproof hard-
ware is included standard.
E
El
le
ec
ct
tr
ro
on
ni
ic
cs
s
A
AC
C O
Onnllyy - 120/277 VAC dual voltage input with surge
protection is standard on all models.
S
Seellff--P
Poow
weerreedd O
Oppeerraattiioonn - Charging system is micro-
processor driven with software embedded diagnostic
routine and temperature compensation. See specification
sheet C1059 for electronics details. 120/277 VAC input,
surge protection, brownout, AC lockout and low voltage
disconnect features are standard.
O
Op
pe
er
ra
at
ti
in
ng
g
T
Te
em
mp
pe
er
ra
at
tu
ur
re
e
R
Ra
an
ng
ge
e
A
AC
C--O
Onnllyy M
Mooddeellss
Standard Wet Location: -40癋
(-40癈)
to 104癋
(40癈)
Standard Wet Location w/ 2CKT Option: -40癋
(-40癈)
to
104癋
(40癈)
S
Seellff--P
Poow
weerreedd M
Mooddeellss
Standard Wet Location: 32癋
(0癈)
to 104癋
(40癈)
Standard Wet Location w/ Heater Option: -40癋
(-40癈)
to
104癋
(40癈)
I
In
nt
te
el
ll
li
i-
-C
Ch
ha
ar
rg
ge
e
S
Se
el
lf
f-
-T
Te
es
st
ti
in
ng
g
D
Di
ia
ag
gn
no
os
st
ti
ic
cs
s
(
(o
op
pt
ti
io
on
na
al
l)
)
The Intelli-Charge diagnostic/charging platform with
optional self-testing mode automatically runs a one-
minute self-test every 30 days and a 30-minute test on
the sixth and twelfth month. A one-minute or 90-minute
test may be initiated via the push to test switch on the
unit or by activating the appropriate test command on the
optional IR test device.
C
Co
od
de
e
C
Co
om
mp
pl
li
ia
an
nc
ce
e
UL 1598 listed, UL 924 listed
UL wet location listing standard
NFPA 101, NEC, IBC, BOCA, and OSHA illumination
standard
ADA compliant
E
El
le
ec
ct
tr
ri
ic
ca
al
l
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
ns
s
Input Power Requirements
A
AC
C O
Onnllyy M
Mooddeellss
120 VAC: 60 Hz, 0.203A
277 VAC: 60 Hz, 0.087A
A
AC
C O
Onnllyy,, 22 C
Ciirrccuuiitt M
Mooddeellss
120 VAC: 60 Hz, 0.203A
277 VAC: 60 Hz, 0.087A
S
Seellff--P
Poow
weerreedd M
Mooddeellss W
Wiitthhoouutt H
Heeaatteerr
120 VAC: 60 Hz, 0.198A
277 VAC: 60 Hz, 0.088A
S
Seellff--P
Poow
weerreedd M
Mooddeellss W
Wiitthh H
Heeaatteerr
120 VAC: 60 Hz, 0.366A
277 VAC: 60 Hz, 0.148A
B
Ba
at
tt
te
er
ry
y
Maintenance-free sealed nickel metal hydride with
10-year life.
W
Wa
ar
rr
ra
an
nt
ty
y
Three year full electronics warranty
Five year full plus five year prorated NiMH battery
warranty
TYPE:
CATALOG NO.:
Shown: DNBRIC
Architectural White LED Lighting Fixture
Optional Emergency Packages
7.2 Volt, 12 Watt, White LED Lamps
NiMH Battery, Standard Self-Diagnostics Electronics*
Wet Location Listing Standard
O
Or
rd
de
er
ri
in
ng
g
I
In
nf
fo
or
rm
ma
at
ti
io
on
n

(
(E
Ex
xa
am
mp
pl
le
e:
:
D
DN
NB
BR
RI
IC
C)
)
SERIES
D = Diskuss LED
Lighting Fixture
BATTERY
A = AC Only
N = Self-Powered Emergency
Unit with Nickel Metal
Hydride Battery (NiMH)
HOUSING
FINISH
W = White
B = Black
A = Aluminum
G = Gunmetal
BR = Ornamental Bronze
AC = Aged Copper
VG = Velvet Green
N = Nickel
GA = Granite
ACCESSORIES
(order as a separate line item)
ICIR = Intelli-Charge Infra-Red Remote
D
FACTORY INSTALLED
OPTIONS
2CKT1 = Two-Circuit 120/120 VAC
(AC only models)
2CKT2 = Two-Circuit 277/277 VAC
(AC only models)
EX = Special Input Transformer
(specify voltage & frequency)
HR = Heater Option for -40癈 to 40癈 Ambient
T = Self-Testing Diagnostics
TA = Audible Self-Testing Diagnostics
TD = Time Delay
0.8
(2.03 cm)
G
Ge
en
ne
er
ra
al
l
D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
The Diskuss is an architectural indoor/outdoor
lighting product based on the latest technology in
high-output white LEDs. Optional nickel metal
hydride batteries and a diagnostic charger allow for
normally on and emergency lighting in one fixture.
Self-powered models may be wired to allow
independent wall switching when line voltage is
present. Failure of line voltage will cause automatic
emergency transfer. Diskuss is available in a wide
range of decorative finishes to blend with any
setting.
I
Il
ll
lu
um
mi
in
na
at
ti
io
on
n
Illumination is provided by two field-replaceable
white LED modules and a vacuum plated
polycarbonate reflector. The reflector design has
been optimized to produce a 1 footcandle average
illumination along a 6' x 30' path of egress when
placed at a mounting height of 8' AFF. IES
photometric data files are available.
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
The Diskuss housing is designed for direct
mounting to a 3
1
/
2
" octagonal, 4" octagonal or
single gang junction boxes using convenient
keyhole knockouts. The unit may also be connected
to surface conduit via its top-located conduit entry
knockout. A tamperproof fastener for attaching the
cover is provided standard.
D
Di
im
me
en
ns
si
io
on
ns
s
3.6
(9.14 cm)
11.4
(28.96 cm)
0.9
(2.29 cm)
MODEL
DESIGNATOR
IC = Intelli-Charge
Diagnostics
* Self-powered models incorporate the Intelli-Charge diagnostics electronics package.
Self-testing is a factory installed option.
Dimensions are approximate and subject to change.
IC
*Patent Pending*
Chloride is a Philips group brand Specification Data for Diskuss
S
Su
ug
gg
ge
es
st
te
ed
d
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
n
Furnish and install Chloride Systems Diskuss lighting fixture model _____________________________. The unit shall be constructed to meet Underwriters Laboratories,
Inc. Standard 1598 & 924 and must be installed to conform to Article 700 of the National Electrical Code (NEC).
INSTALLATION AND OPERATION AC Only Models Unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, switched, dimmed, photo-celled, or occupancy
sensor power source for normal illumination use. This configuration shall provide area illumination under normal power conditions as would any standard luminaire.
AC Only, 2 Circuit Models - The unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, switched, dimmed, photo celled, or occupancy sensor power source on the
primary input of the fixture for normal illumination use. The isolated secondary input of the unit shall be easily field connected to an emergency AC power source, such as a
generator or inverter equal to the AC connection on the primary input (120/120 or 277/277). This method of installation shall provide emergency illumination in the event the
generator or inverter system is brought on line.
AC/DC Models - The unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, switched, dimmed, photo-celled, or occupancy sensor power source for normal
illumination use. The unit shall have provisions for an isolated low-voltage emergency electrical connection that will accept any DC input ranging from 12 to 48 volts DC from
an emergency battery unit (EBU) remotely located from the fixture and supplied separately. This method of installation shall provide emergency illumination in the event the EBU
senses a brownout or power loss and transfers the DC battery backup voltage to the Diskuss luminaire.
Self-Powered, Nickel Metal Hydride Models - The unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, switched, dimmed, photo-celled, or occupancy
sensor power source on the primary input of the fixture for normal illumination use. The isolated secondary input (emergency input) of the unit shall be easily field connected to
an unswitched 120 or 277 VAC, 60 Hz input and establish the method of monitoring the quality of the AC utility voltage for brownout or power outage conditions. This method
of installation provides a single fixture for normal illumination as well as emergency illumination in a single fixture without the aid of other equipment or components.
ELECTRONICS All self-powered models shall be provided with Chloride's Intelli-Charge diagnostics electronics platform. Intelli-Charge will detect and notify the installer
regarding incorrect wiring of the input transformer primary and will restrict the damaging effects from reaching the printed circuit card. The Intelli-Charge electronics package
shall provide continuous, real-time monitoring of all the critical equipment functions including, but not limited to: line voltage status and condition, charger fault, transfer fault,
battery fault, LED load fault, and notify personnel with a visual indicator sequence. Optional audible diagnostics as well as self-testing diagnostics shall be available from the
factory. The self-testing option shall satisfy the periodic testing requirements as defined in NFPA 101, Life Safety Code, NFPA 70, th