MATERIAL SAFETY DATA SHEET

dth=100%>Yahoo! is not affiliated with the authors of this page or responsible for its content.
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET

EVANS CAPACITOR COMPANY, 72 BOYD AVENUE, EAST PROVIDENCE, RI 02914 401-435-3555
Manufacturers of High Energy Density Capacitors


Evans Capacitor Company
72 Boyd Avenue
East Providence, RI 02914

Telephone Number

401-435-3555

Date Revised: October 8, 2008
PRODUCT IDENTIFICATION
Hybrid
Capacitor tantalum electrolytic capacitor

I. HAZARDOUS INGREDIENTS
Component
CAS#
OSHA PEL
ACGIH TLV
Other
Limits Max.
%
Sulfuric Acid
7664-93-9
1mg/m
3
1mg/m
3


5
Tantalum Metal
7440-25-7
5mg/m
3
5mg/m
3


90
Ruthenium Oxide
32740-79-7
not hazardous


1


II. PHYSICAL DATA

Maximum Operating Temperature 125癈 (see product literature)




III. FIRE AND EXPLOSION DATA

Capacitors can spark if discharged into a short-circuit and the case can burst if subjected to excessive voltage or
temperature.

IV. HEALTH HAZARD DATA

Electrocution Risk. Avoid personal contact with high-voltages which may be present on charged capacitors.
Electrolyte contains sulfuric acid. Exposure to electrolyte is not possible unless case or seal is compromised. Avoid
conditions which can burst case (see Section III). Sulfuric acid can cause serious burns to all tissues contacted.
Sulfuric acid is exceedingly dangerous to the eyes. Protect skin and eyes from contact. Overexposure from
inhalation may lead to pulmonary edema.. Long exposures are claimed to lead to respiratory infections, emphysema,
and digestive disturbances. Sulfuric acid not normally present outside case. To avoid exposure, do not open case.

Emergency First Aid Flush exposed skin and eyes immediately with cold water. Seek physician, especially if
eyes are exposed.


V. SPECIAL INSTRUCTIONS

Avoid exposure to finely divided tantalum. Normal exposure to tantalum metal is not hazardous. Do not cut, drill,
puncture, grind, or machine case. Do not incinerate.