Lithium-Ion Battery Cell Specification

>
Lithium-Ion Battery Cell Specification


Lithium-Ion Battery Cell
Specification



Classification:
3.6V 2200mAh 18650
Li-ion Cell

Cell Type:
LC-18650H2





AA Portable Power Corp
Technology Department
Battery Technical Service Department

Prepared
Louis

Checked
Louis

Approved
Louis








Title
Li-ion Battery Specifications (Steel)
File No:
HYB/QP-09-E167-NH
Version
NO:B/0
Control code0709047


Title
Li-ion Battery Specifications (Steel)
Revision History

Revision Date
Originator
Description
B/0 2007-09-20
Engineering Center
Original Release































































File No:
HYB/QP-09-E167-NH
ICR18650NH Engineering Center
Title
Li-ion Battery Specifications (Steel)
Page
1/11
1. Scope
This Specification is applied to rechargeable lithium ion battery cell of the following mentioned type for various
applications in mobile communication devices and portable power systems.
2. Cell Classification and Type
2.1 Cell Classification Lithium Ion Battery Cell
2.2 Cell TypeICR18650NH

3. Standard
The specification is based on the technical specification of GB/T18287-2000 UL1642 and IEC61960.
4.
Nominal Specification


Item Specification
Remarks
4.1
Typical capacity
2200mAh
0.2 C
5
A discharge
4.2 Minimum
Capacity
2150mAh

4.2 Nominal Voltage
3.7V

4.3 Discharging Voltage (Min)
2.75V

4.4 Charging Voltage (Max.)
4.2±0.03V

4.5 Charging CurrentStd.
0.5 C
5
A
4.6 Discharging CurrentStd.
0.2 C
5
A
4.7 Charging Current (Fast
1 C
5
A
0 ~ 40
°C, <95%RH
4.8 Discharging CurrentFast
1 C
5
A
4.9 Discharging CurrentMax.
2 C
5
A
4.10 Internal Impedance 70m

AC impedance 1kHz
Difference among cells
should be less than 10m

in a shipment.
4.11 Weight
45.0±2.0g

Diameter 18.0±0.2mm
4.12 Outline dimension (see
figure)
Length
64.8±0.5mm

Min 1 Month
-20 ~ +60
°C,
<75%RH*

Min 3 Months
-20 ~ +45
°C,
<75%RH*

4.13 Battery cell storage and
transportation environment and
temperature ranges
Min 12 Months
-20 ~ +25
°C,
<75%RH*

Initial status of cell 3.80V and
50% of charge, the capacity lost
during shipment < 20%.
Capacity recover rate > 80%.


File No:
HYB/QP-09-E167-NH
ICR18650NH Version
No:B/0 Engineering
Center Title
Li-ion Battery Specifications (Steel)
Page
2/11
5. Electrical Characteristics

Item Test
Method
Performances
5.1 Full Charge
5.2 Capacity


5.3 Cycle life

5.4 Capacity retention

The charger supplies 1C constant current until battery
voltage reaches 4.2V then be changed at constant
voltage of 4.2V while tapering the charge current to less
than or equal to 0.01 C. Charging time is 3.0 hours in all. Within 1 hour after fully charged, discharged at 0.2C
continuously down to 2.75V. Within 1 hour after fully charged, discharge at 1C
continuously down to 2.75V.
A battery unit shall be repeated 300 charge/discharge
cycles, charged at CC-CV (0.5 C - 4.2V) for 3. 0 hours,
discharged at 0.5C continuously down to 2.75V Cut-off
Voltage. Measure discharge capacity.
HYB guarantee that the residual capacity of 2 cells in
series without circuitry is over than 80% after 300 cycles.
(Capacity testing after 300 cycles will be performed under
condition of 0.5C charging and 0.2C discharging)

After fully charged, stored for 28 days at 20
°C, then for 1
hour between 20
°C to 25°C and continuously discharge
at 1C to 2.75V.




More than 300min

More than 54min

80% capacity






Capacity retention rate

85%
Minimun Capacity
The minimum capacity is in the specifications table. The term refers to the capacity when the charged cells are
discharged to the cut-off voltage for 5 hours at 20
°C±5°C. Typical Capacity
Typical capacity refers to the median value of the capacity when a battery cell is discharged to the cut-off voltage
with the current of 0.2 C at 20
°C±5°C. Limit Charge Voltage
Charged cells with constant current to reach a voltage value, then keep the voltage constant and continue to charge
them. The voltage is referred to as limited charge voltage. The value is 4.2V. Cut-off Voltage
Cut-off Voltage Refers to the end voltage when a battery cell is discharged to reach. The value is 2.75V.







File No:
HYB/QP-09-E167-NH
ICR18650NH Version
No:B/0 Engineering
Center Title
Li-ion Battery Specifications (Steel)
Page
3/11
6. Temperature Adaptability

Item Test
Method
Performances
6.1 Capacity at different temperature




6.2 Discharge at constant
temperature /humidity



6.3 Vibration





6.4 Shock


6.5 Free fall



Measure capacity with constant discharge current of
0.2 C to 2.75V cut-off at each temperature after
complete charge at 20.


Percentage as an index of the capacity compared with
100% at 20.Keep the battery at 40 and 90%RH,
goal is 95%, for 48 hrs and then discharge at 1C to
2.75V Cut-off Voltage.

The battery cell will be vibrated 10 sine sweeps in
three mutually perpendicular directions with amplitude
of 0.19-0.38mm and changing frequency between 10
and 55Hz. The rate of scanning frequency is from 10H
Z

to 55 H
Z
with the rate of 1 H
Z
per min.

The battery cell shall be accelerated 1000 times at
100m/s
2
for durations of 16mS.

The battery cell will be dropped free one time in three
mutually perpendicular directions from the height of
1.0m onto a hard board with the thickness of 20mm.
Minimum capacity:
60% at -20
80% at 0
95% at 55

The battery cell shall not
rupture, smoke, catch fire,
vent or leak. The time of
discharge is no less than 36
min.
The battery cell shall not
rupture, smoke, catch fire,
vent or leak. The voltage is
no less than 3.6V.


The battery cell shall not
rupture, smoke, catch fire,
vent or leak.
The battery cell shall not
rupture, smoke, catch fire,
vent or leak.

7. Safety Characteristics

Item
Test Method
Performances
7.1 Short Circuit




7.2 Over charge

The battery cell is to be short-circuited by connecting
the positive and negative terminals of the battery with
an external load of less than 100 m until the surface
temperature decrease 10 degree from the highest
point.
The battery cell charged completely will be charged
continuously for 8hrs with the external power supply of
the limit voltage of 4.6V and the current of 3A.

The battery cell shall be no
fire, somke or explosion.



The battery cell shall be no
fire, smoke or explosion.

File No:
HYB/QP-09-E167-NH
ICR18650NH Version
No:B/0 Engineering
Center Title
Li-ion Battery Specifications (Steel)
Page
4/11
7.3 Over discharge



7.4 Crush







7.5 Impact




7.6 Heating

After complete charge, the battery cell will be
discharged to end voltage. Then connect with
external load of 30 discharge for 24hrs.

A charged battery cell is to be crushed between two
flat surfaces. The force for the crushing is to be
applied by a hydraulic ram with a 1.25 inch (32mm)
diameter piston. The crushing is to be continued
until a pressure reading of 17.2Mpa is reached on
the hydraulic ram, applied force of 13kN.Once the
maximum pressure has been obtained it is to be
released.
Drop a 10kg hammer from a height of 1m onto the
cell that is placed on a flat surface. (The largest
surface of the battery cell shall be perpendicular to
the flat surface.)

Place the battery cell in an oven. The temperature
of the oven is to be raised at a rate of 5±2/min
to a temperature of 150±2, and remain for
10min at that temperature.
The battery cell shall not
rupture, smoke, catch fire,
vent or leak.

The battery cell shall not
rupture or catch fire.






Deformation of the battery cell
is allowed, but there shall be
no fire or explosion.


The battery cell shall be no fire
or explosion.
8 Standard Test Conditions
8.1 Test Condition
Unless otherwise specified, all tests stated in this Product Specifications shall be conducted under the following
atmosphere conditi