Smart Online Expandable Rack / Tower UPS System

deal solution and provide a custom configuration.
Contact a Tripp Lite Product Specialist
DESCRIPTION
Tripp Lite's high voltage Smart Online SU3000RTXL3UHV on-line, double conversion UPS protects critical server, networking or
telecommunications equipment from blackouts, voltage fluctuations and surges. Multi-use form factor occupies only 3 rack spaces (3U) in
standard 19 inch rackmount configuration and includes tower stands to support upright placement. Large capacity 3kVA / 2400 watt UPS
continuously converts incoming AC to DC, then back to perfect sine wave AC output at selectable 200/208/220/230/240V AC (+/-2%) output.
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other
UPS types. True sine wave output and zero transfer time offers guaranteed compatibility with all high-voltage equipment types. Includes 6
outlets arranged in two individually switchable load banks plus 2 L6-20 outlets. These outlet banks can be independently controlled via
software interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment.
Battery support can be extended indefinitely through the addition of external 2U or 3U rackmount battery packs (part# BP72V15-2U limit 1 /
BP72V28-3U multi-pack compatible). Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended
shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's WatchDog Service Monitoring/Reboot
Software.
KEY BUYING POINTS
True on-line, double conversion UPS provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
Accepts input voltages between 160 and 275 (130 to 275 at loads under 70%), regulating output to selectable 200/208/220/230/240V
+/-2%
3000VA / 2400 watt power capacity with 8 total outlets (6 NEMA6-15/20R & 2 NEMAL6-20R)
Standard internal battery set provides 17 minutes runtime at half load
Expandable runtime with multiple external battery packs (part# BP72V15-2U limit 1 / BP72V28-3U multi-pack compatible)
Innovative design makes unit adaptable for rackmount, tower, or stacking applications
Uses only 3 rack spaces (3U) in standard 19 inch rack
DB9 serial port for network interface; SNMP compatible
Slot for optional SNMP/web card (part# SNMPWEBCARD)
PowerAlert unattended shutdown software and 6 ft. network cable included
Compatible with Tripp Lite's Watchdog Service Monitoring/Reboot Software
Fault tolerant auto-bypass maintians continuous utility output to connected equipment, even in cases where the UPS is overloaded or
suffers an internal failure that requires service
Diagnostic LEDs
Battery replacement door Mounting hardware included for 4 post rack enclosures, 2 post telecom rack compatible with separate purchase 2POSTRMKITWM
accessory
$250,000 Ultimate Lifetime connected equipment insurance
2 year manufacturer's product warranty
TYPICAL APPLICATIONS
Ideal for protection of critical high-voltage equipment in server rooms, internetworking closets and telecommunications systems in
rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers,
bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.
OPTIONS & ACCESSORIES
External battery packs:
BP72V15-2U
(limit 1),
BP72V28RT-3U
(multi-pack compatible)
SNMP accessories:
SNMPWEBCARD
,
ENVIROSENSE
AS400/iSeries Shutdown Cable Kit:
AS400 CABLE KIT
Dataline protectors:
DNET1
,
DTEL2
,
DCATV
Rack enclosures:
Rack Systems
Power Distribution:
PDU12IEC
Two Post Rackmount Kit:
2POSTRMKITWM
Extended warranties: 3 Year
WEXT3-2200-3000
, 5 Year
WEXT5-2200-3000
PACKAGE INCLUDES
SU3000RTXL3UHV Rack-Tower UPS System
PowerAlert Software and cabling
Mounting hardware for 4 post rackmount enclosures / tower stands included
Warranty information
Instruction manual
COMPLETE SPECIFICATIONS
SYSTEM OVERVIEW
System overview:
Online, high-voltage double conversion 3U rack / tower UPS system continuously maintains
near-perfect output power for critical internetworking and telecommunications equipment.
Completely regenerates input power into perfectly regulated sine wave output free of
harmonic distortion, fast electrical impulses and frequency fluctuations. Maintains output
within 2% of selected 200/208/220/230/240V nominal during brownouts as low as 130V and
overvoltages to 275V. Supports enhanced monitoring of UPS and line power conditions via
DB9 serial port, included PowerAlert monitoring software and complete cabling. Includes slot
for SNMPWEBCARD and 2 individually controllable output load banks. Runtime is
expandable with external battery packs.
Voltage compatibility:
208V AC
Frequency compatibility:
50/60 Hz compatible
OUTPUT
Output volt amp capacity (VA):
3000
Output watt capacity (watts):
2400
Output nominal voltage:
208V AC (200/220/230/240V)
Output voltage regulation:
Maintains full-time sine wave output within 2% of selected nominal voltage, less than 5% total
harmonic distortion
Output frequency regulation:
Regulates line frequency to 50/60Hz +/- 0.05Hz Outlet quantity / type:
6 NEMA 6-15/20R, 2 NEMA L6-20R
Customized load management receptacles:
2 individually controllable load banks support load shedding and remote reboot on demand of
locked network devices. Controllable via PowerAlert software to switch off optional loads, like
monitors, to increase available runtime for servers and other critical devices. (Bank A
consists of 4 outlets / Bank B consists of 2 outlets)
Overload protection:
Via 25A input breaker
INPUT
Maximum input amps:
14.9 / 14.3 / 13.1 / 12.6 / 12.1 Amps (depending on voltage) / 2844 watts
Input connection type:
NEMA L6-20P
Input cord length:
10 ft. 14 gauge
Recommended electrical service:
15A 200-240V
BATTERY
Full load runtime:
Internal batteries 6 min. (3000VA)
Half load runtime:
Internal batteries 17 min. (1500VA)
Expandable battery runtime:
Supports extended runtime with optional external battery pack BP72V15-2U (limit 1),
BP72V28-3U (multi-pack compatible)
DC system voltage:
72 V DC
Typical battery lifespan:
3-6 years, depending on usage
Battery recharge rate:
2-4 hours to 90%
VOLTAGE REGULATION
Voltage regulation description:
On-line, double-conversion power conditioning maintains output within 2% of
200/208/220/230/240 volts at all times
Overvoltage correction:
Maintains output during overvoltages to 275V AC
Brownout correction:
Maintains output during undervoltages to 160V AC
Severe brownout correction:
At load levels less than 70%, UPS maintains output during undervoltages to 130V AC
LEDS ALARMS & SWITCHES
Front panel LEDs:
6 LED STATUS DISPLAY: line power (green), online (green), bypass (yellow), on battery
(green), overload (red), battery low (yellow)
4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%)
Alarms:
Multi-function audible alarm offers notification of UPS start, backup operation, low battery
warning, overload, UPS fault and remote shutdown
Switches:
Includes main power off/on switch, plus 1 switch to select battery charge / load level display
SURGE / NOISE SUPPRESSION
AC surge suppression:
2670 joules
AC suppression response time:
Instantaneous
EMI / RFI AC noise suppression:
Yes
PHYSICAL
Shipping weight (lbs):
90.3
Shipping weight (kg):
41.0
Unit weight (lbs):
74.9
Unit weight (kg):
34.0
Unit Dimensions (HWD/in):
5.2 x 17.3 x 19.8
Unit Dimensions (HWD/cm):
13.3 x 44.5 x 50.3
Shipping Dimensions (HWD/in):
13.3 x 23.8 x 25.7
Shipping Dimensions (HWD/cm):
33.8 x 60.5 x 65.3 Material of construction:
Steel
Form factors supported:
Rack/Tower (3U)
Cooling method:
Built-in cooling fan
Battery Access:
User replaceable, hot swap battery replacement supported via front access panel
ENVIRONMENTAL
Operating Temperature:
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
Storage Temperature:
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
Relative Humidity:
0 to 95%, non-condensing
Line mode BTU/hr. (Max.):
1117 btu/hr. (88% efficiency line mode)
Battery mode BTU/hr. (Max.):
1224 btu/hr. (87% efficiency battery mode)
COMMUNICATIONS
Network monitoring port:
One built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact
closure basic monitoring capability
Software and cabling included:
Yes, includes PowerAlert software CD-ROM and complete cabling
SNMP compatibility:
Yes, includes slot for optional SNMPWEBCARD accessory (#SNMPWEBCARD)
WatchDog compatibility:
Yes, compatible with Tripp Lite's Watchdog Monitoring/Rebooting Service to restore
operation to locked equipment through soft reboot of application / OS or hard power off/on
reboot of connected equipment
LINE / BATTERY TRANSFER
Transfer time from line power to battery
mode:
Zero, online UPS continuously converts incoming AC to DC, then back to AC. When
commercial power is interrupted, UPS maintains continuous output from battery reserves
with absolutely no disruption in output AC power.
Low voltage transfer to battery power:
Maintains continuous operation during undervoltages as low as 160V (130V at load levels
under 70%). Below this switchover point, output is supported from battery derived AC power.
High voltage transfer to battery power:
Maintains continuous operation without using battery power during overvoltages to 275V.
Above this point, output is supported from battery derived AC power.
CERTIFICATIONS
Certifications:
UL1778 (USA), cUL (Can